English introduction Congratulations on your purchase and welcome to Philips! To fully benefit from the support that Philips offers, register your product at www.philips. com/welcome. With this new bedroom air purifier you breathe cleaner air. For the best results, place the bedroom air purifier in a room where you spend most of your time, e.g.
Page 7
If the mains cord is damaged, you must have it replaced by Philips, a service centre authorised by Philips or similarly qualified persons in order to avoid a hazard.
Make sure all filters are properly installed before you switch on the appliance. Only use the original Philips filters specially intended for this appliance. Do not use any other filters. Avoid knocking against the appliance (the air inlet and outlet in particular) with hard objects.
Page 9
English Place your fingers in the recesses of the side panels and gently pull the bottom of the front panel towards you. Then lift the hooks at the top of the panel out of the top of the appliance. To remove the pre-filter, grab the two projections and pull the filter towards you.
Page 10
Place filter 1 (pre-filter) in the appliance. Note: AC4004: make sure the multi-care filter is attached to the back of the pre-filter. Note: Make sure that the side with the two projections points towards you.
English , The power-on light and one of the AIR QUALITY lights on the control panel goes on. AC4004: AiR QUAliTY lights Colour Air quality Blue very good Deep purple good Purple fair AC4002: AiR QUAliTY lights Colour Air quality...
English Note: When the appliance is operating in another mode and you want to activate the auto mode, simply press the AUTO button. , The AUTO light and one of the FAN SPEED lights go on. The FAN SPEED light indicates at which fan speed the appliance is operating. Note: When the air quality is very good and the fan speed operates at a very low fan speed, the FAN SPEED light for the lowest speed level does not go on.
English When you choose a fan speed manually (see section ‘Fan speed’ in this chapter). In this case, one of the FAN SPEED lights, the TIMER light and one of the HOUR lights are on. In combination with the SLEEP mode (see section ‘Sleep mode’ in this chapter).
English extra sensitive sensitive standard The air quality sensor is set to standard sensitivity. You can adjust the sensitivity of the air quality sensor in the following way: If the appliance is already plugged in, unplug the appliance and wait for a few minutes.
Page 15
To remove the pre-filter, grab the two projections and pull the filter towards you. AC4004 only: remove the multi-care filter from the back of the pre- filter. Wash the pre-filter under a running tap. If the pre-filter is very dirty, use a soft brush to brush away the dirt.
English To reattach the front panel, insert the two hooks into the top of the appliance first (1). Then push the panel against the body of the appliance (2). Put the plug in the wall socket. Press and hold the reset button for filter 1 (the button below the filter cleaning light) for 2 seconds to reset the appliance.
This air purifier is also equipped with the Healthy air protect lock to ensure that the filters are in optimal condition when the appliance is operating. When you do not replace filter 2 (AC4004 only), filter 3 and/or filter 4, the appliance stops operating and the appliance is locked. When the appliance is locked, the filter replacement light of the filter concerned and the ’REPLACE FILTER’...
To remove filter 1 (pre-filter), grab the two projections and pull the filter towards you. AC4004 only: remove filter 2 (multi-care filter) from the back of the pre-filter.
Page 19
Note: Make sure that the side with the tag points towards you. Put filter 3 (activated carbon filter) back into the appliance. AC4004 only: reattach filter 2 (multi-care filter) to the back of filter 1 (pre-filter). Note: Make sure that the front of the multi-care filter points towards the pre-...
Page 20
English Put filter 1 (pre-filter) back into the appliance. Note: Make sure that the side with the two projections points towards you. Note: Make sure that all hooks are properly attached to the appliance. To reattach the front panel, insert the two hooks into the top of the appliance first (1).
By doing this, you help to preserve the environment. guarantee and service If you need information or if you have a problem, please visit the Philips website at www.philips.com or contact the Philips Consumer Care Centre in your country (you find its phone number in the worldwide guarantee leaflet).
Page 22
HEPA filter, activated carbon filter, multi-care filter (AC4004 operating for a long time. only), pre-filter. The multi-care filter (AC4004 only) has to be attached to the back of the pre-filter. The air quality sensor is wet. The humidity level in your room is high and causes condensation.
Page 23
Contact the Consumer Care Centre in your country (you find its ring flashes blue, all other phone number in the worldwide guarantee leaflet). If there is no Consumer lights are out. Care Centre in your country, go to your local Philips dealer.
Need help?
Do you have a question about the AC4004 and is the answer not in the manual?
Questions and answers