COMBINATION OF INDOOR AND OUTDOOR UNITS INDOOR UNIT SERVICE MANUAL Outdoor unit Heat pump type Indoor unit SUZ- Service Service Ref. KA25VA3.TH KA35VA3.TH KA50VA3.TH KA60VA3.TH KA71VA3.TH Manual No. — — — — SLZ-KA25VA(L).TH — — — SLZ-KA35VA(L).TH — — — —...
PARTS NAMES AND FUNCTIONS SUZ-KA25VA3.TH SUZ-KA35VA3.TH Air inlet (back and side) Piping Drain hose Air outlet Drain outlet SUZ-KA50VA3.TH Air inlet SUZ-KA60VA3.TH (back and side) SUZ-KA71VA3.TH Piping Drain hose Air outlet Drain outlet Model SUZ-KA·VA3.TH 'UDLQ VRFNHW OCH530A...
NOISE CRITERIA CURVES SUZ-KA25VA3.TH SUZ-KA35VA3.TH FUNCTION SPL(dB(A)) FUNCTION SPL(dB(A)) FAN SPEED LINE FAN SPEED LINE COOLING COOLING High High Med. Med. HEATING HEATING NC-70 NC-70 NC-60 NC-60 NC-50 NC-50 NC-40 NC-40 NC-30 NC-30 NC-20 NC-20 NC-10 NC-10 1000 2000 4000...
OUTLINES AND DIMENSIONS SUZ-KA25VA3.TH SUZ-KA35VA3.TH Unit: mm REQUIRED SPACE Basically open 100mm or more without any obstruction in front and on both sides of the unit. Drain hole 42 Air in Air in Open two sides of left, right, or rear side.
SUZ-KA50VA3.TH Unit: mm SUZ-KA60VA3.TH Open as a rule REQUIRED SPACE SUZ-KA71VA3.TH 500mm or more if the front and both sides are open 417.5 Air in 100mm or more 200mm or more if there are obstacles to both sides Air in Air out 2-Oval holes 10 21 Open as a rule...
Page 24
11-3-3. Self-diagnosis <PAR-21MAA> When a problem occurs to the air conditioner, the indoor and outdoor units will stop, and the problem is shown in the remote controller display. [CHECK] and the refrigerant address are displayed on the temperature display, and the error code and unit number are displayed alternately as shown below.
When the error history is reset, the display will look like the one shown below. Press the button ( in the picture in the previous page) twice ON/OFF However, if you fail to reset the error history, the error content will be displayed again. within 3 seconds.
Page 26
11-3-6. Self-diagnosis <Wireless remote controller> <In case of trouble during operation> :KHQ D PDOIXQFWLRQ RFFXUV WR DLU FRQGLWLRQHU ERWK LQGRRU XQLW DQG RXWGRRU XQLW ZLOO VWRS DQG RSHUDWLRQ ODPS EOLQNV WR LQIRUP XQXVXDO VWRS < Malfunction-diagnosis method at maintenance service> [Procedure] 3UHVV WKH &+(&.
Refer to the following tables for details on the check codes. [Output pattern A] Beeper sounds Beep Beep Beep Beep Beep Beep Beep OPERATION · · · Repeated INDICATOR lamp flash pattern Approx. 2.5 sec. 0.5 sec. 0.5 sec. 0.5 sec.
11-4. TROUBLE CRITERION OF MAIN PARTS SUZ-KA25VA3.TH SUZ-KA35VA3.TH SUZ-KA50VA3.TH SUZ-KA60VA3.TH SUZ-KA71VA3.TH arts name Chec method and criterion Figure Defrost thermistor (RT61) Fin temperature Measure the resistance with a tester. thermistor (RT64) Ambient temperature Refer to 11-6. Test point diagram and voltage 11-6-1. (KA25 35 50) or thermistor (RT65) 11-6-2.
Pull the terminal while pull out the terminal pushing the locking slowly. Locking lever lever. Connector SUZ-KA25VA3.TH SUZ-KA35VA3.TH OUTDOOR UNIT NOTE: Turn OFF power supply before disassembling. 1. Removing the cabinet Photo 1 (1) Remove the screw fixing the service panel.
Page 37
OPERATING PROCEDURE PHOTOS 2. Removing the inverter assembly, inverter P.C. board Photo 3 (1) Remove the cabinet and panels. (Refer to procedure 1.) (2) Disconnect the lead wire to the reactor and the following con- Screws of the nectors: relay panel <Inverter P.C.
Page 38
OPERATING PROCEDURE PHOTOS 5. Removing outdoor fan motor Photo 6 (1) Remove the cabinet and panels. (Refer to procedure 1.) Outdoor heat (2) Disconnect the following connectors: exchanger tempera- <Inverter P.C. board> ture thermistor CN932 (Fan motor) (3) Remove the propeller nut. (Photo 7) (4) Remove the propeller.