1.6 1. SpaceWise Technology Industry Luminaire Philips luminaires with wireless SpaceWise Technology are stand-alone LED lighting systems with integrated high bay occupancy sensing and daylight harvesting, designed specifically to meet the lighting control needs of an industrial space. With this technology, installers can group multiple luminaires and activate automated dimming behaviors using a SpaceWise remote control.
The cover is a plastic circular ring sticker that can be peeled and applied on the lens of the sensor. In any instance the view of the sensor should not be blocked with any obstructions. Philips Lighting North America...
Also check that the first luminaire is in the right position and oriented correctly with respect to the edge of the isle. Refer to section 12 (walk test) for details on testing the coverage area of the sensor. Note the luminaire needs to be grouped before performing the walk test. Philips Lighting North America...
Install luminaires per manufacturer installation instructions and ensure sensors from adjacent luminaires are not positioned next to one another. 3. SpaceWise Remote (IRT 9090) The SpaceWise remote is the only tool required by the installer to group the SpaceWise Technology Luminaires together and to change any default configuration settings. A set of 2 AAA batteries of 1.5V each are supplied with the remote.
Page 7
SpaceWise for Industrial Applications v. 1.6 Philips Lighting North America...
“add.” Repeat step for adding all the luminaires in the group. Point to any of the luminaires added in All the luminaires in the group the group and press “close.” will go to 50% light level. Philips Lighting North America...
Page 9
Refer to the FAQ section for additional information on how to correct non responsive luminaires. Philips Lighting North America...
(mode# 6) and since the behavior varies for each mode, it is recommended to select the mode that closely reflects the installed application space. See the SpaceWise Design Guide (www.philips.com/spacewise) for details. Application...
“mode.” blinking. While the LED is still blinking red, enter Red LED on remote will stop the number for the preferred mode (see blinking. list at step 5). Eg. Select “8” for warehouse comfort application mode. Philips Lighting North America...
Page 12
Point to any of the luminaires in the Red LED on remote will start group and press “lock.” blinking. The luminaire will FLASH twice. Wait for LED to stop blinking (apx. 10 Group is ready for normal seconds) then press “send.” operation. Philips Lighting North America...
Red LED on remote will stop Wait for LED to stop blinking (apx. 10 blinking. seconds). The luminaire will FLASH twice Point remote to any of the luminaires and group light level will go to and press “send.” 50%. Philips Lighting North America...
Page 14
50% light level to permanent 77% light level. If you repeat the step down sequence again then upon careful observation you will see the subtle change in light level from 77% to 66%. Philips Lighting North America...
Page 15
Point to any of the luminaires in the Red LED on remote will start group and press “lock.” blinking. The luminaire will FLASH twice Wait for LED to stop blinking (apx. 10 and group is ready for normal seconds) then press “send.” operation. Philips Lighting North America...
4. Point remote to any luminaire and press Red LED on remote will start “unlock,” once. blinking. Red LED on remote will stop Wait for LED to stop blinking (apx. 10 blinking. seconds). Philips Lighting North America...
Page 17
To stop the zone creation process, point All the luminaires in the group to any of the luminaires added in the will go to 50%. zone and press “close.” Philips Lighting North America...
Page 18
“zone”. Point to the same luminaire and press The entire zone turns on or off “on” or “off.” accordingly. To stop the test process, point to the same luminaire and press “close.” Philips Lighting North America...
Red LED on remote will start blinking. While the LED is still blinking red, enter Red LED on remote will stop the numbers: blinking. “10”: Enable occupancy sensing “12”: Disable occupancy sensing (lights will stay at 100%) Philips Lighting North America...
Page 20
Point to any of the luminaires in the Red LED on remote will start group and press “lock.” blinking. The luminaire will FLASH twice. Wait for LED to stop blinking (apx. 10 Group is ready for normal seconds) then press “send.” operation. Philips Lighting North America...
50%. Press “daylight” button. Red LED on remote will start blinking. While the LED is still blinking red, enter Red LED on remote will stop the numbers: blinking. “1”: Disable daylight sensing “2”: Enable daylight sensing Philips Lighting North America...
Page 22
Point to any of the luminaires in the Red LED on remote will start group and press “lock.” blinking. The luminaire will FLASH twice. Wait for LED to stop blinking (apx. 10 Group is ready for normal seconds) then press “send.” operation. Philips Lighting North America...
When the arrow keys are and adjust the group light level to the pressed, red LED on remote will required level using the dimming “up” or keep blinking. “down” arrow keys The group will dim up or down accordingly. Philips Lighting North America...
Page 24
Point to any of the luminaires in the Red LED on remote will start group and press “lock.” blinking. The luminaire will FLASH twice. Wait for LED to stop blinking (apx. 10 Group is ready for normal seconds) then press “send.” operation. Philips Lighting North America...
Point remote to any of the luminaires Test feature is activated; users and press “test.” can now walk in the space to estimate the occupancy coverage area. To stop the test feature, press the “test” button again. Philips Lighting North America...
27% will be delivered. SpaceWise luminaires can also be ordered with a Philips emergency driver option. If this configuration is purchased then luminaires don’t have to be configured as “path of egress”...
Page 27
Red LED on remote will start blinking. While the LED is still blinking red, enter Red LED on remote will stop the numbers: blinking. “11”: Enable path of egress feature “10”: Disable path of egress feature Philips Lighting North America...
Page 28
Point to any of the luminaires in the Red LED on remote will start group and press “lock.” blinking. The luminaire will FLASH twice. Wait for LED to stop blinking (apx. 10 Group is ready for normal seconds) then press “send.” operation. Philips Lighting North America...
Once LED stops blinking, with remote Luminaire will turn OFF and then still pointing to the luminaire in the turn back ON to indicate reset. group, press “send.” Repeat step “b” for all the luminaires that need to be reset. Philips Lighting North America...
D. Do my luminaires forget their settings after power is lost or interrupted? No, all settings are retained as long as the luminaires have not been factory reset or there has been a hardware failure. Philips Lighting North America...