IMPORTANT SAFEGUARDS 1. Read Instructions - All the safety and operating instructions should be read before the unit is operated. 2. Retain Instructions - The safety and operating instructions should be retained for future reference. 3. Heed Warnings - All warnings on the unit and in the operating instructions should be adhered to.
SAFETY PRECAUTIONS Caution: To reduce the risk of electrical shock, do not open covers. No user serviceable parts inside. Refer servicing to qualified service personnel This label may appear on the bottom of the unit due to space limitations. The lightning flash with an arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage"...
Page 4
SICHERHEITSVORKEHRUNGEN VORSICHT: Um einen elektrischen schlag zu vermeiden, abdeckung nicht entfernen. Wartungen aller art qualifiziertem personal überlassen. Aus Platzgründen kann diese Warnung auf der Unterseite des Gerätes angebracht sein. Das Blitzsymbol im gleichseitigen Dreieck soll den Benutzer auf nicht isolierte “Hochspannung” im Gehäuse aufmerksam machen, die eventuell stark genug ist, um einen elektrischen Schlag zu verursachen.
LTC 2277 Series and LTC 2278 Series models. If an item appears to have been damaged in shipment, replace it properly in its carton and notify the shipper. If any items are missing, notify your Philips Communication & Security Systems Inc. Sales Representative or Customer Service.
Cover Removal WARNING: Removal of the cover should only be performed by qualified service personnel-- not user serviceable.The unit should always be unplugged, before removing the cover and remain unplugged while the cover is removed. Démontage du Couvercle Le démontage du couvercle et le réglage des commandes internes doivent être effectués par du personnel qualifié- pas de service par l'utilisateur.
Alarm Inputs and Output (Accessory Output) 4.6.1 LTC 2277 Series and LTC 2278 Series The 609 mm (24 in) cable, with 15 pin connectors provided ® with the VidQuad units, are for use with the mating alarm input, output and accessory connectors. These cables can be cut to desired length, and the end insulation stripped off for connecting external devices.
Monitor Operation 5.2.1 Monitor Display Outputs The front panel buttons can be used to operate either on the MON-A monitor display, or on the MON-B monitor display. The MON-A monitor displays a digitized image and so Zoom and Freeze operations can be performed on the MON-A monitor.
Page 9
Zoom During VCR Playback To zoom a quadrant in the recorded VCR display on the MON-A monitor, select that quadrant as the active quadrant by using the arrow buttons. An asterisk (*) will indicate the active quadrant. Press ZOOM to zoom that quadrant to full screen display.
5.2.10 MON-B Monitor Display The secondary monitor output, designated as the MON-B monitor, is used for selecting analog full-screen displays of any one of the eight camera inputs, or to display a sequenced list of full-screen displays. The MON-B monitor output is analog and so digital functions such as quad compression, zoom and freeze are not available on the MON-B monitor.
5.3.6 Video Loss Action Upon video loss to any input, the corresponding camera image on the MON-A display is automatically frozen, and a video loss warning message, "VDL" is displayed on the corresponding quadrant as well as on the associated MON-B monitor display.
Page 12
Front Panel - LTC 2275 Series Typical Application - LTC 2275 Series...
Page 13
Front Panel - LTC 2277 Series and LTC 2278 Series and Typical Application - LTC 2278 Series NO: Normally Open - Relay to ground. NC: Normally Closed - Relay to ground. S929A45AE Back Panel - LTC 2277 Series Alarm/Accessory Connector - Pin-Out Function Function Ground...
Need help?
Do you have a question about the VidQuad LTC 2275/50 and is the answer not in the manual?
Questions and answers