Wired Controller Installation and Operation Manual QACT17A Table of Contents Parts and Functions Interface Display .................1 Icons ....................2 Dip Switch ...................4 Operation Mode Key ..................6 Fan Key ..................6 Temperature Adjustment Keys ..........7 Special Function Special Function Selection ............8 Installer Settings Adjust ECO Parameters ............10...
Parts and Functions Icons Room temperature display ( dip switch SW1-2 on). Set temperature display Filter HRV (Heat Reclaim Ventilation), if HRV function is set, it will display this icon Error icon displays detected fault ECO mode on Central/lock when connected to a central controller UP/DOWN louver swing LEFT/RIGHT louver swing...
Page 4
Parts And Functions MAIN / SUB Main / Subordinate wired controller Quiet Fan Speed (some models) Low Fan Speed Medium Fan Speed High Fan Speed Turbo Fan Speed (some models) Auto Fan speed is indicated by the display automatically stepping from low to high repeatedly. Auto Mode Cooling Mode Heating Mode...
Dip Switch Dip Switch SW1 Default Sw1-1 Subordinate wired Main wired controller controller Room temperature Sw1-2 Room temperature display on Sw1-3 Room temperature Room temperature collected from indoor unit collected from controller Auto restart after power Sw1-4 power loss loss Old protocol (models Sw1-5 New protocol...
Page 6
Dip Switch Dip Switch SW2 Default Sw2-1 Mode Lock Normal Sw2-2 Tone on still sound when command is sent by wireless remote. Sw2-3 Reserved Reserved Sw2-4 Reserved Reserved Initialization the Room Temperature display and the Set Temperature display until communication is established with the indoor unit. Audible Alert Press to power ON or power OFF the control.
Mode Key / Fan Key Mode key: • Each press of the MODE button will change the operating mode • Each mode has its initial default fan speed. Mode Fan speed Temperature Auto Auto 76°F Cool High 76°F Initial Heat Auto 76°F State...
Temperature Temperature Adjustment Keys: • Press the TEMP+ or TEMP- keys to change the temperature by 1°F increments. • The temperature set point range for Auto, Cooling, Heating then temperature range will change per the ECO setting parameters). • The temperature is set independently under Auto, Cooling, Heating and Dehumidify modes.
Function Selection Special Function Selection: With the control powered on, press and hold the TEMP+ for 5 seconds to enter the special function menu. All the special function icons will display. Use the TEMP+ and TEMP- buttons to move between icons. Use FAN button to select function.
Installer Settings Adjust ECO Parameters: • Cooling: Power on the unit. Adjust set temperature to 86°F. Press and hold FAN and TEMP+ for 5 seconds. The minimum allowable set temperature will be displayed in the top right corner. Use TEMP+/- to change the parameter, then press FAN save.
Lock Settings / Fahrenheit Setting Central/Lock Function: Function is active only when system has a central control, such as the YCZ-A004. This setting is activated only by the central Control. Central Control Central Lock No functions available. Fahrenheit Setting and Display: •...
Temperature Compensation Set Temperature Compensation: display will then show 0 (default) or current compensation setting. Use TEMP+/- buttons to adjust the compensation. Compensation can be set in 1° increments +/- 8°F (0.5°C increments up to +/-4°C). • Temperature compensation changes the ambient temperature reading.
Error Checks How to check error: will display. error history will appear in the top right corner. The current error will appear in the middle of the screen. If there is no error, “--” will display.
Mode Restriction Mode Restriction Function: • When SW2-1 is on, the system mode lock is on. This will lock the mode to Heat, Cool, Dry or Fan. No button press can change mode. All other control functions are available such as •...
Parameter Inquiry: Display Description Value Indoor sensor - Ambient (Tai) Temperature °F (°C) Indoor sensor - Vapor (Tc1) Temperature °F (°C) Indoor sensor - Liquid (Tc2 Temperature °F (°C) Indoor EEV position Half of actual position Indoor unit address Shown in hexadecimal Indoor unit central address Shown in hexadecimal Mode Combination Setting...
Page 17
One Controller for up to 16 indoor Indoor N Indoor 15 Indoor 16 Indoor 2 Indoor 1 (main unit) Wired controller Wired controller Wired controller Wired controller Wired controller A B C A B C A B C A B C A B C Control wiring of wired A B C...
Page 18
Wiring Connections 3. Non-MRV Wall Mount (AW...) High Wall ..Unit 1 Unit 0 Unit 15 WK-B (main unit) A B C A B C A B C W ired controller Dipswitch position Dipswitch position Unit # Unit # connect with WK-B is considered as main unit 0.
Page 19
Wired Controller Wiring Instruction Communication Wiring Wire Size Communication wiring length (m/ft) 0.3mm x3-core shielded wire < 100m/328ft (22AWG,3wire) 0.5mm x3-core shielded wire (20AWG,3wire) 0.75mm x3-core shielded wire (18AWG,3wire) 1.25mm x3-core shielded wire (16AWG,3wire) x3-core shielded wire (14AWG,3wire) *Ground only one end of the shielded cable Wiring Diagrams yellow white...
Page 20
Wired Controller Wiring Instruction Installation Diagrams 1. To take the front panel and back panel apart, slide the front panel up and press down on the back panel. 2. Secure the back panel to the wall using screws. 3. Connect the control wires. 4.
Page 21
CAN ICES3(A)/NMB3(A) MANUFACTURER GE Appliances, a Haier Company Appliance Park Louisville, KY 40225 WEBSITE www.Haierductless.com...
Page 22
Table des matières Composants et fonctions Fonctionnement Fonctions spéciales Réglages de l’installateur...
Page 39
High Wall ..Unit 0 Unit 1 Unit 15 WK-B (main unit) A B C A B C A B C W ired controller Indoor 1 Wired controller A B C Polar wire Polar wire Polar wire A B C A B C Wired controller Wired controller...
Page 43
Manual de Instalación y Funcionamiento QACT17A Índice Piezas y Funciones Pantalla de Interfaz ................1 Íconos ....................2 Interruptor DIP ................4 Funcionamiento Tecla de Modo ..................6 Tecla del Ventilador .................6 Teclas de Ajuste de Temperatura ...........7 Función Especial Selección de Función Especial ............8 Parámetros de Ajuste ECO ............10...
Piezas y Funciones Íconos DIP SW1-2 encendido). Filtro falla ECO mode on conectado a un controlador central. Bloqueo para niños...
Page 46
Piezas y Funciones Velocidad de Ventilación Velocidad de Ventilación Baja Velocidad de Ventilación Media Velocidad de Ventilación Alta Velocidad de Ventilación Modo Automático Modo de Calefacción Modo de Ventilación...
Interruptor DIP ENCENDIDO APAGADO Omisión Sw1-1 APAGADO principal Pantalla de temperatura Sw1-2 Pantalla de temperatura APAGADO Sw1-3 recolectada de la unidad recolectada del interior controlador Sw1-4 El sistema permanece APAGADO APAGADO elos desarrollados antes Sw1-6 APAGADO encendida Sw1-7 APAGADO Sw1-8 APAGADO...
Page 48
Dip Switch ENCENDIDO APAGADO Omisión Sw2-1 Bloqueo del Modo Normal APAGADO Sw2-2 APAGADO Sw2-3 APAGADO Sw2-4 APAGADO Inicio unidad interna. Alerta Sonora...
Tecla de Modo / Tecla del Ventilador Modo Temperatura Automático Automático 76°F Estado Alta 76°F Inicial Calor Automático 76°F Ventilador Bajo Sin pantalla de temperatura Automático 76°F Velocidad de Ventilación Velocidad de Ventilación Baja Velocidad de Ventilación Media Velocidad de Ventilación Alta...
Controles de Errores esquina superior derecha. El error actual aparecerá en el medio...
Page 58
Monitor Descripción Valor Posición interior EEV Dirección de la unidad interior Dirección central de la unidad interior los modos de funcionamiento omisión. Un control en una parte interna Indoor 1 WK-B Wired controller A B C Polar wire A B C A B C A B C A B C...
Page 59
B: Un controlador para hasta 16 partes internas Indoor N Indoor 16 Indoor 2 Indoor 1 Wired controller Wired controller Wired controller Wired controller Wired controller A B C A B C A B C A B C A B C A B C Wired controller Indoor N...
Page 60
High Wall ..Unit 1 Unit 0 Unit 15 WK-B (main unit) A B C A B C A B C W ired controller Dipswitch position Dipswitch position para conectar con el WK-B es considerada la unidad maestra 0. Unit # Unit # conectar al CN1 de la unidad maestra WK-B...
Page 61
0.3mm < 100m/328ft el centro yellow white...
Page 62
Para separar el panel frontal el panel trasero. usando tornillos. Adhiera el control al panel...