Page 4
Copyright This document and parts thereof must not be reproduced or copied without written permission from ABB, and the contents thereof must not be imparted to a third party, nor used for any unauthorized purpose. The software or hardware described in this document is furnished under a license and may be used, copied, or disclosed only in accordance with the terms of such license.
Page 5
In case any errors are detected, the reader is kindly requested to notify the manufacturer. Other than under explicit contractual commitments, in no event shall ABB be responsible or liable for any loss or damage resulting from the use of this manual or the application of the equipment.
Page 6
(EMC Directive 2004/108/EC) and concerning electrical equipment for use within specified voltage limits (Low-voltage directive 2006/95/EC). This conformity is the result of tests conducted by ABB in accordance with the product standards EN 50263 and EN 60255-26 for the EMC directive, and with the product standards EN 60255-1 and EN 60255-27 for the low voltage directive.
Table of contents Table of contents Section 1 Introduction...............7 This manual..................7 Intended audience................7 Product documentation...............7 Product documentation set............7 Document revision history.............8 Related documentation..............8 Symbols and conventions..............9 Symbols..................9 Document conventions..............9 Functions, codes and symbols............10 Section 2 DNP3 data mappings.............13 Overview...................13 Supported functions................13 Binary inputs..................15 System functions.................15 CTRL.LLN0 Local/remote state (also present in DNP IIN-...
Page 8
Table of contents LD0.LEDPTRC1 Global protection signals......20 LD0.TRPPTRC1 Global conditioning (1)........20 LD0.TRPPTRC2 Global conditioning (2)........21 LD0.FRPFRQ1 Frequency protection (1).......21 LD0.FRPFRQ2 Frequency protection (2).......21 LD0.FRPFRQ3 Frequency protection (3).......21 LD0.FRPFRQ4 Frequency protection (4).......22 LD0.FRPFRQ5 Frequency protection (5).......22 LD0.FRPFRQ6 Frequency protection (6).......22 LD0.LSHDPFRQ1 Load-shedding - instance 1......23 LD0.LSHDPFRQ2 Load-shedding - instance 2......23 LD0.LSHDPFRQ3 Load-shedding - instance 3......23 LD0.LSHDPFRQ4 Load-shedding - instance 4......24...
Page 9
Table of contents LD0.SECRSYN1 Synchrocheck ..........28 Generic functions.................29 LD0.MAPGAPC1 Multipurpose analog protection function (1)................29 LD0.MAPGAPC2 Multipurpose analog protection function (2)................29 LD0.MAPGAPC3 Multipurpose analog protection function (3)................29 LD0.MAPGAPC4 Multipurpose analog protection function (4)................29 LD0.MAPGAPC5 Multipurpose analog protection function (5)................29 LD0.MAPGAPC6 Multipurpose analog protection function (6)................30 LD0.MVGAPC1 Multipurpose binary inputs (1)......30 LD0.MVGAPC2 Multipurpose binary inputs (2)......30...
Page 10
Table of contents Generic functions.................36 LD0.SPCGGIO1 Multipurpose binary outputs (1)....36 LD0.SPCGGIO2 Multipurpose binary outputs (2)....37 LD0.SRGAPC1 Multipurpose binary outputs - flip-flop resets (1)................38 LD0.SRGAPC2 Multipurpose binary outputs - flip-flop resets (2)................38 Analog inputs..................38 System functions.................39 CTRL.LLN0 Local remote station off........39 LD0.LPHD1 System values............39 LD0.DNPGGIO1 Active parameter setting group....39 LD0.LEDGGIO1 LHMI LED indications (3 states)....40...
Page 11
Table of contents Protection functions..............45 LD0.T2PTTR1 Temperature protection values (2)....45 Protection-related functions............45 DR.RDRE1 Disturbance recorder values.......45 LD0.SECRSYN1 Synchrocheck line and bus state....45 Generic functions.................46 LD0.XRGGIO130 RTD inputs..........46 Section 3 DNP3 protocol implementation........47 DNP3 device profile................47 DNP3 implementation table..............49 Section 4 Glossary.................53 REU615 Point List Manual...
Section 1 1MRS757056 C Introduction Section 1 Introduction This manual The point list manual describes the outlook and properties of the data points specific to the IED. The manual should be used in conjunction with the corresponding communication protocol manual. Intended audience This manual addresses the communication system engineer or system integrator responsible for pre-engineering and engineering for communication setup in a...
Content updated to correspond to the product version C/2013-02-21 4.0 FP1 Content updated to correspond to the product series version Download the latest documents from the ABB Website http://www.abb.com/substationautomation. 1.3.3 Related documentation Name of the document Document ID DNP3 Communication Protocol Manual...
Section 1 1MRS757056 C Introduction Symbols and conventions 1.4.1 Symbols The caution icon indicates important information or warning related to the concept discussed in the text. It might indicate the presence of a hazard which could result in corruption of software or damage to equipment or property.
Section 2 1MRS757056 C DNP3 data mappings Section 2 DNP3 data mappings Overview This document describes the DNP3 data points and structures available in the IED. The data points are unmapped as a default on the DNP3 level. The point lists describe a superset of all DNP3 data available through the standard configuration/s including the optional functionalities.
Section 2 1MRS757056 C DNP3 data mappings 2.3.4 Automatic control functions 2.3.4.1 LD0.OLATCC1 On-load tap changer controller Table 15: LD0.OLATCC1 On-load tap changer controller IEC 61850 name SA name Description Values LD0.OLATCC1 .ParOp.stVal PARALLEL Parallel or single op. 1=Parallel .Auto.stVal AUTO Auto or manual op.
Section 2 1MRS757056 C DNP3 data mappings 2.3.5.3 LD0.VMMXU1 Three-phase voltage limit supervision Table 18: LD0.VMMXU1 Three-phase voltage limit supervision IEC 61850 name SA name Description Values LD0.VMMXU1 .HiAlm.stVal HIGH_ALARM High alarm 1=Alarm .HiWrn.stVal HIGH_WARN High warning 1=Warning .LoAlm.stVal LOW_ALARM Low alarm 1=Alarm .LoWrn.stVal...
Section 2 1MRS757056 C DNP3 data mappings 2.3.6.3 LD0.TRPPTRC2 Global conditioning (2) Table 22: LD0.TRPPTRC2 Global conditioning (2) IEC 61850 name SA name Description Values .Op.general Operate input signal 1=Operate .Tr.general Trip output signal 1=Trip 2.3.6.4 LD0.FRPFRQ1 Frequency protection (1) Table 23: LD0.FRPFRQ1 Frequency protection (1) IEC 61850 name...
Section 2 1MRS757056 C DNP3 data mappings IEC 61850 name SA name Description Values .Op.general OPR_OFRQ -Operate 1=Operate LD0.FRPTUF3 Underfrequency .Op.general OPR_UFRQ -Operate 1=Operate LD0.FRPFRC3 Frequency gradient .Op.general OPR_FRG -Operate 1=Operate 2.3.6.7 LD0.FRPFRQ4 Frequency protection (4) Table 26: LD0.FRPFRQ4 Frequency protection (4) IEC 61850 name SA name Description...
Section 2 1MRS757056 C DNP3 data mappings 2.3.8 Generic functions 2.3.8.1 LD0.MAPGAPC1 Multipurpose analog protection function (1) Table 55: LD0.MAPGAPC1 Multipurpose analog protection function (1) IEC 61850 name SA name Description Values LD0.MAPGAPC1 .Op.general OPERATE Stage operate 1 = Operate .Str.general START Stage start...
Section 2 1MRS757056 C DNP3 data mappings IEC 61850 name SA name Description Type .ActSG4.ctlVal Setting group 4 .ActSG5.ctlVal Setting group 5 .ActSG6.ctlVal Setting group 6 2.4.2 Switchgear functions 2.4.2.1 CTRL.CBCSWI1 Circuit breaker control Table 72: CTRL.CBCSWI1 Circuit breaker control IEC 61850 name SA name Description...
Section 2 1MRS757056 C DNP3 data mappings 2.4.3 Metering and measurand functions 2.4.3.1 LD0.PEMMXU1 Reset accumulated energy values Table 76: LD0.PEMMXU1 Reset accumulated energy values IEC 61850 name SA name Description Type LD0.PEMMXU1 .SupDmdRs.Oper.ctlVal RSTACM Reset accum. energy 2.4.4 Protection functions 2.4.4.1 LD0.LSHDPFRQ1 Loadshedding controls (1) Table 77:...
Section 2 1MRS757056 C DNP3 data mappings IEC 61850 name SA name Description Type .SPCS04.ctlVal Output 4 control On/Off .SPCS05.ctlVal Output 5 control On/Off .SPCS06.ctlVal Output 6 control On/Off .SPCS07.ctlVal Output 7 control On/Off .SPCS08.ctlVal Output 8 control On/Off .SPCS09.ctlVal Output 9 control On/Off .SPCS10.ctlVal...
Section 2 1MRS757056 C DNP3 data mappings Column name Description Values The value range of the original IEC 61850 data. Scaling is needed to convert floating point data into DNP3 integer values. Scaling type selected as default. Default “R” means ratio scaling. See the DNP communication protocol manual for details.
Section 2 1MRS757056 C DNP3 data mappings 2.5.1.4 LD0.LEDGGIO1 LHMI LED indications (3 states) Table 91: LD0.LEDGGIO1 LHMI LED indications (3 states) IEC 61850 name SA name Description Values Arg 1,2,3,4 LD0.LEDGGIO1 0/1/3=Off/Ok/ .ISCSO1.stVal LED 1 state Alarm 0,3,0,3 0/1/3=Off/Ok/ .ISCSO2.stVal LED 2 state Alarm...
Section 2 1MRS757056 C DNP3 data mappings 2.5.5.8 LD0.FMMXU1 Frequency measurement Table 110: LD0.FMMXU1 Frequency measurement IEC 61850 name SA name Description Values Arg 1,2,3,4 LD0.FMMXU1 .Hz.mag Frequency value 35…75 [Hz] 35,75,3500,7500 2.5.6 Protection functions 2.5.6.1 LD0.T2PTTR1 Temperature protection values (2) Table 111: LD0.T2PTTR1 Temperature protection values (2) IEC 61850 name...
Implementation table and the point list tables, provides a complete configuration/interoperability guide for communicating with a device. Table 115: Device profile document DNP3 device profile document Vendor name: ABB Oy Device name: REU615 Highest DNP level supported: Device function: For requests: Level 2+ ○...
Page 54
Section 3 1MRS757056 C DNP3 protocol implementation DNP3 device profile document ○ Sometimes ● Configurable as: "Only when reporting event data", or "When reporting event data or multi-fragment messages" Timeouts while waiting for: Data link ○ None ○ Fixed at ____ ○...
Section 3 1MRS757056 C DNP3 protocol implementation DNP3 device profile document ○ Configurable ○ When device restarts ○ Only certain objects ○ When status flags change ○ Sometimes (attach explanation) ○ ENABLE/DISABLE UNSOLICITED No other options are permitted. function codes supported Default counter object/variation: Counters roll over at: ●...
Page 56
Section 3 1MRS757056 C DNP3 protocol implementation Table 116: Implementation table OBJECT REQUEST (Library will parse) RESPONSE (Library will respond with) Object Variation Function codes Qualifier codes number number Description Function codes (dec) Qualifier codes (hex) (dec) (hex) Binary 1 (read) 00, 01 (start-stop) input –...
Page 57
Section 3 1MRS757056 C DNP3 protocol implementation OBJECT REQUEST (Library will parse) RESPONSE (Library will respond with) 16-bit 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop) 2 (default) analog 06 (no range, or all) 17, 28 (index) input 07, 08 (limited qty) 17, 28 (index) 32-bit...
Page 58
Section 3 1MRS757056 C DNP3 protocol implementation OBJECT REQUEST (Library will parse) RESPONSE (Library will respond with) Time delay 129 (response) 07 (limited qty) fine (qty = 1) Not defined Class 0 1 (read) 06 (no range, or all) data Class 1 1 (read) 06 (no range, or all)
Section 4 1MRS757056 C Glossary Section 4 Glossary Application function block library CROB Control relay output block Common time of occurrence. The time and date CTO object is an information object that represents the absolute time of day. DNP3 A distributed network protocol originally developed by Westronic.
Page 64
Contact us ABB Oy Medium Voltage Products, Distribution Automation P.O. Box 699 FI-65101 VAASA, Finland Phone +358 10 22 11 +358 10 22 41094 ABB Limited Distribution Automation Maneja Vadodara 390013, India Phone +91 265 2604032 +91 265 2638922 www.abb.com/substationautomation...
Need help?
Do you have a question about the Relion REU 615 and is the answer not in the manual?
Questions and answers