Page 1
All manuals and user guides at all-guides.com CASSETTE TYPE AIR CONDITIONER Operation & Installation Manual...
Page 2
All manuals and user guides at all-guides.com Contents...
Page 3
All manuals and user guides at all-guides.com Cautions Disposal of the old air conditioner Safety Instructions and Warnings Disposal of the packaging of your new air conditioner...
Page 4
All manuals and user guides at all-guides.com Cautions Specifications The machine is adaptive in following situation...
Page 5
All manuals and user guides at all-guides.com Cautions Safety cautions Carefully read the following information in order to operate the airconditioner correctly. WARNING! CAUTION! INSTRUCTIONS: The Safety Cautions should be at hand so that they can be checked at any time when needed. WARNING! Don't blow the human body with the cooling Please let the dealer be responsible for installing...
Page 6
All manuals and user guides at all-guides.com Cautions CAUTIONS! Don't operate the air-con- Conditioner should not be used for any other ditioner with damp hands. purpose other than airconditioning. Only use correctly-typed fuse. Don't place any burning unit Don't dismantle the outlet of the outdoor unit. in the air flow of air-conditioner, which may cause incomplete combustion.
All manuals and user guides at all-guides.com Cautions Installation WARNING ! Please call dealer to install the air-conditioner. CAUTION ! Air-conditioner can't be installed in the envi- Connect earthing wire. ronment with inflammable gases because the inflammable gases near to air-conditioner may cause fire hazard.
All manuals and user guides at all-guides.com Maintenance...
Page 10
All manuals and user guides at all-guides.com Maintenance [Clean air filter] NOTE 1. Open inlet grill 5. Install air filter 2. Open two othooks 3. Dismantle air filter 6. Close inlet grill 7. Press the filter signal return key on the controller.
Page 11
All manuals and user guides at all-guides.com Maintenance 2. Take off air-filter 3. Take of inlet grill [Dismantle and install swing plate ] 1. Fix the swing plate at the bottom. 2. Dismantle the swing plate. CAUTION! 4. Clean CAUTION! NOTE Dismantle and install swing plate...
Page 12
All manuals and user guides at all-guides.com Maintenance Clean the air filter Instructions : 1. Open air inlet grille 2.Dismantle the air filter 3. Clean Use cleaner or water to clean to remove dust.
Page 13
All manuals and user guides at all-guides.com Maintenance 4. Install air filter 5. Close air inlet grille Clean the air inlet grille 1. Open air inlet grille 2. Remove air filter 3. Remove the air inlet grille 4. Clean 5. Install air inlet grille 6.
Page 14
All manuals and user guides at all-guides.com Maintenance NOTE The inner part of indoor unit must be cleaned. Consult dealer, because clean must be done by technician. In cooling operation, discharging system discharge water in room.
All manuals and user guides at all-guides.com Installation Procedure CAUTIONS: To ensure proper installation, read "Cautions" carefully before working. After installation, start the unit correctly and show customers how to operate and maintain the unit. Meanings of Warning and Cautions: Warning! Serious injury or even death might happen, if it is not observed.
Page 22
All manuals and user guides at all-guides.com Installation Procedure 1. BEFORE INSTALLATION <Don't discard any accessories until comp> 2. SELECTION OF INSTALLATION PLACE (For series 122,182 ) (For series 242, 282, 362,422,522, 482, 602 ) 3. PREPARATION FOR THE INSTALLATION (For series 122,182 ) (For series 242, 282 )
Page 23
All manuals and user guides at all-guides.com Installation Procedure (For series 482, 522,602 and AB362ACERA) 860-890 (ceiling hole) (For AB362ACEAA AB422AEEAA ) (Hanging position) Wall or barrier Barrier Ground <Installation example>...
Page 24
All manuals and user guides at all-guides.com Installation Procedure 4. INSTALLATION OF INDOOR UNIT In the case of new ceiling < After installation on the ceiling > In the case of ceiling already exists...
Page 25
All manuals and user guides at all-guides.com Installation Procedure 5. REFRIGERANT PIPING As for outdoor piping, please refer to installation Manual of outdoor unit. Table 1 6. INSTALLATION OF WATER DRAINAGE PIPE Cautions for the drain water lifting pipe...
Page 26
All manuals and user guides at all-guides.com Installation Procedure...
Page 27
All manuals and user guides at all-guides.com Installation Procedure After wiring When wiring is not complete...
Page 28
All manuals and user guides at all-guides.com Installation Procedure 7. WIRING << WARNING 8. WIRING EXAMPLE Note: 9. INSTALLATION OF ORNAMENT PANEL Cautions for the installation Accessory Pad 1. Prepare ornament panel Handling of ornament panel Remove air inlet grill from ornament panel * Remove cover plate at corner...
Page 29
All manuals and user guides at all-guides.com Installation Procedure 2. Mounting on high ceiling If connecting is not made, error code (A7) appears on remote controller. So, make proper connecting. 3. Install ornament panel on indoor unit. For indoor unit installation, please refer to Installation Manual.
Page 30
All manuals and user guides at all-guides.com Installation Procedure 4. Installation of inlet grill and cover plate When installing inlet grill, take care not to twist wiring of swing flap motor. Pay special care to the following and check after installation Unproper installation may cause Item to the checked Check...
Page 31
All manuals and user guides at all-guides.com...