1. Important • Please use approved power cord provided 1. Important by Philips all the time. If your power cord is missing, please contact with your local This electronic user’s guide is intended for service center. (Please refer to Customer anyone who uses the Philips monitor.
1. Important • Temperature: 0-40°C 32-95°F 1.2 Notational Descriptions • Humidity: 20-80% RH The following subsections describe notational Important information for Burn-in/Ghost conventions used in this document. image. Notes, Cautions and Warnings • Always activate a moving screen saver Throughout this guide, blocks of text may be program when you leave your monitor accompanied by an icon and printed in bold or unattended.
WEEE performance of the organization's product, service and activities. From the planning, design and production stages, Philips emphasizes the important of making products that can easily be recycled. At Philips, end-of-life management primarily entails participation innational take-back initiatives and recycling programs whenever possible,...
Monitor drivers hands and firmly insert the base stand into SmartControl software the base column. Philips and the Philips’ Shield Emblem are registered trademarks of Koninklijke Philips N.V. and are used under license from Koninklijke Philips N.V. * DVI * Depends on the country...
AC power input VGA input DVI-D input (available for selected models) Kensington anti-theft lock Connect to PC Model 200V4Q: 1. Connect the power cord to the back of the monitor firmly. 2. Turn off your computer and unplug its power cable.
Page 8
Sub menu What is On-Screen Display (OSD)? On-Screen Display (OSD) is a feature in all Input Philips LCD monitors. It allows an end user to adjust screen performance or select functions Wide Screen, 4:3 Picture Format of the monitors directly through an on-screen...
2. Setting up the monitor Resolution notification 2.3 Remove Base Stand This monitor is designed for optimal Remove the Base Stand performance at its native resolution, 1920×1080@60Hz. When the monitor is Before you start disassembling the monitor powered on at a different resolution, an alert is base, please follow the instructions below to displayed on screen: Use 1920×1080@60Hz for avoid any possible damage or injury.
Page 10
2. Setting up the monitor Note This monitor accepts a 100mm x 100mm VESA- Compliant mounting interface. 100mm 100mm Caution For use only with UL Listed Wall Mount Bracket with minimum weight/load 3.5Kg...
• You can adjust more options without 3.2 Philips SmartControl Lite wizard by Standard pane. The new SmartControl Lite software by Philips allows you to control your monitor via an easy to use on-screen graphic interface. Complicated adjustments are a thing of the past as this user...
Page 12
3. Image Optimization Start with Standard pane: Adjust menu: • Adjust Menu allow you to adjust Brightness, Contrast, Focus, Position and Resolution. • You can follow the instruction and do the adjustment. • Cancel prompts user if you want to cancel installation.
Page 13
3. Image Optimization Color menu: • Color Menu allow you to adjust RGB, Black Level, White Point, and Color Calibration. • You can follow the instruction and do the adjustment. • Refer to below table for sub-menu item base on your input. • Example for Color Calibration:...
Page 14
3. Image Optimization 1. "Show Me" starts color calibration tutorial. 2. Start - starts the 6-step color calibration sequence. 3. Quick View loads the before/after images. 4. To return to Color home pane, click the Cancel button. 5. Enable color calibration - by default is on. If unchecked, does not allow for color calibration to happen, dimes out start and quick view buttons.
Page 15
3. Image Optimization menu. On a non-supported display capable of Help>User Manual - Will only be active when DDC/CI, only the Help and Options tabs are selecting User Manual from the drop-down available. All other SmartControl Lite tabs are Help menu. On a non-supported display not available.
Page 16
3. Image Optimization Context Sensitive menu • Check for Update - takes the user to PDI Landing and checks the user’s version The Context Sensitive menu is Enabled by against the most current available. default. If Enable Context Menu has been checked in the Options>Preferences pane, then • About - Displays detailed reference the menu will be visible.
4. Technical Specifications 4. Technical Specifications Picture/Display Monitor Panel Type MVA LCD Backlight Panel Size 19.53" W (49.6cm) Aspect Ratio 16:9 Pixel Pitch 0.23X0.22mm Brightness 250 cd/m² SmartContrast 10,000,000:1 Contrast Ratio (typ.) 3000:1 Response Time (typ.) 20ms(200V4QSB) SmartResponse 8ms(GtG)(200V4QSBR) Optimum Resolution 1920×1080@60Hz Viewing Angle 178°...
Page 18
Finish Glossy/Texture Note 1. EPEAT Gold or Silver is valid only where Philips registers the product. Please visit www.epeat.net for registration status in your country. 2. This data is subject to change without notice. Go to www.philips.com/support to download the...
5. Power Management 5. Power Management If you have VESA DPM compliance display card or software installed in your PC, the monitor can automatically reduce its power consumption when not in use. If an input from a keyboard, mouse or other input device is detected, the monitor will 'wake up' automatically.
6. Regulatory Infomation • Packaging 6. Regulatory Information Limits on hazardous substances in product packaging. Packaging prepared for recycling (The regulations may differ depending on your • Ergonomic, User-centered design country) Visual ergonomics in products with a Congratulations! display. Adjustability for user comfort (displays, headsets) Acoustic performance This product is TCO Certified - for Sustainable –...
Page 22
Information Technology on hazardous substances in electrical and Equipment). electronic equipment have been adhered to in order to make Philips monitors safe to use • EN55024:2010 (Immunity requirement of throughout its life cycle. Information Technology Equipment). • EN61000-3-2:2006 +A1:2009+A2:2009 EPEAT (Limits for Harmonic Current Emission).
Page 23
6. Regulatory Infomation Energy Star Declaration Changes or modifications not expressly approved by the party responsible for (www.energystar.gov) compliance could void the user's authority ® As an ENERGY STAR Partner, we to operate the equipment. have determined that this product Use only RF shielded cable that was supplied ®...
Page 24
6. Regulatory Infomation nuisibles aux communications radio. EN 55022 Compliance (Czech Republic Only) Cependant, rien ne peut garantir l'absence d'interférences dans le cadre d'une installation particulière. Si cet appareil est la cause d'interférences nuisibles pour la réception des signaux de radio ou de télévision, ce qui peut être décelé...
Page 25
6. Regulatory Infomation North Europe (Nordic Countries) Information Ergonomie Hinweis (nur Deutschland) Der von uns gelieferte Farbmonitor entspricht Placering/Ventilation den in der "Verordnung über den Schutz vor VARNING: Schäden durch Röntgenstrahlen" festgelegten FÖRSÄKRA DIG OM ATT HUVUDBRYTARE Vorschriften. OCH UTTAG ÄR LÄTÅTKOMLIGA, NÄR DU STÄLLER DIN UTRUSTNING PÅPLATS.
Page 26
How to connect a plug waste equipment for recycling in India please The wires in the mains lead are coloured in visit the below web link. accordance with the following code: http://www.india.philips.com/about/sustainability/ BLUE -“NEUTRAL”(“N”) recycling/index.page BROWN -“LIVE”(“L”) GREEN&YELLOW -“EARTH”(“E”) Information for U.K. only 1.
Page 27
6. Regulatory Infomation to the terminal which is marked with the 下不会发生外泄或突变 , 电子信息产品用户 letter "L" or coloured RED. 使用该电子信息产品不会对环境造成严重 污染或对其人身、 财产造成严重损害的期 Before replacing the plug cover, make certain 限. that the cord grip is clamped over the sheath of the lead - not simply over the three wires.
No manufacturer can guarantee the types of bright dot defects. that all panels will be free from pixel defects, but Philips guarantees that any monitor with an unacceptable number of defects will be repaired or replaced under warranty. This notice explains the different types of pixel defects and defines acceptable defect levels for each type.
Page 29
In order to qualify for repair or replacement due to pixel defects during the warranty period, a TFT Monitor panel in a Philips flat panel monitor must have pixel or sub pixel defects exceeding the tolerances listed in the following tables.
7.2 Customer Care & Warranty For warranty coverage information and additional support requirement valid for your region, please visit www.philips.com/support website for details. You may also contact your local Philips Customer Care Center number listed below. Contact Information for WESTERN EUROPE region:...
Philips customer service representative. • Disconnect the monitor from mains power source immediately for safety Common Problems • Contact with Philips customer service No Picture (Power LED not lit) representative immediately. • Make sure the power cord is plugged into...
• Eliminate the vertical bars using the Phase/ For further assistance, refer to the Consumer Clock of Setup in OSD Main Controls. It is Information Centers list and contact Philips valid only in VGA mode. customer service representative. Image appears blurred, indistinct or too dark 8.2 General FAQs...
Page 35
PC, workstation or Mac? blunt objects. When handling the monitor, Ans.: Yes. All Philips LCD monitors are fully make sure that there is no pressure or compatible with standard PCs, Macs force applied to the panel surface side.
Page 36
8. Troubleshooting & FAQs imaging" will disappear gradually over a period of time after the power has been switched off. Always activate a moving screen saver program when you leave your monitor unattended. Always activate a periodic screen refresh application if your LCD monitor will display unchanging static content.
Need help?
Do you have a question about the 200V4Q and is the answer not in the manual?
Questions and answers