TABLE OF CONTENTS Section Title Page Section Title Page GENERAL 1-3. Camera System Adjustments ........5-9 ..............1-1 1. 28 MHz Origin Oscillation Adjustment ..... 5-9 2. Picture Frame Setting ..........5-10 3. Color Reproduction Adjustment ....... 5-11 DISASSEMBLY 4. Auto White Balance Reference Data Input ....5-12 5.
CVX-V1/V1P SECTION 2 DISASSEMBLY Note: Follow the disassembly procedure in the numerical order given. 2-1. REMOVAL OF CABINET (LOWER) 2-3. REMOVAL OF CAMERA HEAD ASSEMBLY ASSEMBLY, CS-53 BOARD 2 Camera head assembly 1 Two tapping screws 3 Claw 9 Tapping screw...
2-4. REMOVAL OF LENS (CCD) ASSEMBLY 2 Two screws (P2) Note 1: When remove a connector, don't pull at 3 Cabinet wire of connector. (upper) Be in danger of the snapping of a wire. 5 Screw (M1.7 × 3) 6 Two connectors (CN101, 102) (Note1, 2) 7 Connection cord...
CVX-V1/V1P CD-188 (CCD IMAGER), (TIMING GENERATOR) SCHEMATIC DIAGRAM CD-188 BOARD (2/2) 7 Vp-p IC101 @∞, @§ 7 Vp-p IC101 @•, #¡ 3 Vp-p IC101 $¢ 3 Vp-p IC101 $∞ CD-188 BOARD (1/2) Precautions for Replacement of CCD Imager • The CD-188 board mounted as a repair part is not equipped with a CCD imager.
Page 14
CVX-V1/V1P CS-53 (CAMERA, Y/C PROCESS, MIC AMP, MODE CONTROL) PRINTED WIRING BOARD – Ref. No.: CS-53 board; 1,000 series – • For printed wiring board. There are few cases that the part isn't mounted in this model is printed on this diagram.
CVX-V1/V1P CVX-V1/V1P CS-53 (MIC AMP) SCHEMATIC DIAGRAM • See page 4-11 for CS-53 BOARD printed wiring board. MIC AMP CS-53 (3/3) 4-23 4-24...
Page 18
CVX-V1/V1P • For printed wiring boards. There are few cases that the part isn't mounted in this model is printed on this diagram. • VA-103 board is 4-layers print board. However, the patterns of VA-103 (DC-DC CONVERTER, VIDEO/AUDIO I/O, LANC I/O), IF-69 (INTERFACE) PRINTED WIRING BOARDS layers 2 to 3 have not been included in the diagram.
CVX-V1/V1P SECTION 5 ADJUSTMENTS 5-1. CAMERA SECTION ADJUSTMENT NTSC model: CVX-V1 PAL model : CVX-V1P 1-1. PREPARATIONS BEFORE ADJUSTMENT 1-1-1. List of Service Tools • Oscilloscope • Regulated power supply • Vectorscope • Frequency counter • Color monitor • Digital voltmeter Ref.
1-1-2. Preparations Note 1: For details of how remove the cabinet and boards, refer Pattern box to “2. DISASSEMBLY”. 1) Connect the equipment for adjustments according to Fig. 5-1-3. 2) Connect the adjustment remote commander to the CN805 on the VA-103 board via CPC-5 (J-6082-351-A). Front side of the lens L = About 40 cm Fig.
1-1-3. Precaution 1. Setting the Switch Unless otherwise specified, set the switches as follows and per- form adjustments. 1. POWER switch (Control switch block) ....ON 2. AE LOCK switch (Control switch block) ... OFF 2. Order of Adjustments Basically carry out adjustments in the order given. Electronic beam scanning frame 0 ±...
1-1-4. ADJUSTMENT REMOTE COMMANDER 2. Precautions Upon Using The adjustment remote commander is used for changing the cal- The Adjustment Remote Commander culation coefficient in signal processing, EVR data, etc. The ad- Mishandling of the adjustment remote commander may erase the justment remote commander performs bi-directional communica- correct adjustment data at times.
1-1-5. DATA PROCESS The calculation of the DDS display and the adjustment remote commander display data (hexadecimal notation) are required for obtaining the adjustment data of some adjustment items. In this case, after converting the hexadecimal notation to decimal nota- tion, calculate and convert the result to hexadecimal notation, and use it as the adjustment data.
1-2. INITIALIZATION OF F PAGE DATA 3. F Page Table Note: Fixed data-1 : Initialized data. ( Refer to “1. Initializing 1. Initializing the F Page Data the F Page Data”.) Note: If the F page data has been initialized, “Modification of F Fixed data-2 : Modified data.
Page 28
Address Initial Remark Address Initial Remark value value NTSC PAL NTSC PAL Auto White Balance Fixed data1 3D Reference Data Input (Initialized data) Fixed data1 Picture Frame Setting Fixed data1 (Initialized data) Fixed data2 Fixed data1 28MHz Origin Oscillation Adj. Fixed data1 (Initialized data) Fixed data2...
Page 29
Address Initial Remark Address Initial Remark value value NTSC PAL NTSC PAL Fixed data2 Fixed data1 (Initialized data) Fixed data1 (Initialized data) FE Color Reproduction Adj. Fixed data2 Fixed data1 (Initialized data) Fixed data2 Fixed data1 (Initialized data) Fixed data2 Fixed data1 (Initialized data) Fixed data2...
1-3. CAMERA SYSTEM ADJUSTMENTS 1. 28 MHz Origin Oscillation Adjustment (CS-53 board) Set the frequency of the clock for synchronization. If deviated, the synchronization will be disrupted and the color will become in- consistent. Subject Not required Pin !™ of IC304 Measurement Point Measuring Instrument Frequency counter...
2. Picture Frame Setting Check on the oscilloscope Color bar chart standard picture frame Subject 1. Horizontal period (40 cm from the front of the lens) Measurement Point Video output terminal Measuring Instrument Oscilloscope and TV monitor Adjustment page Adjustment address 36, 37 Specified Value A = B, C = D, t = 0 ±...
3. Color Reproduction Adjustment For NTSC model Adjust the color Separation matrix coefficient so that proper color reproduction is produced. Color bar chart standard picture Subject frame Measurement Point Video output terminal Measuring Instrument Vectorscope Adjustment Page Adjustment Address 44, 46, AA, AB Specified Value All color luminance points should settle within each color reproduc-...
4. Auto White Balance Reference Data Input 5. Auto White Balance Adjustment Adjust to the proper auto white balance output data. Clear chart Subject If it is not correct, auto white balance and color reproducibility (Color bar standard picture frame) will be poor.
6. White Balance Check Clear chart Subject (Color bar standard picture frame) Filter C14 for color temperature Filter correction ND filter 1.0 and 0.3 Measurement Point Video output terminal Measuring Instrument Vectorscope Specified Value Fig. 5-1-10. (A) to (C) Checking method: Fig.
7. Battery Down Adjustment 11) Select page: F, address: 5B, set data: X , and press the PAUSE Set the battery end voltage. button of the adjustment remote commander. 12) Select page: F, address: 5C, set data: X , and press the PAUSE Mode Camera on button of the adjustment remote commander.
Page 43
FOR CAMERA COLOR REPRODUCTION ADJUSTMENT Take a copy of CAMERA COLOR For NTSC model REPRODUCTION FRAME and Parts reference sheets with a clear sheet for use. CVX-V1 For PAL model CVX-V1P...
Page 44
You can find the parts position of mount locations applying to VA-103 board of a set. S I D E B CN801 VA-103 BOARD I C 6 0 1 CN802 CN601 IC702 CN803 I C 6 0 2 CN804 I C 8 0 1 SIDE A CVX-V1/ V1P...