• To use this unit correctly and safely, be sure to read these operating
instructions before use.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Mr. SLIM MSY-JS18VF and is the answer not in the manual?

Questions and answers

Summary of Contents for Mitsubishi Electric Mr. SLIM MSY-JS18VF

  • Page 1 SPLIT-TYPE AIR CONDITIONERS INDOOR UNIT MSY-JS18VF MSY-JS24VF OPERATING INSTRUCTIONS For user English • To use this unit correctly and safely, be sure to read these operating instructions before use.
  • Page 2: Table Of Contents

    ● OPERATING INSTRUCTIONS ● ONTENTS SAFETY PRECAUTIONS NAME OF EACH PART PREPARATION BEFORE OPERATION SELECTING OPERATION MODES FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT FAST COOLING OPERATION SLEEP OPERATION TIMER OPERATION (ON/OFF TIMER) EMERGENCY OPERATION AUTO RESTART FUNCTION CLEANING WHEN YOU THINK THAT TROUBLE HAS OCCURRED ERROR CODE DISPLAY MODE WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME INSTALLATION PLACE AND ELECTRICAL WORK...
  • Page 3 AFETY PRECAUTIONS Meanings of symbols used in this manual : Be sure not to do. : Danger of electric shock. Be careful. : Be sure to disconnect the power supply plug : Be sure to follow the instruction. from the power outlet. : Never insert your fi...
  • Page 4 ● OPERATING INSTRUCTIONS ● AFETY PRECAUTIONS WARNING The user should never attempt to wash the inside of the indoor unit. Should the inside of the unit require cleaning, contact your dealer. • Unsuitable detergent may cause damage to plastic material inside the unit, which may result in water leakage.
  • Page 5 AFETY PRECAUTIONS CAUTION Ensure that the area is well-ventilated when the unit is operated together with a combustion appliance. • Inadequate ventilation may cause oxygen starvation. Turn the breaker OFF when you hear thunder and there is a possibility of a lightning strike. •...
  • Page 6: Name Of Each Part

    ● OPERATING INSTRUCTIONS ● AME OF EACH PART Indoor unit Front panel Heat exchanger Air inlet Air fi lter (Anti mold fi lter) Air cleaning fi lter (Microparticle catching fi lter) (Electrostatic anti-allergy enzyme fi lter, option) Air outlet Horizontal vane Remote control receiving section Operation indicator lamp Emergency operation switch...
  • Page 7: Preparation Before Operation

    REPARATION AME OF EACH PART BEFORE OPERATION Remote controller Before operation: Insert the power supply plug into the power outlet and/or turn the breaker on. Signal transmitting section Installing the remote control- Distance of signal : About 6 m Beep(s) is (are) heard from the indoor unit when the signal is ler batteries received.
  • Page 8: Selecting Operation Modes

    ● OPERATING INSTRUCTIONS ● ELECTING OPERATION MODES Note: Operation indicator lamp The operation indicator lamp shows the operation state of the unit. Indication Operation state Room temperature The unit is operat- About 2°C or more ing to reach the set away from set tem- temperature perature...
  • Page 9: Fan Speed And Airflow Direction Adjustment

    AN SPEED AND AIRFLOW DIRECTION ADJUSTMENT Up-down Airflow direction Press to select airfl ow direc- tion. Each press changes airfl ow direction in the following order: (AUTO) (SWING) (AUTO) ..The vane is set to the most effi cient airfl ow direction. :horizontal position. (Manual) ..For effi...
  • Page 10: Fast Cooling Operation

    ● OPERATING INSTRUCTIONS ● AST COOLING OPERATION LEEP OPERATION Press during COOL Press during COOL mode page 7 to start SLEEP opera- mode page 7 to start FAST COOL- tion. ING operation. • Set temperature will change over time. Fan speed : Exclusive speed for FAST •...
  • Page 11: Timer Operation (On/Off Timer)

    IMER OPERATION MERGENCY OPERATION (ON/OFF TIMER) When the remote controller cannot be used... Emergency operation can be activated by pressing the emergency operation switch (E.O. SW) on the indoor unit. Each time the E.O. SW is pressed, the operation changes in the fol- lowing order: Operation indicator lamp Emergency COOL...
  • Page 12: Cleaning

    ● OPERATING INSTRUCTIONS ● LEANING Instructions: • Switch off the power supply or turn off the breaker before cleaning. • Be careful not to touch the metal parts with your hands. • Do not use benzine, thinner, polishing powder, or insecticide. •...
  • Page 13 LEANING Air fi lter (Anti mold fi lter) Clean every 2 weeks • • Remove dirt by a vacuum cleaner, or rinse with water. • After washing with water, dry it well in shade. Air cleaning fi lter (Microparticle catching fi lter) Removes the microparticles from the air by means of static electricity.
  • Page 14: When You Think That Trouble Has Occurred

    ● OPERATING INSTRUCTIONS ● HEN YOU THINK THAT TROUBLE HAS OCCURRED Even if these items are checked, when the unit does not recover from the trouble, stop using the air condi- tioner and consult your dealer. Symptom Explanation & Check points Indoor Unit The unit cannot be operated.
  • Page 15 HEN YOU THINK THAT TROUBLE HAS OCCURRED Symptom Explanation & Check points Does not cool The room cannot be cooled suffi ciently. • Is the temperature setting appropriate? Page 7 • Is the fan setting appropriate? Please change fan speed to High or Super High.
  • Page 16: Error Code Display Mode

    ● OPERATING INSTRUCTIONS ● RROR CODE DISPLAY MODE Error code can be checked on the display of remote controller while the upper operation indicator lamp on the indoor unit is blinking. Follow the procedure below to check the error code. Error code check Press to change an error code.
  • Page 17 RROR CODE DISPLAY MODE Error code of remote controller Object Code Abnormal point None (Normal) Indoor unit Serial signal Indoor control system Room temperature thermistor Indoor coil thermistor Indoor fan motor Outdoor unit Indoor/outdoor communication, receiving error Nonvolatile memory data Different voltage 4-way valve/Pipe temperature Outdoor refrigerant system...
  • Page 18: When The Air Conditioner Is Not Going To Be Used For A Long Time

    ● OPERATING INSTRUCTIONS ● HEN THE AIR CONDITIONER IS NOT NSTALLATION PLACE GOING TO BE USED FOR A LONG TIME AND ELECTRICAL WORK Installation place Operate by COOL mode with the Avoid installing the air conditioner in the following highest temperature set or FAN places.
  • Page 19: Specifications

    PECIFICATIONS Guaranteed operating range Indoor Outdoor 32°C DB 46°C DB Upper limit 23°C WB — 21°C DB 21°C DB Lower limit 15°C WB — DB: Dry Bulb WB: Wet Bulb En-18...
  • Page 20: Peringatan Keselamatan

    ● ARAHAN PENGENDALIAN ● ANDUNGAN PERINGATAN KESELAMATAN NAMA SETIAP BAHAGIAN PERSEDIAAN SEBELUM PENGENDALIAN MEMILIH MOD OPERASI KELAJUAN KIPAS DAN PELARASAN ARAH ALIRAN UDARA OPERASI PENYEJUKAN PANTAS OPERASI SLEEP OPERASI PEMASA (PEMASA ON/OFF) OPERASI KECEMASAN FUNGSI MULA SEMULA AUTO PEMBERSIHAN APABILA ANDA FIKIR MASALAH BERLAKU MOD PAPARAN KOD RALAT APABILA PENYAMAN UDARA TIDAK AKAN DIGUNAKAN UNTUK TEMPOH YANG LAMA TEMPAT PEMASANGAN DAN KERJA ELEKTRIK...
  • Page 21 ERINGATAN KESELAMATAN Maksud simbol yang digunakan dalam manual ini : Pastikan anda tidak melakukannya. : Bahaya kejutan elektrik. Berhati-hati. : Pastikan anda menanggalkan palam bekalan : Pastikan anda mengikuti arahan. kuasa dari soket dinding. : Jangan sesekali memasukkan jari atau kayu, dll. : Pastikan anda mematikan bekalan kuasa.
  • Page 22 ● ARAHAN PENGENDALIAN ● ERINGATAN KESELAMATAN AMARAN Pengguna tidak boleh sesekali cuba mencuci bahagian dalam unit dalaman. Sekiranya bahagian dalam unit ini perlu dibersihkan, sila hubungi wakil penjual anda. • Bahan pencuci yang tidak sesuai boleh menyebabkan kerosakan kepada bahan plastik di dalam unit ini, yang boleh menyebabkan kebocoran air.
  • Page 23 ERINGATAN KESELAMATAN AWAS Pastikan kawasan itu mempunyai sistem pengudaraan yang baik apabila unit ini dikendalikan bersama dengan perkakas pembakaran. • Pengudaraan yang tidak mencukupi boleh menyebabkan kekurangan oksigen. MATIKAN pemutus apabila anda mendengar guruh dan apabila terdapat kemungkinan dipanah kilat. •...
  • Page 24: Nama Setiap Bahagian

    ● ARAHAN PENGENDALIAN ● AMA SETIAP BAHAGIAN Unit dalaman Panel depan Penukar haba Saluran masuk Penapis udara udara (Penapis anti kulapuk) Penapis pembersih udara (Penapis penangkap partikel mikro) (Penapis enzim anti alahan elektrostatik, pilihan) Salur keluar udara Ram melintang Bahagian penerima isyarat kawalan jauh Lampu penunjuk operasi Suis operasi kecemasan Halaman 10...
  • Page 25: Persediaan Sebelum Pengendalian

    ERSEDIAAN SEBELUM AMA SETIAP BAHAGIAN PENGENDALIAN Alat kawalan jauh Sebelum operasi: Cucukkan palam bekalan kuasa ke soket bekalan kuasa dan/atau hidupkan pemutus. Bahagian yang menghantar isyarat. Memasang bateri alat kawalan Jarak isyarat : Lebih kurang 6 m jauh Bunyi 'bip' kedengaran dari unit dalaman apabila isyarat diterima. * Rujuk halaman 15 untuk MOD PAPARAN KOD RALAT.
  • Page 26: Memilih Mod Operasi

    ● ARAHAN PENGENDALIAN ● EMILIH MOD OPERASI Nota: Lampu penunjuk operasi Lampu penunjuk operasi menunjukkan keadaan operasi unit. Penunjuk Keadaan operasi Suhu bilik Unit ini beroperasi Lebih kurang 2°C untuk mencapai suhu atau lebih daripada yang ditetapkan suhu tetapan Suhu bilik sedang Lebih kurang 1 menghampiri suhu hingga 2°C daripada...
  • Page 27: Kelajuan Kipas Dan Pelarasan Arah Aliran Udara

    ELAJUAN KIPAS DAN PELARASAN ARAH ALIRAN UDARA Arah Aliran Udara Ke Bawah Tekan untuk memilih arah aliran udara. Setiap kali anda menekannya, arah aliran udara akan bertukar dalam urutan berikut: (AUTO) (AYUN) (AUTO) ..Ram ditetapkan kepada arah aliran udara yang paling cekap. : kedudukan melintang.
  • Page 28: Operasi Penyejukan Pantas

    ● ARAHAN PENGENDALIAN ● PERASI PENYEJUKAN PANTAS PERASI SLEEP Tekan semasa mod SEJUK halaman 7 Tekan semasa dalam mod untuk memulakan operasi SLEEP. COOL halaman 7 untuk memulakan operasi PENYEJUKAN PANTAS. • Suhu yang ditetapkan akan berubah dari masa ke masa. •...
  • Page 29: Operasi Pemasa (Pemasa On/Off)

    PERASI PEMASA PERASI KECEMASAN (PEMASA ON/OFF) Apabila alat kawalan jauh tidak boleh digunakan... Operasi kecemasan boleh diaktifkan dengan menekan suis operasi kecemasan (E.O. SW) pada unit dalaman. Setiap kali E.O. SW ditekan, operasi akan bertukar dalam urutan berikut: Lampu penunjuk operasi COOL Kecemasan Berhenti Suhu tetapan : 24°C...
  • Page 30: Pembersihan

    ● ARAHAN PENGENDALIAN ● EMBERSIHAN Arahan: • Matikan bekalan kuasa atau matikan pemutus sebelum membersihkan unit ini. • Berhati-hati agar tidak menyentuh komponen berlogam dengan tangan anda. • Jangan gunakan benzena, larutan pencair, serbuk penggilap atau pembunuh serangga. • Hanya gunakan detergen neutral yang telah dicairkan. •...
  • Page 31 EMBERSIHAN Penapis udara (Penapis anti kulapuk) Bersihkan setiap 2 minggu • • Buangkan kotoran menggunakan pembersih hampagas, atau bilas dengan air. • Selepas mencucinya dengan air, keringkan di tempat yang teduh. Penapis pembersih udara (Penapis penangkap partikel mikro) Keluarkan partikel mikro dari udara secara elektrik statik. Bahagian belakang penapis udara Setiap 3 bulan: •...
  • Page 32: Apabila Anda Fikir Masalah Berlaku

    ● ARAHAN PENGENDALIAN ● PABILA ANDA FIKIR MASALAH BERLAKU Walaupun jika item-item ini sudah diperiksa, jika unit ini tidak pulih daripada masalahnya, berhenti menggunakan penyaman udara ini dan sila berunding dengan wakil penjual anda. Simptom Penjelasan & Perkara semakan Unit Dalaman Unit ini tidak boleh dikendalikan.
  • Page 33 PABILA ANDA FIKIR MASALAH BERLAKU Simptom Penjelasan & Perkara semakan Tidak menyejukkan Bilik tidak boleh disejukkan secukupnya. • Adakah tetapan suhu betul? Halaman 7 • Adakah tetapan kipas betul? Sila tukar kelajuan kipas ke High (Tinggi) atau Super High (Sangat Tinggi). Halaman 8 •...
  • Page 34: Mod Paparan Kod Ralat

    ● ARAHAN PENGENDALIAN ● OD PAPARAN KOD RALAT Kod ralat boleh diperiksa pada paparan alat kawalan jauh manakala lampu penunjuk operasi bahagian atas unit dalaman berkelip. Sila ikuti prosedur di bawah untuk memeriksa kod ralat. Periksa kod ralat Tekan atau untuk mengubah kod ralat.
  • Page 35 OD PAPARAN KOD RALAT Kod ralat untuk alat kawalan jauh Objek Bahagian Bermasalah Tiada (Normal) Unit dalaman Isyarat siri Sistem kawalan dalaman Termistor suhu bilik Termistor gegelung dalaman Motor kipas dalaman Unit luaran Komunikasi dalaman/luaran, menerima ralat Data ingatan tidak berubah Voltan berbeza Injap 4-cara/Suhu paip Sistem penyejuk luaran...
  • Page 36: Apabila Penyaman Udara Tidak Akan Digunakan Untuk Tempoh Yang Lama

    ● ARAHAN PENGENDALIAN ● PABILA PENYAMAN UDARA TIDAK AKAN EMPAT PEMASANGAN DIGUNAKAN UNTUK TEMPOH YANG LAMA DAN KERJA ELEKTRIK Tempat pemasangan Kendalikan dengan mod COOL pada Elakkan daripada memasang penyaman udara di tetapan suhu tertinggi atau mod FAN tempat-tempat berikut. •...
  • Page 37: Spesifikasi

    PESIFIKASI Julat kendalian yang dijamin Dalaman Luaran 32°C DB 46°C DB Had atas 23°C WB — 21°C DB 21°C DB Had bawah 15°C WB — DB: Bebuli Kering WB: Bebuli Basah Ms-18...
  • Page 56 HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN VG79Y117H01...

This manual is also suitable for:

Mr. slim msy-js24vf

Table of Contents