SPLIT-TYPE AIR CONDITIONERS
INDOOR UNIT
MSZ-AP60VG
MSZ-AP60VGK
MSZ-AP71VG
MSZ-AP71VGK
OPERATING INSTRUCTIONS
English

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MSZ-AP71VG and is the answer not in the manual?

Questions and answers

Summary of Contents for Mitsubishi Electric MSZ-AP71VG

  • Page 1 SPLIT-TYPE AIR CONDITIONERS INDOOR UNIT MSZ-AP60VG MSZ-AP71VG MSZ-AP60VGK MSZ-AP71VGK OPERATING INSTRUCTIONS English...
  • Page 2 ● OPERATING INSTRUCTIONS ● ENGLISH IS ORIGINAL ONTENTS I SAFETY PRECAUTIONS I DISPOS AL I NAME OF EACH PART I PREPARATION BEFORE OPERATION I SELECTING OPERATION MODES I FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT I LONG OPERATION I POWERFUL OPERATION I I-SAVE OPERATION I ECONO COOL OPERATION I NIGHT MODE OPERATION...
  • Page 3: Safety Precautions

    To use this unit correctly and safely, be sure to read these operating instructions before use. AFETY PRECAUTIONS The unit should not be installed, relocated, disassembled, altered, Do not charge or disassemble the batteries, and do not throw them or repaired by the user. into a fi...
  • Page 4 It can cause malfunctions. ISPOSAL To dispose of this product, consult your dealer. Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and/or reused. This symbol means that electrical and electronic equipment, batteries and...
  • Page 5: Indoor Unit

    AME OF EACH PART Indoor unit Remote controller Battery replacement indicator Signal transmitting Page 5 Air inlet section Front panel Distance of signal : Operation dis- About 6 m play section Wi-Fi interface Beep(s) is (are) heard from Page 13 the indoor unit when the signal is received.
  • Page 6: Preparation Before Operation

    ● OPERATING INSTRUCTIONS ● REPARATION BEFORE OPERATION Before operation: Insert the power supply plug into the power outlet and/or Setting current time turn the breaker on. Installing the remote controller batteries Press the DAY button to set the day. Press RESET. Press CLOCK.
  • Page 7: Selecting Operation Modes

    ELECTING OPERATION MODES DRY mode Dehumidify your room. The room may be cooled slightly. Temperature cannot be set during DRY mode. HEAT mode Enjoy warm air at your desired temperature. FAN mode Circulate the air in your room. Note: After COOL/DRY mode operation, it is recommended to operate in the FAN mode to dry inside the indoor unit.
  • Page 8 ● OPERATING INSTRUCTIONS ● AN SPEED AND AIRFLOW DIRECTION ADJUSTMENT Up-down Airflow direction to select airfl ow direction. Each press Press changes airfl ow direction in the following order: (AUTO) (SWING) (AUTO) ..The vane is set to the most effi cient airfl ow direction. COOL/ DRY/FAN: horizontal position.
  • Page 9: Save Operation

    ONG OPERATION -SAVE OPERATION A simplifi ed set back function enables to recall the preferred (preset) setting with a single push of the button. Press the button again to start LONG operation. Press and you can go back to the previous setting in an instance. •...
  • Page 10: Econo Cool Operation

    ● OPERATING INSTRUCTIONS ● CONO COOL OPERATION IGHT MODE OPERATION NIGHT MODE operation changes the brightness of the operation Swing airfl ow (change of airfl ow) makes you feel cooler than station- indicator, disables the beep sound and limits the noise level of the ary airfl...
  • Page 11: Emergency Operation

    IMER OPERATION (ON/OFF TIMER) MERGENCY OPERATION When the remote controller cannot be used... Emergency operation can be activated by pressing the emergency operation switch (E.O. SW) on the indoor unit. Each time the E.O. SW is pressed, the operation changes in the following order: Operation indicator lamp Emergency COOL...
  • Page 12: Weekly Timer Operation

    ● OPERATING INSTRUCTIONS ● EEKLY TIMER OPERATION • A maximum of 4 ON or OFF timers can be set for individual days of the week. • A maximum of 28 ON or OFF timers can be set for a week. Press , and to set ON/OFF, time, and...
  • Page 13: Front Panel

    LEANING Instructions: • Switch off the power supply or turn off the breaker before cleaning. • Do not soak or rinse the horizontal vane. • Be careful not to touch the metal parts with your hands. • Do not use water hotter than 50°C. •...
  • Page 14 (ii) system or product fault; or (iii) loss or damage to any system or product; operation. which is caused by or arises from connection to and/or use of any third party Wi-Fi interface or any third party Wi-Fi service with Mitsubishi Electric equipment. For the latest information regarding MELCloud from Mitsubishi Electric Corporation, please visit www.melcloud.com.
  • Page 15 HEN YOU THINK THAT TROUBLE HAS OCCURRED Symptom Explanation & Check points Even if these items are checked, when the unit does not recover from the Remote controller trouble, stop using the air conditioner and consult your dealer. The display on the remote •...
  • Page 16: When You Think That Trouble Has Occurred

    ● OPERATING INSTRUCTIONS ● HEN YOU THINK THAT NSTALLATION PLACE AND TROUBLE HAS OCCURRED ELECTRICAL WORK In the following cases, stop using the air conditioner and consult your dealer. Installation place • When water leaks or drips from the indoor unit. Avoid installing the air conditioner in the following places.
  • Page 17: Specifications

    PECIFICATIONS Indoor MSZ-AP60VG(K) MSZ-AP71VG(K) Model Outdoor MUZ-AP60VG MUZ-AP71VG Cooling Cooling Function Heating Heating Power supply ~ /N, 230 V, 50 Hz Capacity 1.59 1.67 2.01 2.12 Input Indoor Weight Outdoor Refrigerant fi lling capacity (R32) 1.05 1.50 IP 20 Indoor...
  • Page 18: Меры Предосторожности

    ● ИНСТРУКЦИИ ПО ЭКСПЛУАТАЦИИ ● ПЕРЕВОД ОРИГИНАЛА С ОДЕРЖАНИЕ МЕРЫ ПРЕДОСТОРОЖНОСТИ УТИЛИЗАЦИЯ НАЗВАНИЯ ОТДЕЛЬНЫХ ЧАСТЕЙ ПРИБОРА ПОДГОТОВКА ПРИБОРА К ЭКСПЛУАТАЦИИ ВЫБОР РЕЖИМОВ РАБОТЫ НАСТРОЙКА СКОРОСТИ ВЕНТИЛЯТОРА И НАПРАВЛЕНИЯ ВОЗДУШНОГО ПОТОКА РЕЖИМ LONG (ДЛИННАЯ СТРУЯ) РЕЖИМ POWERFUL OПЕРАЦИЯ I-SAVE ФУНКЦИЯ ECONO COOL РЕЖИМ...
  • Page 19 MADE IN THAILAND HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN JG79Y567H02...