All manuals and user guides at all-guides.com SPLIT-TYPE, AIR CONDITIONERS No. OB325 SERVICE MANUAL Wireless type Models MS-A18WV - ( WH ) MS-A24WV - ( WH ) MS-A30WV - ( WH ) CONTENTS 1. TECHNICAL CHANGES ····································2 2. PART NAMES AND FUNCTIONS······················2 3.
All manuals and user guides at all-guides.com TECHNICAL CHANGES MS-18RV - MS-A18WV - 1. Indoor unit model has changed. 2. Rated voltage has changed. (220V-240V 230V) 3. Remote controller has changed. • LONG MODE and WIDE MODE have been added. 4.
Page 3
All manuals and user guides at all-guides.com REMOTE CONTROLLER MS-A18WV - MS-A24WV - MS-A30WV - Signal transmitting section Operation display section OPERATE/ STOP (ON/ OFF)button ON/OFF WARM COOL TEMPERATURE buttons Indication of remote controller model is on back. Open the front lid. CLOCK ON/OFF WARM...
All manuals and user guides at all-guides.com SPECIFICATION Indoor model MS-A18WV - MS-A24WV - Cooling Cooling Function Single phase Single phase Power supply 230V, 50Hz 230V, 50Hz Capacity Air flow(High/Med. /Low ) K /h 768/642 /528 768/672 /588 Power outlet Running current 0.30 0.30...
All manuals and user guides at all-guides.com NOISE CRITERIA CURVES MS-A18WV- MS-A24WV- FAN SPEED SPL(dB(A)) LINE FAN SPEED SPL(dB(A)) LINE High High Test conditions, Test conditions, Cooling : Dry-bulb temperature 27: Wet-bulb temperature 19: Cooling : Dry-bulb temperature 27: Wet-bulb temperature 19: NC-70 NC-70 NC-60...
All manuals and user guides at all-guides.com OUTLINES AND DIMENSIONS MS-A18WV - Unit: mm MS-A24WV - MS-A30WV - INDOOR UNIT Installation plate Indoor unit 1068 414.5 414.5 Wall hole [ 75 1100 Liquid line [ 6.35- 0.5m Installation plate Gas line [ 12-0.43m Insulation [ 50 O.D [ 32 I.D for MS-A18/A24WV...
All manuals and user guides at all-guides.com WIRING DIAGRAM MS-A18WV - MS-A24WV - MODELS WIRING DIAGRAM INDOOR UNIT TO OUTDOOR UNIT CN202 CONNECTING HIC1 RT12 CN112 CN201 NR11 TRANS SR141 TAB12 POWER SUPPLY CN211 CORD ELECTRONIC CONTROL ~/N 230V RT11 P.
All manuals and user guides at all-guides.com MICROPROCESSOR CONTROL MS-A18WV - MS-A24WV - MS-A30WV - WIRELESS REMOTE CONTROLLER Signal transmitting section Operation display section OPERATE/ STOP (ON/ OFF)button ON/OFF WARM COOL TEMPERATURE buttons CLOCK ON/OFF WARM COOL VANE button FAN SPEED CONTROL button STOP (Horizontal vane button) I FEEL COOL...
Page 10
All manuals and user guides at all-guides.com • Once the mode is fixed, the mode does not change by room temperature afterwards. • Under the ON-TIMER ( ) operation, mode is determined according to the room temperature at the set time the operation starts.
Page 11
All manuals and user guides at all-guides.com 8-1-1. COOL mode of “I FEEL CONTROL” 1. Indoor fan speed control Indoor fan operates at the set speed by FAN SPEED CONTROL button. Difference between room In AUTO the fan speed is as follows. temperature and set temperature during operation Initial temperature difference...
Page 12
All manuals and user guides at all-guides.com Operation time chart Example Thermostat Indoor fan Outdoor fan Compressor 8 min. 1 min. 3 min. 4 min. 3. Coil frost prevention • The operation is as same as coil frost prevention during COOL mode of “I FEEL CONTROL”. •...
Page 13
All manuals and user guides at all-guides.com 8-5. INDOOR FAN MOTOR CONTROL (1) Rotational frequency feedback control The indoor fan motor is equipped with a rotational frequency sensor, and outputs signal to the microprocessor to feedback the rotational frequency. Comparing the current rotational frequency with the target rotational frequency (High, Med., Low), the microprocessor controls SR141 and adjusts fan motor electric current to make the current rota- tional frequency close to the target rotational frequency.
Page 14
All manuals and user guides at all-guides.com (8) ECONO COOL ( ) operation (ECONOmical operation) When the ECONO COOL button is pressed in COOL mode, set temperature is automatically set 2°C higher than that in COOL mode. Also the horizontal vane swings in various cycle according to the temperature of indoor heat exchanger(Tp (w 1) SWING operation makes you feel cooler than set temperature.
Page 15
All manuals and user guides at all-guides.com 2. Vertical vane (1) Vane motor drive These models are equipped with a stepping motor for the vertical vane. The rotating direction, speed, and angle of the motor are controlled by pulse signals (approx. 12V) transmitted from microprocessor. (2) The vertical vane angle and mode change as follows by pressing the WIDE VANE button.
Page 16
All manuals and user guides at all-guides.com 2. Cancel TIMER setting can be cancelled with the ON/OFF TIMER buttons. To cancel the ON timer, press the “ON-TIMER” button. To cancel the OFF timer, press the “OFF-TIMER” button. TIMER is cancelled and the display of set time disappears. PROGRAM TIMER •...
All manuals and user guides at all-guides.com SERVICE FUNCTIONS MS-A18WV - MS-A24WV - MS-A30WV - 9-1. TIMER SHORT MODE For service, set time can be shortened by short circuit of JPG and JPS on the electronic control P.C. board. The time will be shortened as follows. Set time : 1 minute 1-second Set time : 3 minute...
Page 18
All manuals and user guides at all-guides.com Table 1 1 unit operation 2 units operation 3 units operation 4 units operation Same as at left No. 1 unit No modification Same as at left Same as at left No. 2 unit –...
All manuals and user guides at all-guides.com TROUBLESHOOTING MS-A18WV - MS-A24WV - MS-A30WV - 10-1. Cautions on troubleshooting 1. Before troubleshooting, check the following: (1) Check the power supply voltage. (2) Check the indoor/outdoor connecting wire for mis-wiring. 2. Take care the following during servicing. (1) Before servicing the air conditioner, be sure to first turn off the remote controller to stop the main unit, and then after confirming the horizontal vane is closed, turn off the breaker and / or disconnect the power plug.
Page 20
All manuals and user guides at all-guides.com 10-2. Instruction of troubleshooting Start Indoor unit Indoor unit Indoor unit operates. OPERATION INDICATOR operates. doesn't receive Outdoor unit lamp on the indoor unit is Outdoor unit the signal from doesn't operate flashing on and off. doesn't remote controller.
Page 21
All manuals and user guides at all-guides.com 1. Troubleshooting check table • The following indication applies regardless of shape of the indicator. flashing · Flashing of the OPERATION INDICATOR lamp (on the left-hand side) indicates possible Operation Indicator abnormalities. · The OPERATION INDICATOR lamp (on the left-hand side) is lighted during normal operation. Before taking measures, make sure that the symptom reappears, for accurate troubleshooting.
Page 22
All manuals and user guides at all-guides.com 2. Trouble criterion of main parts MS-A18WV - MS-A24WV - MS-A30WV - Figure Part name Check method and criterion Room temperature Measure the resistance with a tester. (Part temperature 10˚C ~ 30˚C) thermistor(RT11) Normal Abnormal Indoor coil thermistor...
Page 23
All manuals and user guides at all-guides.com When OPERATION INDICATOR lamp flashes 3-time. Indoor fan motor doesn’t operate. Check of indoor fan motor Turn OFF the power supply. Check connector CN211 visually. Is soldered point of the connector Are lead wires connected? Resolder it.
Page 24
All manuals and user guides at all-guides.com The unit doesn’t operate with the remote controller. Also, the OPERATION INDICATOR lamp doesn’t light up by press- ing the EMERGENCY OPERATION switch. Check of indoor electronic control P.C. board Check the both “parts side” and “pattern Varistor (NR11) side”...
Page 25
All manuals and user guides at all-guides.com When OPERATION INDICATOR lamp flashes ON and OFF in every 0.5-second. Outdoor unit doesn’t operate. How to check mis-wiring MS-A30WV w Short circuit of JPG and JPS on the indoor electronic control P.C. board enables self -check to be displayed in 3 seconds. Start •...
Page 26
All manuals and user guides at all-guides.com TEST POINT DIAGRAM AND VOLTAGE MS-A18WV - MS-A24WV - MS-A30WV - Indoor electronic control P.C. board Fan motor power supply Power supply input 230V AC 5V DC Fuse (F11) 250V AC 3.15A Room temperature ther- mistor(RT11) R132 Indoor coil...
All manuals and user guides at all-guides.com DISASSEMBLY INSTRUCTIONS <"Terminal with lock mechanism" Detaching points> In case of terminal with lock mechanism, detach the terminal as shown below. There are two types ( Refer to (1) and (2)) of the terminal with lock mechanism. The terminal with no lock mechanism can be removed by pulling it out.
Page 28
All manuals and user guides at all-guides.com OPERATING PROCEDURE PHOTOS 3. Removing the electrical box Photo 3 Screws of the ground wire (1) Remove the front panel. (Refer to 1.) (2) Remove the electrical cover. (Refer to 2.) (3) Disconnect the connector of the indoor coil thermistor. (4) Disconnect the motor connector (CN211 and CN121) and the vane motor connector (CN151) on the electronic control P.C.
All manuals and user guides at all-guides.com PARTS LIST MS-A18WV - (WH) MS-A24WV - (WH) MS-A30WV - (WH) 12-1. INDOOR UNIT STRUCTURAL PARTS 12-2. INDOOR UNIT HEAT EXCHANGER CATCH Optional parts SCREW (See page 31.) 12-1. INDOOR UNIT STRUCTURAL PARTS Part number that is circled is not shown in the illustration.
Page 30
All manuals and user guides at all-guides.com MS-A18WV - (WH) MS-A24WV - (WH) MS-A30WV - (WH) 12-4. ACCESSORY AND 12-3. INDOOR UNIT FUNCTIONAL PARTS AND REMOTE CONTROLLER ELECTRICAL PARTS SLEEVE BEARING ROOM TEMPERATURE THERMISTOR 15 16 VARISTOR FUSE 12-3. INDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS Part numbers that are circled are not shown in the illustration.
All manuals and user guides at all-guides.com OPTIONAL PARTS AIR CLEANING FILTER AIR CLEANING FILTER removes fine dust of 0.01 micron from air by means of static electricity. Normal life of AIR CLEANING FILTER is 4 months. However, when it becomes dirty, replace it as soon as possible. Clogged AIR CLEANING FILTER may reduce the air conditioner capacity or cause frost on the air outlet.
Page 32
All manuals and user guides at all-guides.com HEAD OFFICE: MITSUBISHI DENKI BLDG.,2-2-3, MARUNOUCHI, CHIYODA-KU, TOKYO100-8310, JAPAN C C Copyright 2003 MITSUBISHI ELECTRIC ENGINEERING CO.,LTD Distributed in Dec. 2003. No.OB325 6 New publication, effective Dec. 2003 Made in Japan Specifications subject to change without notice.
Need help?
Do you have a question about the MS-A18WV-E1 WH and is the answer not in the manual?