Page 1
Hitachi Virtual Storage Platform G400, G600 83-05-2x Hardware Reference Guide This document provides information about the system hardware components, mechanical, and environmental specifications for the Hitachi Virtual Storage Platform G400 and VSP G600 storage systems. MK-94HM8022-15 March 2021...
Page 2
Hitachi, Ltd., or Hitachi Vantara LLC (collectively “Hitachi”). Licensee may make copies of the Materials provided that any such copy is: (i) created as an essential step in utilization of the Software as licensed and is used in no other manner;...
Preface This guide describes the hardware features and specifications of the VSP G400, G600 models. Intended audience This document is intended for Hitachi Vantara representatives, system administrators, authorized service providers, or customers who install, configure, and operate the storage system.
Read the release notes before installing and using this product. They may contain requirements or restrictions that are not fully described in this document or updates or corrections to this document. Release notes are available on Hitachi Vantara Support Connect: https://knowledge.hitachivantara.com/Documents.
Page 8
Provides helpful information, guidelines, or suggestions for performing tasks more effectively. Caution Warns the user of adverse conditions and/or consequences (for example, disruptive operations, data loss, or a system crash). Preface Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Getting help Hitachi Vantara Support Website is the destination for technical support of products and solutions sold by Hitachi Vantara. To contact technical support, log on to the Hitachi Vantara Support Website for contact information: https://support.hitachivantara.com/en_us/contact- us.html. Hitachi Vantara Community is a global online community for Hitachi Vantara customers, partners, independent software vendors, employees, and prospects.
■ VSP G400 model The VSP G400 is a highly reliable storage system that offers high storage capacity with full redundancy to better protect data and manage storage operations. The storage system consists of a 4U enclosure that includes two controllers and two NAS modules to support file operations.
Page 14
2.4 TB DKC-F810I-6R0H9M LFF disk drive 6 TB DKC-F810I-10RH9M LFF disk drive 10 TB Flash module drives The VSP G400 storage system supports the listed flash module drive capacities. Model number Drive type Drive capacity DKC-F810I-7R0FP 7 TB DKC-F810I-14RFP 14 TB Solid-state drives The VSP G400 storage system supports the listed SSD capacities.
1.9 TB DKC-F810I-3R8MGM 3.8 TB DKC-F810I-7R6MGM 7.6 TB Features The features described in the table are included with VSP G400 and VSP G600. Feature Value Maximum cache memory supported VSP G400:128 GB VSP G600: 256 GB Maximum number of spare drives...
Note: If a drive is inserted into a slot of a dense intermix drive tray when the installed number of drives exceeds 240 slots per path, the drive is blocked. Chapter 1: Hitachi Virtual Storage Platform G400, G600 hardware overview Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Chapter 2: Virtual Storage Platform G400, G600 controller The Virtual Storage Platform G400, G600 models are equipped with dual controllers for communicating with a data host. Each controller includes the following internal components such as a processor, dual in-line cache memory modules (DIMMs), cache flash memory (CFM), battery, and fans. The controller has an Ethernet connection for out-of-band management using Hitachi Device Manager - Storage Navigator.
(for example, BKMF-10 and BKMF-20). CBLM rear panel The following table describes the definitions of the CBLM controller rear panel LEDs. Chapter 2: Virtual Storage Platform G400, G600 controller Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Page 27
CBLM rear panel Number Item Power supply unit Front end module Back end module LAN blade Rear view (includes NAS modules) Chapter 2: Virtual Storage Platform G400, G600 controller Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
The controllers are equipped with specific interfaces for connecting, powering, configuring, and managing the storage system. The component LEDs display the operating status of the storage system. Front-end modules Chapter 2: Virtual Storage Platform G400, G600 controller Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Blue: Normal link status at 16-Gbps. Green: Normal link status at 4-Gbps or 8-Gbps. Fibre Channel connectors Connect to Fibre Channel cables. Chapter 2: Virtual Storage Platform G400, G600 controller Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Maintenance LAN port used by service personnel. LAN ALARM LED Red: LAN blade can be removed. Uninterruptible power supply (UPS) port Back-end modules Chapter 2: Virtual Storage Platform G400, G600 controller Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Page 32
PORT LED Blue: Link status is normal. PATH 0 connector Connect to a drive tray. PATH 1 connector Connects to a drive tray. Chapter 2: Virtual Storage Platform G400, G600 controller Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
DW-F800-DBSE 2U (88.2 mm) 2.5 inch (SFF) SFF with front panel bezel Number Item Description POWER LED Green: Drive tray is powered READY LED Green: Drive tray is operational. Chapter 3: Drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Can be turned on or ■ turned off by the maintenance utility. ALM LED Red: Drive stopped due to a failure and can be replaced. ACT LED Green: Normal operation. Chapter 3: Drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
ALARM LED Red: ENC can be replaced. PATH (IN) LED Blue: IN side port is linked PATH (IN) connector Connects to a controller or drive tray. Chapter 3: Drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
The DBSE and DBLE power supply has a Platinum efficiency rating. Number Item Description RDY LED Green: Normal operation. ACI IN LED Green: AC input is operating normally. Chapter 3: Drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
The following describes the physical specifications of the large form-factor drive tray. Number of Name Model name Height drive slots Drive type DW-F800-DBLC 2U (88.2 mm) 3.5 inch (LFF) DBLE DW-F800-DBLE 2U (88.2 mm) 3.5 inch (LFF) Chapter 3: Drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Locks and unlocks the front panel bezel by using the supplied key. LFF front panel without bezel Number Item Description POWER, READY, and Green: Drive tray is powered LOCATE LEDs Chapter 3: Drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
The slots are organized in the following order: LFF rear panel Number Item Description POWER LED Green: ENC is in the power- on state. Chapter 3: Drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
LEDs to display its operating status. Note: The DBS and DBL power supply has a Silver efficiency rating. The DBSE and DBLE power supply has a Platinum efficiency rating. Chapter 3: Drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
ALM LED Red: Power supply unit can be replaced. Flash module drive tray (DBF) The following describes the physical specifications of the flash module drive tray. Chapter 3: Drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Can be turned on or ■ turned off by the maintenance utility. Lock Locks and unlocks the front panel bezel by using the supplied key. Chapter 3: Drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Note: ACT indicator is only printed on some types of FMDs. POWER, READY, and Green: Drive tray is powered LOCATE LEDs Green: Drive tray is operational. Chapter 3: Drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Green: ENC is in the power- on state. Locate LED Amber: Indicates the location of ■ the chassis. Can be turned on or ■ turned off by the maintenance utility. Chapter 3: Drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
The following describes the physical specifications of the high-density drive tray. Number of Name Model name Height drive slots Drive type DB60 DW-F800- 4U (176 mm) 3.5 inch (LFF) DB60C Chapter 3: Drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Can be turned on or ■ turned off by the maintenance utility. Lock Locks and unlocks the front panel bezel by using the supplied key. Chapter 3: Drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Blue: IN side port is linked PATH (IN) connector Connects to a controller or drive tray. Console This port is reserved. ALARM LED Red: ENC can be replaced. Chapter 3: Drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Page 49
Indicates the location of ■ the chassis. Can be turned on or ■ turned off by the maintenance utility. POWER LED Green: ENC is in the power- on state. Chapter 3: Drive trays Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Green: Host port expansion is turned on. Amber: PCIe module is turned on. Off: PCIe module is turned off. Safety lock Lock or unlock the front bezel. PCIe switchboard Chapter 4: Host port expansion chassis Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Off: PCIe switchboard is powered off. Host port expansion chassis fan Number Item Description ALM LED Red: Fan failure has occurred. Off: Normal operation. Chapter 4: Host port expansion chassis Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Amber: Basic PCIe status changed from link up to link down and cables. Cables can be removed safely. Off: Basic PCIe is normal or not set. Chapter 4: Host port expansion chassis Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Host port expansion chassis power supply Number Item Description ALM / RDY LED Red: Host port expansion chassis power supply can be replaced safely. Green: Normal operation. Chapter 4: Host port expansion chassis Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Page 54
Host port expansion chassis power supply Number Item Description AC IN LED Blue: AC input is normal. Chapter 4: Host port expansion chassis Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
The NAS module provides communication ports to support file system protocols in a block- or file-system configuration. NAS Module Ports and LEDs Legend Name Color Description User LAN port This is used with the file level access. Chapter 5: NAS module Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Page 56
Reserved for future Status LED Green NAS modules are functioning normally. NAS modules can be removed. Link LED Blue Displays link status. Fail LED A failure has occurred. Chapter 5: NAS module Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
3. Verify the POWER LED on the front of the storage system changes from green to amber. 4. To stop the power supply, remove the power cables from the power supply units on the controller chassis and drive box. Chapter 6: Maintaining the storage system Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Observe the following instructions when removing cables form the storage system. To remove a SAS cable, pull the tab of the SAS cable (1) to release the latch and remove the SAS cable (2). Chapter 6: Maintaining the storage system Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Page 59
SAS cable (2). To remove a LAN cable, push the top of the LAN cable connector (1) to release the latch and remove the LAN cable (2). Chapter 6: Maintaining the storage system Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Appendix A: Mechanical specifications for VSP G400, G600 The storage system mechanical specifications are described for VSP G400, G600. VSP G400 and VSP G600 mechanical specifications Controller Quantity Component Description CBLM A 4U controller chassis consisting of controllers, channel boards, disk boards,...
Page 61
ENC and AC-DC power supplies equipped with built-in cooling fans. NAS module Component Description NAS module Component for block and file storage configuration Appendix A: Mechanical specifications for VSP G400, G600 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Page 65
Maximum volumes/host groups and iSCSI 2048 targets Maximum number of volumes per RAID 2048 group Shared memory and data assurance Appendix A: Mechanical specifications for VSP G400, G600 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Page 66
Dense intermix drive tray (DB60) 18.97 x 40.51 x 6.92 inches (482 x 1,029 x 176 mm) (includes the depth of the cable- management arms) Appendix A: Mechanical specifications for VSP G400, G600 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Steady-state power (VA/W) CBLM: 1600/1560 or less SFF drive tray: 480/460 or less LFF drive tray: 380/350 or less FMD drive tray: 520/490 or less Appendix B: Electrical specifications for VSP G400, G600 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Page 70
3. This table shows the power requirement (100 V or 200 V) for the maximum configuration . The actual required power might exceed the value shown in the table when the tolerance is included. Appendix B: Electrical specifications for VSP G400, G600 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Controller FMD drive trays Operating 50°F to 104°F DKC-F710I-1R6FM or DKC-F710I-3R2FM drive is (10°C to 40°C) installed: 50°F to 95°F (10°C to 35°C) Appendix C: Environmental specifications for VSP G400, G600 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Page 72
5.0 or less at 5 Hz to 300 Hz (no damage to product) 9.8 (1.0 G) Within 5 seconds (resonance point: 10 Hz or less) Transport (packed) 5.0 or less Appendix C: Environmental specifications for VSP G400, G600 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Page 73
900 (Environmental temperature: 10°C to 40°C) when 10°C to 32°C) DKC-F810I-1R6FN/3R2FN/6R4FN/7R0FP/14RFP drive is installed. (Environmental temperature: 10°C to 40°C) Non-operating -60 to 12,000 Appendix C: Environmental specifications for VSP G400, G600 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Page 74
32°C or less) (Environment temperature 32°C or less) temperature 32°C or less) Non- 55 dB 55 dB 71 dB (Environmental operat temperature 32°C or less) Appendix C: Environmental specifications for VSP G400, G600 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Page 75
3. Acoustic power level (LwA) measured by the ISO 7779 standard is 7.2 B. This value changes from 7.2 B to 8.1 B, according to the ambient temperature, drive configuration, and operating status. Appendix C: Environmental specifications for VSP G400, G600 Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Page 76
Hitachi storage systems are designed and manufactured for reliable operation when placed 2 meters from the source of the noise. Hitachi does not test storage systems and hard disk drives for compatibility with fire suppression systems and pneumatic sirens. Hitachi also does not provide recommendations or claim compatibility with any fire suppression systems and pneumatic sirens.
Page 80
255 per iSCSI port at one time CHAP Supported Authentication: login request is sent properly from host to storage. CHAP is not supported during discovery session. Appendix D: iSCSI standards and specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Page 81
Example: iqn.1994-04.jp.co.hitachi:rsd.d7m.t.10020.1b000.tar 4. eui: 64-bit Extended Unique Identifier. The eui consists of a type identifier, "eui," and an ASCII-coded, hexadecimal, EUI-64 identifier. Example: eui.0123456789abcdef Appendix D: iSCSI standards and specifications Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Replacement period The battery lifetime (intake temperature is 30 degrees C or less.) in the standard environment is as shown below. Appendix E: Replacement parts Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Serial-attached SCSI (SAS) cables are used to connect drive trays to controllers and other drive trays. Appendix F: Data and power cables Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Page 84
Cable size Speed Maximum cable length 9 micron 1 Gbps 1 km (3281 ft) 2 Gbps 2 km (6562 ft) 50 micron 2 Gbps 300 m Appendix F: Data and power cables Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Note: Due to high-speed serial data transfer via Fibre Channel, use high-quality FC cables that comply with the Fibre Channel-PH standard. The following figure shows FC direct connection and FC connection through a switch. Appendix F: Data and power cables Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Page 86
114.8 ft (35 m) 328.08 ft (100 410.1 ft (125 m) — 32 Gbps 65.62 ft (20 m) 229.7 ft (70 m) 328.08 ft (100 — Appendix F: Data and power cables Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Page 87
850 nm (OMx) LC-LC cable DXLC-2PS- 9/125 μm (longwave) SPC-xxM- Singlemode Wavelength: 10/125-2SR 1300 nm The following figure shows the connector used for optical interfaces. Appendix F: Data and power cables Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
One side Other side LC-LC cable Optical Equivalent to 50, 125 mm LC connector LC connector DXLC-2P- Multimode PC-xxM- Wavelength: GC50, 850 nm 125-2SR (OMx) Appendix F: Data and power cables Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Page 89
LC connector type ■ Connector type: LC duplex receptacle connector ■ Interval: 6.25 mm flat type, two rows ■ Cable specifications for 10 Gbps iSCSI copper interface Appendix F: Data and power cables Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Maximum transfer unit 1,500, 4,500, 9,000 bytes Jumbo frame, MTU size (MTU) (Ethernet frame) greater than 1500 Link aggregation Not supported Tagged VLAN Supported IPv4 Supported Appendix F: Data and power cables Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Page 92
IPv6 global address automatically. Subnet mask Supported Gateway address Supported DHCP Ping (ICMP ECHO) Supported Transmit, Receive IPsec Appendix F: Data and power cables Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Page 93
255 per iSCSI port at one time CHAP Supported Authentication: login request is sent properly from host to storage. CHAP is not supported during discovery session. Appendix F: Data and power cables Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
40 mm (1.73 inch) iSCSI optical 40 mm (1.73 inch) Category 5 Ethernet Four times the outside diameter of the cable 40 mm (1.73 inch) Appendix F: Data and power cables Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Page 95
When cabling full-width modules, such as NAS modules as shown in the following figure, route the cables horizontally, so that they do not interfere when replacing a module. Appendix F: Data and power cables Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Utility AC power standards for connector types and voltage levels vary by country. Hitachi provides a variety of power cables that facilitate using storage systems around the world. Hitachi power cables meet the safety standards for the country for which they are intended. Appendix F: Data and power cables...
Power cable assemblies Power cable assemblies For information about racks and power distribution units (PDUs), refer to the Hitachi Universal V2 Rack Reference Guide. Hitachi power cables consist of three parts: Plug: Male connector for insertion into the AC outlet providing power. The physical design ■...
8. 5-wire (three-phase, earth and neutral). Physical variations (connector size and color) indicate amperage rating. AC connections The following table shows and describes the types of AC connections on your storage system. Appendix F: Data and power cables Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Page 99
CEE 7/7 200V-240V 4 CEE (7) II, IV, VII 3 IEC 83 BS-1363 200V-240V 5 BS 1365 3 IEC 83 AS-3112 200V-240V 6 AS C112 Appendix F: Data and power cables Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Cable and connector Power cable usage guidelines Hitachi storage systems are intended for rack installation and ship with power cords. Installation and service requirements may require additional cords and cables to be ordered. The type of power cable required by a given installation is determined primarily by the: Type of AC line feed provided by the facility.
Cable management Rack installations should be planned for operational efficiency, ease of maintenance, and safety. Hitachi offers the Backend Configuration Utility (BECK), a graphical, cable- management application that can relieve the typical cable congestion created when populating a rack with storage systems and their accessories.
The following addresses are available for setting Fibre Channel ports. Loop ID Loop ID Loop ID Loop ID Loop ID AL-PA (0~29) AL-PA (30~59 AL-PA (60~89) AL-PA (90~119) AL-PA (120~125) Appendix G: Port address mapping Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Page 103
Port address mapping Loop ID Loop ID Loop ID Loop ID Loop ID AL-PA (0~29) AL-PA (30~59 AL-PA (60~89) AL-PA (90~119) AL-PA (120~125) Appendix G: Port address mapping Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
PDUs and cable loops. Hitachi Universal V2 Rack rail kits Use rail kits to mount the Hitachi Virtual Storage Platform family storage system in a Hitachi Universal V2 Rack. The following tables list the rail kit information for the specified storage systems.
Appendix I: Regulatory compliance This equipment has been tested and certified for compliance with the following standards. Appendix I: Regulatory compliance Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Page 108
EN60950-1:2006+A1 TUV Germany IEC60950-1:2005+A All CB countries IEC60950-1:2005+A S-Mark Argentina TP TC 004/2011 Russia CNS 14336-1 BSMI Taiwan EN60950-1:2006+A1 CE Radio interference VCCI V-3/2013.04 VCCI Japan voluntary control Appendix I: Regulatory compliance Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
They will dispose of it for you. This nickel-metal hydride battery, which is designated as recycling product by a recycling promotion low, must be recycled. The mark posted on the Cache Backup Battery is a three-arrow mark that indicates a recyclable part. Appendix J: Environmental notices Hitachi Virtual Storage Platform G400, G600 Hardware Reference Guide...
Page 110
Hitachi Vantara Corporate Headquarters Contact Information 2535 Augustine Drive USA: 1-800-446-0744 Santa Clara, CA 95054 USA Global: 1-858-547-4526 HitachiVantara.com | community.HitachiVantara.com HitachiVantara.com/contact...
Need help?
Do you have a question about the G400 and is the answer not in the manual?
Questions and answers