Summary of Contents for HP StorageWorks XP20000/XP24000 - Disk Array
Page 1
HP StorageWorks XP24000/XP20000 SNMP Agent Reference Guide Abstract This guide describes the implementation of Simple Network Management Protocol (SNMP) for monitoring HP StorageWorks XP24000/XP20000 storage systems. The guide lists the monitored storage system components and supported traps, describes the trap protocol and extension MIB, and explains how to use the GUI to limit SNMP access to specific SNMP managers.
Page 5
Figures SNMP Environment ....................7 SNMP Environment Architecture .................. 9 Example of SNMP Operations ..................9 SNMP Information Tab .................... 14 Adding SNMP Manager IP Address (Top: Before Setting, Bottom: After Setting) ....18 Delete IP Address Menu ................... 19 Add Community Menu ....................
Page 6
Tables SNMP Trap Triggering Events ..................9 SNMP Agent Operations ..................10 SNMP Agent REQUEST Operations ................10 Available Component Status Information ..............11 Storage system Component Status Types ..............11 SNMP Information Tab .................... 14 Extension Trap Specifications ................... 25 Specific Trap Codes ....................
1 Overview of SNMP This chapter provides an overview of SNMP including an overview of the agent and management functions: SNMP Manager Overview SNMP Agent Overview SNMP Manager Functions Unless otherwise specified, the term storage system in this guide refers to the following disk arrays: HP StorageWorks XP24000 Disk Array HP StorageWorks XP20000 Disk Array The GUI illustrations in this guide were created using a Windows computer with the Internet Explorer...
An SNMP manager monitors the devices, which are referred to as managed nodes. The primary types of interaction between the SNMP manager and an SNMP agent are polling and trap. Typically, the SNMP manager polls the SNMP agents on a periodic basis, to determine whether the device is operating normally.
Figure 2 SNMP Environment Architecture The following figure shows an example of SNMP operations by using an SNMP manager. Figure 3 Example of SNMP Operations SNMP Agent Functions SNMP Traps An SNMP agent reports a storage system error to a SNMP manager using the trap report function. If an error occurs, an SNMP agent issues an SNMP trap to an SNMP manager to report a failure.
Events Description Service failure detected. Minor failure. An SNMP agent logs the most recent 256 traps, so you can see the trap history of a particular device. SNMP Agent Operations The following table lists the types SNMP Agent operations. Table 2 SNMP Agent Operations Operation Description Obtains a specific MIB object value.
SNMP Manager Functions Component Status Information You can obtain the status information for certain storage system components from an SNMP manager. The following table lists the components for which the status can be obtained. Table 4 Available Component Status Information Area Component Name Processor...
2 Using the SNMP GUI This chapter explains the SNMP information tab: SNMP Information Tab SNMP Information Tab The SNMP IP Security tab allows you to limit SNMP access to specific SNMP managers and to enter SNMP trap addresses. Click Go – Install – SNMP SNMP IP Security in the menu bar of Remote Web Console Main window.
Figure 4 SNMP Information Tab Table 6 SNMP Information Tab Item Description The Extension SNMP check box is selected if the SNMP Agent feature is enabled. Install To set the SNMP Agent properties from XP Remote Web Console computer, select Extension SNMP on SNMP Information window.
Page 15
Item Description Enter the IP address of the manager that the SNMP Agent receives the request from. Ipv4 and Ipv6 addresses can be specified for IP Address. However, if the OS of SVP is Windows XP and you enter Ipv6 address and select Apply, an error message is displayed and the Ipv6 address is not set.
Page 16
Item Description Allows you to add, delete or change SNMP system group information. If system group information has already been registered, the registered information displays. To register the system group information, the Extension SNMP check box must be selected. When you register system group information, select Apply.
3 Performing SNMP Operations This chapter covers adding and deleting an SNMP manager IP address, adding and deleting a community name, along with adding and deleting a community IP address: Adding SNMP Manager IP Addresses Deleting SNMP Manager IP Addresses Adding a Community Name Deleting a Community Name Changing a Community Name...
Select Apply to implement the changes, or select Cancel to cancel the changes, then select OK on the confirmation message. Figure 5 Adding SNMP Manager IP Address (Top: Before Setting, Bottom: After Setting) Deleting SNMP Manager IP Addresses To delete an SNMP Manager IP address: Change to Modify mode.
Figure 6 Delete IP Address Menu Adding a Community Name To add a community name: Change to Modify mode. Log on to Remote Web Console. Click Go Environmental Settings SNMP Information in the menu bar of Remote Web Console Main window. The SNMP Information window is displayed (see Figure 4 on page 14).
Figure 7 Add Community Menu Figure 8 Add Community dialog box Deleting a Community Name To delete a community name: Change to Modify mode. Log on to open Remote Web Console Main window, click Go Environmental Settings SNMP Information in the menu bar of Remote Web Console Main window. The SNMP Information window is displayed (see Figure 4 on page 14).
Figure 9 Delete Community Menu Changing a Community Name To change a community name: Change to Modify mode (see HP StorageWorks XP24000/XP20000 Remote Web Console User's Guide if you need instructions). Log on to Remote Web Console. Click Go Environmental Settings SNMP Information in the menu bar of Remote Web Console Main window.
Figure 10 Change Community Menu Figure 11 Change Community dialog box Adding Community IP Addresses To add a community IP address: Log on to Remote Web Console. Click Go Environmental Settings SNMP Information in the menu bar of Remote Web Console Main window. The SNMP Information window is displayed (see Figure 4 on page 14).
In IP Address, enter a new IP address or select an existing IP address. NOTE: If the values for an IP address are all set to zero (0), that address cannot be specified for Ipv4 and Ipv6. The Add IP Address dialog box does not support shortened expression for Ipv6 address. Enter 8 hexadecimal numbers that are separated colons (:) to a maximum 4 digits from zero (0) to FFFF inclusive.
Change to Modify mode. Log on to Remote Web Console. Click Go Environmental Settings SNMP Information in the menu bar of Remote Web Console Main window. The SNMP Information window is displayed (see Figure 4 on page 14). Select SNMP Information. In Community &...
4 SNMP Supported MIB This chapter explains MIB specifications, standard and extension, the SNMP GUI, and trap configuration: Trap Configuration Standard MIB Specifications Extension MIB Specifications Extension MIB Configuration Trap Configuration Extension Trap Specifications The specifications of the supported extension trap are as follows. Table 7 Extension Trap Specifications Operation Specification...
Extension Trap Protocol Data Unit (PDU) Failure Report Trap An extension trap protocol data unit (PDU) includes the product number of the device that experienced the failure, the device nickname, and a failure reference code. If you obtain the information with GetRequest command, access the MIB by using the product number of the device as an index.
Supported? at group Not supported ip group Not supported icmp group Not supported tcp group Not supported udp group Not supported egp group Not supported snmp group Not supported Extension MIB Supported MIB Access Mode The access mode for MIB in all communities is read only. If you send a GET request for a SET operation, you will receive NoSuchName as a GET RESPONSE.
Figure 16 Object System (2) Figure 17 Object System (3) Supported Traps The following table shows the supported trap types. Table 11 Extension Trap Types Specific Trap Trap Description Code RaidEventUserAcute All operations in a storage system stopped. Operation in a component where a failure RaidEventUserSerious occurred stopped.
Specific Trap Trap Description Code RaidEventUserService Minor failure. MIB Mounting Specifications The supported MIB mounting specifications are as follows: mgmt: OBJECT IDENTIFIER ::= {iso(1) org(3) dod(6) internet(1) 2 } mib-2: OBJECT IDENTIFIER ::= {mgmt 1} An SNMP agent mounts only system groups in mib-2, as shown in the following table. Table 12 System Groups Name Description...
Number of Storage Systems under Control of SVP (raidExMibDkcCount) raidExMibDkcCount suggests the number of a storage system under the control of SVP. raidExMibRaidList raidExMibRaidList indicates the storage system under the control of the SVP. (raidlistEntry) raidlistEntry indicates the list of arrays managed by this SVP The following table shows the type of information displayed for each storage system Table 13 Storage system Information Name...
Name Type Description Mounted Value Attribute raidlistMibNickName (Max. 18 DisplayString Storage system nickname. read-only characters) ::=raidlistEntry(2) raidlistDKCMainVersion (Max. 10 DisplayString Microcode version. read-only characters) ::=raidlistEntry(3) raidlistDKCProductName Storage system product DisplayString read-only type. ::=raidlistEntry(4) (7 characters) *1 RAID600 will be indicated as Storage system product type (raidlistDKCProductName). raidExMibDKCHW raidExMibDKCHW indicates the status of the storage system components.
Name Type Description MIB Value Attribute DKCHWCache Note INTEGER Status of cache. read-only ::=dkcHWEntry(4) (1 digit) Note DKCHWSM Status of shared INTEGER read-only memory. ::=dkcHWEntry(5) (1 digit) DKCHWPS Note INTEGER Status of power supply. read-only ::=dkcHWEntry(6) (1 digit) DKCHWBattery Note INTEGER Status of battery.
Table 15 Storage System components information Name Type Description MIB Value Attribute DKURaidListIndexSerialNumber Storage system product INTEGER 1-99,999 read-only number (index). ::=dkuHWEntry(1) DKUHWPS Note INTEGER Status of power supply. read-only ::=dkuHWEntry(2) (1 digit) Note DKUHWFan INTEGER Status of fan. read-only ::=dkuHWEntry(3) (1 digit) DKUHWEnvironment...
Table 16 Storage system components information 2 Name Type Description MIB Value Attribute DKC2RaidListIndexSerialNumber Storage system product INTEGER 1-99,999 read-only number (index). ::=dkcHW2Entry(1) DKCHW2Environment Note Information about INTEGER read-only environmental failure. ::=dkcHW2Entry(2) (1 digit) DKCHW2SVP Note INTEGER Status of SVP. read-only ::=dkcHW2Entry(3) (1 digit)
Table 17 Failure Information Name Type Description MIB Value Attribute EventListIndexSerialNumber Storage system product INTEGER 1-99,999 read-only number (index). ::=eventTrapEntry(1) EventListNickname Storage system (Max. 18 DisplayString read-only nickname. characters) ::=eventTrapEntry(2) EventListIndexRecordNo Counter Number of record. 1-256 read-only ::=eventTrapEntry(3) EventListREFCODE DisplayString Reference code.
5 SNMP Failure Trap Reference This chapter shows the alert level, the trap reference code, the description, and the alert level: Table 18 Table 19 The following table shows the alert level, the trap reference code, the description, and the alert level. Table 18 SNMP Failure Trap Reference Codes Trap Reference Code Description...
Page 42
Trap Reference Code Description Alert Level SIM22 SIM23 SIM13 Ethernet error for SVP MODERATE Failure during SIM transfer to SVP SERIOUS Audit log disappeared MODERATE Inaccessible audit log Drive failure MODERATE Environmental fail- Fuse failure MODERATE Fuse failure MODERATE Abnormal temperature MODERATE Power supply Alarm for voltage...
Page 43
Trap Reference Code Description Alert Level SIM22 SIM23 SIM13 Warning caused by remaining a jumper DKC environment MODERATE socket Error in two-SVP configuration SVP error MODERATE Power supply AC-DC alarm MODERATE (DKU) 56V Low voltage MODERATE HDD-PL 37V Low voltage MODERATE Abnormal fan MODERATE...
Page 44
Trap Reference Code Description Alert Level SIM22 SIM23 SIM13 Waiting for periodic copying SERVICE Periodic copying finished SERVICE Update I/O received after periodic Failure with paired SERVICE copying finished volumes Status change according to the PPRC pair status change assignment from SERVICE (Simplex->Duplex Pend) Status change according to the PPRC...
Page 45
Trap Reference Code Description Alert Level SIM22 SIM23 SIM13 Status change according to the PPRC pair status change assignment from SERVICE (Duplex Pend -> Suspend [Continue]) Status change according to the PPRC pair status change assignment from SERVICE (Duplex Pend -> Suspend [Complete]) Status change according to the PPRC pair status change assignment from SERVICE...
Page 46
Trap Reference Code Description Alert Level SIM22 SIM23 SIM13 ACUTE/SERIOUS level SIM reported SERIOUS from RCU Suspicion of the pair status failure SERIOUS Initial copy operation or update copy operation for Hitachi TrueCopy™ for Mainframe volume has started SERVICE x: The CU number yy: The LDEV number Initial copy operation for TrueCopy for Mainframe volume has finished...
Page 47
Trap Reference Code Description Alert Level SIM22 SIM23 SIM13 MCU requested R-VOL to change status. Failure with paired x: The CU number SERVICE volumes yy: The LDEV number A currently used M-VOL has been suspended because an unrecoverable failure occurred in the remote copy Failure with paired SERIOUS connection.
Page 48
Trap Reference Code Description Alert Level SIM22 SIM23 SIM13 A currently used R-VOL has been suspended because an unrecoverable failure occurred in R-VOL. SERIOUS x: The CU number yy: The LDEV number MCU detected a service-level SIM of RCU. SERVICE x: The CU number yy: The LDEV number MCU detected a moderate-level SIM of...
Page 49
Trap Reference Code Description Alert Level SIM22 SIM23 SIM13 Volume used as a P-VOL of Delta resync has been suspended SERIOUS x: The CU number yy: The LDEV number Volume in the main storage system has been suspended because failure suspend SERIOUS occurs in the remote storage system.
Trap Reference Code Description Alert Level SIM22 SIM23 SIM13 XP Thin Exceeded the pool usage threshold1. MODERATE Provisioning Pool Exceeded the pool usage threshold2. MODERATE Pool became full. MODERATE Pool detected a failure. MODERATE No free area in SM. MODERATE The pool usage threshold is being ex- MODERATE ceeded.
6 Troubleshooting This chapter provides troubleshooting information for the HP StorageWorks XP24000/XP20000 SNMP Agent Reference Guide: Mitigating SNMP Errors Calling HP Technical Support Mitigating SNMP Errors Use setup.exe when you install a secondary SVP. If you do not, traps could be reported to an IP address that is not specified in SNMP settings.
7 Support and Other Resources Related Documentation HP StorageWorks XP RAID Manager User's Guide HP StorageWorks XP24000/XP20000 LUN Manager User's Guide HP StorageWorks XP24000 Disk Array Owner's Guide HP StorageWorks XP20000 Disk Array Owner's Guide HP StorageWorks XP24000/XP20000 Remote Web Console User's Guide HP StorageWorks XP10000 Disk Array Owner's Guide HP StorageWorks XP12000 Disk Array Owner's Guide HP StorageWorks XP12000/XP10000 Remote Web Console User's Guide...
http://www.hp.com/support Before contacting HP, collect the following information: Product model names and numbers Technical support registration number (if applicable) Product serial numbers Error messages Operating system type and revision level Detailed questions Subscription Service HP recommends that you register your product at the Subscriber’s Choice for Business website: http://www.hp.com/go/e-updates After registering, you will receive email notification of product enhancements, new driver versions, firmware updates, and other product resources.
A Acronyms and Abbreviations Table 20 Acronyms and Abbreviations control unit (logical control unit) DASD direct-access storage device disk adapter disk controller local area network LDEV logical device main control unit M-VOL main volume (TrueCopy for Mainframe primary volume) remote control unit R-SIM remote service information message R-VOL...
Index related documentation, adding SNMP community IP address, SNMP community name, SNMP managers, SNMP Agent operations adding SNMP community IP address, adding SNMP community name, adding SNMP managers, changing changing SNMP community name, SNMP community name, deleting SNMP community IP address, conventions deleting SNMP community name, storage capacity values,...
Need help?
Do you have a question about the StorageWorks XP20000/XP24000 - Disk Array and is the answer not in the manual?
Questions and answers