Table of Contents Contents 1.Introduction-------------------------------------------------------------------------------------------------------------------1 2.List of fuctions---------------------------------------------------------------------------------------------------------------6 3.Specifications ----------------------------------------------------------------------------------------------------------------7 4.Printed Circuit Board Connector Wiring Diagram -----------------------------------------------------------------9 5.Funcitions and Control---------------------------------------------------------------------------------------------------14 5.1 Main functions and control specification of indoor unit - --------------------------------------------------------14 -----------------------------------------------------------------------------------22 The control system of outdoor unit Value of termistor ------------------- -----------------------------------------------------------------------------------22 6.
Introduction 1. Introduction 1.1 Safety Cautions Be sure to read the following safety cautions before conducting repair work. The caution items are classified into “Warning” and “Caution”. The “Warning” items are especially important since they can lead to death or serious injury if they are not followed closely. The “Caution” items can also lead to serious accidents under some conditions if they are not followed.
Introduction Warning Do not repair the electrical components with wet hands. Working on the equipment with wet hands can cause an electrical shock. Do not clean the air conditioner by splashing water. Washing the unit with water can cause an electrical shock.
Page 5
Introduction Warning Be sure to use an exclusive power circuit for the equipment, and follow the technical standards related to the electrical equipment, the internal wiring regulations and the instruction manual for installation when conducting electrical work. Insufficient power circuit capacity and improper electrical work can cause an electrical shock or fire. Be sure to use the specified cable to connect between the indoor and outdoor units.
Introduction Caution Installation of a leakage breaker is necessary in some cases depending on the conditions of the installation site, to prevent electrical shocks. Do not install the equipment in a place where there is a possibility of combustible gas leaks. If a combustible gas leaks and remains around the unit, it can cause a fire.
Page 7
Introduction Caution Check to see if the parts and wires are mounted and connected properly, and if the connections at the soldered or crimped terminals are secure. Improper installation and connections can cause excessive heat generation, fire or an electrical shock. If the installation platform or frame has corroded, replace it.
2 List of fuctions Functions Category Child lock Avoid the child's wrong operation on the remote controller The 3D airflow is able to deliver the airflow horizontally and vertically. 3D air flow 24Hour timer Use the timer function to set on,or off,or from on to off,or from off to on Automatic return to previous operation conditions after sudden power blackout Auto restart Easy clean...
3 Specifications H S U 1 0 9 V H G -G H S U 2 1 8 V H G -W M o d e l 9 + 9 C o o lin g H e a tin g 4 .8 5 .5 C a p a c ity R a te d (M in .-M a x .)
Page 10
H S U 2 1 8 V H G -W O u td o o r U n it 9 + 9 C a s in g C o lo r W h ite T yp e ro ta ry C o m p re s s o r C o m p re s s o r M o d e l S N B 1 3 0 F G Y M 2...
Connector wring diagram 4.Printed Circuit Board Connector Wiring Diagram indoor unit Connectors PCB(1) (Control PCB) 1) CN9 CN27 Connector for fan motor and feedback 2) CN1 Connector for heat exchanger thermistor and Room temperature thermistor 3) CN11 Connector for UP&DOWN STEP motor 4) CON2 Connector for power N wire 5) CON1 Connector for power L 6) CN30 CN31 Connector transformer...
Connector wiring diagram Outdoor unit Connectors PCB(1) (Control PCB) 1) CN1,CN2 Connector for power N and L 2) CN3 Connector for ground 3) CN23 Connector for DC POWER 15Vand 5V to the module board 4) CN9,CN10 Connector for CN2,CN1 on the module board 5) CN22 Connector for fan motor 6) CN11 Connector for four way valve coil 7) CN17,CN18,CN19,CN20,CN21 Connector for thermistors...
Functions and control 5.Funcitions and Control 5.1 Main functions and control specification 5.1.1 Automatic operation When the running mode is turned to automation after starting the system, the system will first determine the running mode according to the current room temperature and then will run according to the determined mode.
Functions and control 5.1.3 Dehumidifying mode. * temperature control range: 16---30 * temperature difference: Control feature: send the dehumidifying signal to the outdoor system. When Tr>Ts+2 , the compressor will be turned on, the indoor fan will operate at the set speed. When Tr is between the Ts and Ts+2 , the outdoor system will operate at the high dehumidifying frequency for 10 minutes and then at the low dehumidifying mode for six minutes.
Page 18
Functions and control *Indoor fan control manual control: You can choose high, medium, low and automatic speed control. Automatic: When Tr<Ts, high speed. When Ts≤Tr≤Ts+2 , medium speed. When Tr> Ts+2 , low speed. When the airflow speed has no delay from the high to low switching, the speed should be delayed for 3 minutes (remain at high speed for 3 minutes.) before the next switch.
Page 19
Functions and control When the system is at the automatic option with the strength/ mute function, if the system enters the cooling mode, the cooling strength/ mute function will be offered; if the system enters the heating mode, then the heating strength/ mute function will be offered; if the system enters the airflow mode, there will be no strength/ mute function.
Page 20
Functions and control operations, the set temperature will be raised for 1 centigrade and the system will keep this status for 3 hours and then close down. 2.3 During the dormant time, except the change of the system mode or a new press on the dormant setting keys, the timing of the 8 hours dormancy will take the first timing as the start time, any presses on other keys will not affect the original timing.
Page 21
Functions and control The outdoor system will be stopped if the coil temperature is above 65 for 2 minutes. The indoor fan will be controlled by the thermostat. The outdoor system can be restarted when the coil temperature is below 42 and the system has been stopped for 3 minutes.
Page 22
Functions and control 5.1.16 Single indoor system operation * Enter condition: First, set the high speed airflow and 30 centigrade set temperature, then press the dormant keys for 6 times within 7 seconds, the system will feedback with 6 rings. * After the system enters the separate indoor system operation mode, the indoor system will operate according to the set mode and neglect the communication signals of the outdoor system.
Page 23
Functions and control First, connect the test program terminal on the mainboard. Then connect the system to the power circuit. The test program will operate as follows. HV series display: The buzzer rings for one time—the signal will be sent to outdoor system for 0.5 second—...
Functions and control 5.2 The control system of outdoor unit 5 2.1 The operation frequency of outdoor unit and its control 5.2.1.1 The operation frequency control of compressor The operation frequency scope of compressor Mode Minimun operation frequency Maximun operation frequency 5.2.1.2 The starting of compressor When the compressor is started for the first time, it must be kept under the conditions of 58Hz,88Hz for one minute (the overheating protection of the outdoor unit air-blowing temperature,...
Page 25
Functions and control Serial Temperature scope Frequency limitation Wh_c<-12 Max_hz8 120 HZ Wh_c<-8 Max_hz7 120HZ Wh_c<-2 Max_h z4 120 HZ Wh_c<5 Max_hz5 120HZ Wh_c<12 Max_hz1 100HZ Wh_c<18 Max_hz2 56 HZ Wh_c> 18 Max_hz6 44 HZ Remarks: the above are the maximum frequency limitations of the complete appliance which are affected by the environment, and they have nothing to do with the ability of the indoor unit.
Functions and control The calculation of the actual output frequency: when there is no healthy airflow: F =F-ED-* P K When the healthy airflow has been set: F =F-ED-* P K airflow speed K healthy airflow When refrigerating, it is needed to satisfy <...
Functions and control When the outdoor unit is shut down, the valve is opened completely for 2 minutes, and then begin initialization. The scope of refrigerationg valve 90-----480 steps The scope of heating valve 80-----480 steps The valves are adjusted according to the degree of superheat SHa.
Page 28
Functions and control The compressor stops Fgh_t1 2 Fgh_t1 65 Decreasing the frequency rapidly Fgh_t2 Fgh_t2 2 P Decreasing the frequency slowly Fgh_t3 Fgh_t3 2 Q Prohibiting increasing the frequency Fgh_t4 Fgh_t4 2 R Increasing slowly Fgh_t5 Fgh_t5 2 Normal N Decreasing at the speed of 1HZ/1 second P Decreasing at the speed of 1Hz/10...
Page 29
Functions and control When the outdoor environment temperature is higher than 50 ,AC current protection value decreases by 20AD 5.2.5.5 Antifreezing protection of the indoor heat exchanger When refrigerating/heating, prevent freezing. Tpg_indoor is the minimum value of the effective indoor unit (start it and it is in accord with the running state).
Page 30
Functions and control light shoud be off for 5 seconds. b) For the units’ malfunctins Annex 1 If there’s malfunction with the units, this will not affect the run of the complete appliance, but this can be displayed by the malfunction light, the light flashing frequency is 0.5HZ, the number of times is according to the malfunction table of the indoor units.
Service diagnosis 6. Service Diagnosis 6.1 Caution for Diagnosis The operation lamp flashes when any of the following errors is detected. 1. When a protection device of the indoor or outdoor unit is activated or when the thermistor malfunctions, disabling equipment operation. 2.
Service diagnosis 6.3.1 Thermistor or Related Abnormality Indoor Display E1: Room temperature sensor failure E2: Heat-exchange sensor failure Outdoor display LED1 flash 10 times Defrost temperature sensor failure LED1 flash 11 times Suction temperature sensor failure LED1 flash 12 times Ambient temperature sensor failure LED1 flash 13 times Discharge temperature sensor failure Method of The temperatures detected by the thermistors are used to determine thermistor errors...
Service diagnosis 6.3.2 EEPROM abnormal Indoor Display E4: Indoor EEPROM error Indoor display F12: Outdoor EEPROM error; Outdoor LED1 flash 1 times Method of The Data detected by the EEPROM are used to determine MCU Malfunction Detection Malfunction When the data of EEPROM is error or the EEPROM is damaged Decision Conditions Supposed...
Service diagnosis 6.3.3 Indoor AC fan motor malfunction Indoor Display Method of The rotation speed detected by the Hall IC during fan motor operation is used to determine Malfunction abnormal fan motor operation Detection Malfunction when the detected rotation feedback signal don’t received in 2 minutes Decision Conditions Supposed...
Service diagnosis 6.3.4 Outdoor DC fan motor fault Outdoor display LED1 flash 9 times Method of DC fan motor is detected by checking the fan running condition and so on Malfunction Detection Malfunction when the data of EEPROM is error or the EEPROM is damaged Decision Conditions Supposed...
Service diagnosis 6.3.5 IPM protection Outdoor display: LED1 flash 2 times Method of IPM protection is detected by checking the compressor running condition and so on Malfunction Detection Malfunction ■ The system leads to IPM protection due to over current Decision ■...
Service diagnosis 6.3.6 Over-current of the compressor Outdoor Display: LED1 flash 3 or 24 or 25 times Method of The current of the compressor is too high Malfunction Detection Malfunction when the IPM Module is damaged Decision or the compressor is damaged. Conditions power supply voltage is too low or too high Supposed...
Service diagnosis 6.3.7 The communication fault between IPM and outdoor PCB Outdoor display: LED1 flash 4 times Method of Communication is detected by checking the IPM module and the outdoor PCB Malfunction Detection Malfunction ■ The outdoor PCB broken leads to communication fault Decision ■...
Service diagnosis 6.3.8 Power Supply Over or under voltage fault Outdoor display: LED1 flash 6 times The power supply is over voltage Method of An abnormal voltage rise or fall is detected by checking the specified voltage detection circuit. Malfunction Detection Malfunction An voltage signal is fed from the voltage detection circuit to the microcomputer...
Service diagnosis 6.3.9 Overheat Protection For Discharge Temperature Outdoor display: LED1 flash 8 times Method of The Discharge temperature control is checked with the temperature being detected Malfunction by the Discharge pipe thermistor Detection Malfunction when the compressor discharge temperature is above 110 Decision Conditions Supposed...
Service diagnosis 6.3.10 The communication fault between indoor and outdoor Indoor display outdoor display LED1 flash 15 times Method of Communication is detected by checking the indoor PCB and the outdoor PCB. Malfunction Detection Malfunction ■ The outdoor PCB broken leads to communication fault. Decision ■...
Page 55
Service diagnosis Check the indoor mainboard. Measure the voltage between Jumpers 3 and 4 of IC1 on the indoor mainboard with a multimeter. Test the outdoor power supply (230VAC and +310VDC) with a multimeter. If the voltage is of a constant value of 0V DCto5V DC If 230VAC is available but 310DC not, the power module is damaged, replace it...
Service diagnosis 6.3.11 Loss of synchronism detection Inverter side current detection is abnormal Outdoor Display LED1 flash 18 times LED1 flash 19 times Method of The position of the compressor rotor can not detected normally Malfunction Detection Malfunction when the wiring of compressor is wrong or the connection is poor; Decision or the compressor is damaged Conditions...
Service diagnosis 6.3.12 High work-intense protection Outdoor display LED1 flash 21 times Method of High work-intense control is activated in the heating mode if the temperature Malfunction being sensed by the heat exchanger thermistor exceeds the limit. Detection Malfunction Activated when the temperature being sensed by the heat exchanger Decision rises above 65 twices in 30 minutes.
Exponent 7.Exponent Parts and Functions Remote Control Indoor Unit 9. QUIET button 10. HEAT button Air Purifying Filter Inlet 11. COOL button (inside) 12. AUTO button 13. FAN button 14. TIMER button Front Cover 15. HEALTH button 16. LOCK button Used to lock buttons and LCD display.
Exponent Operation Basic Operation Emergency Operation and Test Operation Emergency Operation: Use this operation only when the remote controller is defective or lost, and with function of emergency running, air conditoner Remote controller can run automatically in few seconds. When the emergency operation switch is pressed, the unit beeps once, which starts the operation.
Exponent Operation Sleep Operation In AUTO mode If the unit is running cooling, the sleep mode will follow Press button to enter additional options, cycle the function as in cool mode, while follow as in heat mode. the display to will flash.
Exponent Operation Timer On/Off On-Off Operation Healthy Airflow Operation 1.After unit starts, select your desired operation mode. 1.Press to start Setting for comfortable conditions. 2.Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: 2.The setting of healthy airflow function Remote controller: button to enter additional options,Press this...
Exponent Maintenance For Smart Use of The Air Conditioner Remote Controller Indoor Body Setting of proper room Do not block the air inlet temperature or outlet Proper wipe the air conditioner by using a temperature soft and dry cloth.For serious stains, use a neutral detergent diluted with Do not usewater,wipe the controller water.Wring the water out of the...
Page 63
Exponent Cautions WARNING Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage. WARNING Check proper When abnormality such as burnt-small found, Use an exclusive immediately stop the operation button and power source installation of the...
Exponent Trouble shooting Cautions Before asking for service, check the following grille of the air Do not obstruct or cover the ventilation first. conditoner.Do not put fingers or any other things into the inlet/outlet and swing louver. Do not allow children to play with the air conditioner .In no Phenomenon Cause or check points...
Installation 8.Installation Indoor Unit Installaion Necessary Tools for Installation Power Source Torque wrench Driver Before inserting power into receptacle, check the voltage without (17mm,22mm,26mm) Nipper fail. Pipe cutter Hacksaw The power supply is the same as the corresponding nameplate. Flaring tool Hole core drill Install an exclusive branch circuit of the power.
Installation Indoor Unit Installation [ Left Left-rear piping ] Fitting of the Mounting Plate and Positioning of the wall Hole In case of left side piping, cut away, with a nipper, the lid for left piping. In case of left-rear piping, bend the pipes according to the piping When the mounting plate is first fixed direction to the mark of hole for left-rear piping which is marked on heat insulation materials.
Page 67
F aulty P C B ; Model HSU18VHG(DB)-G sensor failure HSU24VHG(DB)-G HSU109VHG-G F aulty E E P R O M data; Indoor E E P R O M F aulty E E P R O M ; 4G0.75mm Connecting wiring error F aulty P C B ;...
Page 68
Installation Installation Manual of Room Air Conditioner Preparation Necessary Tools for Installation Selection of Installation Place Indoor Unit - Select a location that is Torque wrench Hammer (17mm,22mm,26mm) Nipper Robust not causing vibration, where the unit can be supported satisfactorily. Pipe cutter Hacksaw Not affected by heat or steam generated in the vicinity, and where the inlet and outlet of...
Installation Accessory parts Making a Hole on the Wall and Fitting the Piping Hole Cover Drain hose (1) Remote controller (1) Make a hole of B mm / inches in diameter, slightly descending to outside the wall. Install piping hole cover and seal it off with putty after installation Cushion (4) AAA dry battery (2) Pitch downward for drainage...
Installation Outdoor unit Connecting the indoor/outdoor electric Cable Installation of Outdoor Unit Removing the wiring cover Install according to the instructions on the 1st page of this manual Remove terminal cover at right bottom corner of indoor unit, then take off wiring cover by removing its screws.
Page 71
Installation Power Source Installation Connection Loosen the screws on terminal block and insert the wires fully into terminal The power source must be exclusively used for air conditioner. block, then tighten the screws. In the case of installing an air conditioner in a moist place, please install an ea- rth leakage breaker.(GFCI) If wiring is not correct, the unit will not operate properly and it could cause a For installation in other places, use an HVACR circuit breaker or time delay fuse.
Page 72
Installation Outdoor Unit When the The wiring of compressor is wrong or Suction temperature sensor failure the connection is poor Check if there is leakage in the unit. Lack of refrigerant...
Page 74
Removal of procedure Please embed the air filters into the unit along the grooves as installation. P l ease embed the two hooks on air filter com pletely into the unit during installat ion . Domestic air conditioner...
Page 75
Removal of procedure Remocal of front panel until it is on the horizontal position, and then release the pivots on both sides of the unit to remove the front panel. Please close the panels before start the removal procedure of front grille. one side to another to release each axis.
Page 76
Removal of procedure HOOKS three Domestic air conditioner...
Page 77
Removal of procedure horizontal flap flap flap flap flap Domestic air conditioner...
Page 78
Removal of procedure Remove the swing Moter Remove the vertical blades Every blade go round and round,then move Domestic air conditioner...
Page 79
Removal of procedure Domestic air conditioner...
Page 80
Removal of procedure Domestic air conditioner...
Page 81
Removal of procedure Domestic air conditioner...
Page 82
Removal of procedure Domestic air conditioner...
Removal of procedure Outdoor Unit Removal of Outdoor Panel Domestic air conditioner...
Page 84
Removal of procedure Loosen the top panel screws Lift the top panel Domestic air conditioner...
Page 85
Removal of procedure Loosen the csrews and pull the panel Domestic air conditione...
Page 86
Removal of procedure 2 Pull the wind circle Remove the inlet grill Push the hooks first Domestic air conditioner...
Page 87
Removal of procedure Domestic air conditioner...
Page 88
Removal of procedure Domestic air conditioner...
Page 89
Removal of procedure Loosen the fixing screws and remove the motor Domestic air conditioner...
Page 90
Removal of procedure Domestic air conditioner...
Page 91
Removal of procedure Loosen the screw and remove the reactor Domestic air conditioner...
Page 92
Removal of procedure Loosen the marked screws and pull out the backgurd Domestic air conditioner...
Page 93
Removal of procedure Loosen the marked screws and remove the stop valves Loosen the marked screws and remove the stop valves bracket Domestic air conditioner...
Page 96
Wring diagram 2 2 0 V _ L G N D Domestic Air Conditioner...
Page 97
Wring diagram Remarks DON'T TOUCH CAPACITOR, EVEN AFTER PLUG-OFF ( DANGER 1.the dotted parts are optional for OF ELECTRIC SHOCK) different unit. THE CAPACITOR RETAINS HIGH VOLTA GE EVEN AFTER THE PLUG-OFF.FOR 2.The components of main pcb boa rd is YOUR SAFETY,BE SURE TO WAIT AT L EAST 5 MINUTES.AFTER PLUG OFF AN D USE A TESTER TO CONFIRM THE VOLT AGE BETWEEN CONNECTOR fixed facing to the compressor .