SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL HSU-07RS03/R2 HSU-09RS03/R2 HSU-12RS03/R2 HSU-18RS03/R2 HSU-22RS03/R2 H2SM-18HS03/R2 HSU-09HS03/R2(DB) HSU-12HS03/R2(DB) HSU-18HS03/R2(DB) HSU-22HS03/R2(DB) HSU-12HSB03/R2(DB) Please read this operation manual before using the air conditioner.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier. Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Cautions Do not obstruct or cover the ventilation grille of the air conditoner.Do not put fingers or any other things into the inlet/outlet and swing louver. Do not allow children to play with the air conditioner.In no case should children be allowed to sit on the outdoor unit.
Installation Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage. lnstallation in a inadequate place may cause accidents. Do not install in the following place.
Page 5
Cautions When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop. Connect power supply cord to the outlet completely STRICT ENFORCEMENT Do not use power supply cord in a bundle. PROHIBITION Do not start or stop the operation by disconnecting the power supply cord and so on.
Parts and Functions Indoor unit Display board Display board Inlet Anion generator (inside) Vertical flap (Use remote controller to adjust up and down air flow. Don't adjust it manually) Horizontal louver (adjust left and right air flow) For multi-split type, the power plug is on the outdoor unit Outdoor unit HSU-07RS03/R2 HSU-09RS03/R2...
Page 7
Parts and Functions 1. HEALTH button Used to set healthy operation. 2. HOUR button Used to set clock and timer setting. 3. MODE button Used to select operation mode. AUTO, COOL,DRY, FAN,HEAT. 4. SLEEP button Used to select sleep mode. 5.
Page 8
Parts and Functions Clock Set When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: 1. Press CLOCK button,"AM" or "PM" flashes. 2. Press to set correct time. Each press will increase or decrease 1 min.
Health Operation Remote controller BRIEF INTRODUCTION TO HEALTH OPERATION The anion generator in the air conditioner can generate a lot of anion to effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air the room.
Press FAN button. For each press, fan speed changes as follows: Remote controller: Air conditioner is running under displayed fan speed When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature. 4.Unit stop Press ON/OFF button, the unit stops.
Press FAN button. For each press, fan speed changes as follows: Remote controller: Air conditioner is running under displayed fan speed When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature. 5.Unit stop Press ON/OFF button, the unit stops.
Press FAN button. For each press, fan speed changes as follows: Remote controller: Air conditioner is running under displayed fan speed In DRY mode, when room temperature becomes 2 higher than temp.setting,unit will run intermittently at LOW speed regardless of FAN setting.
Operation Fan Operation Remote controller 1. Unit start Link with electronic power. Press ON/OFF on the remote controller, unit starts. The liquid crystal will display the working state of last time (Except Timer, Sleep, Power/Soft and Health airflow). 2.Select operation mode Press MODE button.
Air conditioner is running under displayed fan speed IN HEAT mode, warm air will blow out after a short period of the time due to cold-draft prevention function. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
Operation Air Flow Direction Adjustment 1.Status display of air sending direction 2.Up and down air flow direction For each press of as follows according to different operation modes: COOL/DRY/FAN: remote controller: Pos.1 HEAT: remote controller: Pos.5 AUTO: Pos.1 remote controller: The vertical flap will swing according to the above positions 3.Left and right air flow direction For each press of...
Operation Sleep Operation Before going to bed, you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep. Use of SLEEP function After the unit starts, set the operation status, then press SLEEP button before which the clock must be adjusted and time being set.
Operation Timer On/Off Operation Remote Controller Hints: After replacing batteries or a power failure happens, time setting should be reset. Remote controller possesses memory function, when use TIMER mode next time,just press SET button after mode selecting if time setting is the same as previous one. Set clock correctly before starting TIMER operation.
Operation Timer On-Off Operation Remote Controller Set clock correctly before starting TIMER operation. 1. After unit starts, select your desired operation mode Operation mode will be displayed on LCD. 2. Timer mode selection Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller: TIMER ON...
Operation POWER/SOFT Operation POWER Operation When you need rapid heating or cooling, you can use this function. Selecting of POWER operation Press POWER/SOFT button. Every time the button is pressed,display changes as follows: Stop the display at In POWER operation status: In HEAT or COOL mode, fan speed automatically runs in HI mode for 15 min then returns to original status setting.
2).Press the button of health airflow again, appears on the display. The above inlet and outlet grills of the air conditioner are closed and the airflow is blown vertically from the nether inlet and outlet grills. Avoid the strong airflow blows direct to the body.
Operation Emergency and Test Operation Emergency operation: Use this operation only when the remote controller is defective or lost. When the emergency operation switch is pressed,the" Pi "sound is heard once, which means the start of this operation. In this operation, the system automatically selects the operation modes, cooling or heating, according to the room temperature.
Maintenance For Smart Use of The Air Conditioner Setting of proper room temperature Close doors and windows during operation If the unit is not to be used for a long time, turn off the power supply main switch. Do not block the air inlet...
Close the inlet grille. Indoor Body Wipe the air conditioner by using a soft and dry cloth.For serious stains,use a neutral detergent diluted with water.Wring the water out of the cloth before wiping.then wipe off the detergent completely.
Maintenance Replacement of Air Purifying Filter 1.Open the lnlet Grille Open the inlet grille by pushing each ends of the inlet grille upward.(use thumbs to push 2.Detach the standard air filter Slide the knob slightly upward to release the filter, then withdraw it. 3.Detach old Air Purifying Filter 4.Attach old Air Purifying Filter Put air purifying filter appliances into the...
Maintenance To Keep Your Air conditioner in Good Condition after Season. Operate in cooling mode for 2-3 hours. To prevent breeding mold or bad smell, be sure to operate at the designated temperature or 30 mode and High speed fan mode for 2-3 hours.
Maintenance Before Setting in High season Cleaning the standard air filter. Operation without filter may cause troubles.Be sure to attach both right and left filters prior to the operation. Each of them are of different shapes. Connecting the cable. Incomplete earthing may cause an electric shock. Do not block the air inlet or outlet.
When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner. During unit operation or at stop, a swishing or gurgling noise may be heard. At first 2-3 minutes after unit start, this noise is more noticeable.