Summary of Contents for Mitsubishi Electric MXZ-4D80VA
Page 1
Split-type Air-Conditioner MXZ-4D80VA MXZ-5D100VA For INSTALLER Installation Manual English • This manual only describes the installation of outdoor unit. When installing the indoor unit, refer to the installation manual of indoor unit.
Indoor/outdoor Max. height Refrigerant adjust- Power supply per indoor unit / per indoor unit / Voltage quency capacity connecting wire difference *9 ment A *0 for multi-system for multi system MXZ-4D80VA 25 m / 70 m 25 / 70 4-core 230 V 50 Hz 25 A 3-core 2.5 mm 5 m 20 g/m .0 / .5 mm MXZ-5D00VA 25 m / 80 m 25 / 80 * Connect to the power switch which has a gap of 3 mm or more when *6 Refrigerant pipe bending radius must be 00 mm or more.
1-3. SELECTING OPTIONAL DIFFERENT-DIAMETER JOINTS If the diameter of connection pipe does not match the port size of outdoor unit, use optional different-diameter joints according to the following table. (Unit: mm (inch)) Optional different-diameter joints (port size of outdoor unit → diameter of connection pipe) Port size of outdoor unit 6.35 (/4) → 9.52 (3/8) : PAC-493PI MXZ- MXZ- Liquid / Gas 9.52 (3/8) → 2.7 (/2) : MAC-A454JP 4D80VA 5D00VA 9.52 (3/8) → 5.88 (5/8) : PAC-SG76RJ A UNIT 6.35 (/4) / 2.7 (/2) 2.7 (/2) → 9.52 (3/8) : MAC-A455JP 2.7 (/2) → 5.88 (5/8) : MAC-A456JP B - D UNIT B - E UNIT 6.35 (/4) / 9.52 (3/8) Refer to the installation manual of indoor unit for the diameter of connection pipe of indoor unit. 1-4. SELECTING THE INSTALLATION LOCATION • Where it is not exposed to strong wind.
1-5. INSTALLATION DIAGRAM ACCESSORIES After the leak test, apply insulat- Check the following parts before installation. ing material tightly so that there is no gap. () Drain socket When the piping is to be at- PARTS TO BE PROVIDED AT YOUR SITE tached to a wall containing metals (tin plated) or metal netting, use (A) Power supply cord* a chemically treated wooden piece 20 mm or thicker between (B) Indoor/outdoor unit connecting wire* the wall and the piping or wrap 7 (C) Extension pipe...
2. OUTDOOR UNIT INSTALLATION 2-1. INSTALLING THE UNIT • Be sure to fix the unit’s legs with bolts when installing it. • Be sure to install the unit firmly to ensure that it does not fall by an earthquake or a gust. • Refer to the figure in the right for concrete foundation. • Do not use the drain socket and the drain caps in the cold region. Drain may freeze and it makes the fan stop. Anchor leg Fix here with M0 bolts. Anchor both length Anchor both pitch Make the setting (Unit: mm) depth deeper. Make with wider. 2-2. CONNECTING WIRES FOR OUTDOOR UNIT ) Remove the service panel. Terminal block for power supply 2) Loosen terminal screw, and connect indoor/outdoor unit connecting wire (B) from the indoor unit correctly on the terminal block. Be careful not to make mis-wiring. Fix the wire to the terminal block securely so that no part of its core is appeared, and no external force is conveyed...
3. FLARING WORK AND PIPE CONNECTION 3-1. FLARING WORK ) Cut the copper pipe correctly with pipe cutter. (Fig. , 2) 2) Completely remove all burrs from the cut cross section of pipe. (Fig. 3) No good Good • Aim the copper pipe downward while removing burrs to prevent Copper burrs from dropping in the pipe. pipe 3) Remove flare nuts attached to indoor and outdoor units, then put them on pipe having completed burr removal. (Not possible to put them on after flaring work.) Tilted Uneven Burred 4) Flaring work (Fig. 4, 5). Firmly hold copper pipe in the dimension Fig. Fig. 2 shown in the table. Select A mm from the table according to the tool...
Page 7
) Be sure to turn off the main power for the air conditioner before making the setting. 2) Set the “3” of SW on the outdoor controller board to ON to enable this func- Lower the operating noise tion. 3) Turn on the main power for the air conditioner. 4-5. CHANGING THE AMPERE LIMIT • Description of the function: With this function, the amount of current that flows in the outdoor unit can be changed. MXZ-5D00VA MXZ-4D80VA Note: 0.5 A 0.5 A Use this function only when the amount of current exceeds the allowed value. 5.5 A 5.5 A [How to change the ampere limit] Factory setting Factory setting ) Be sure to turn off the main power for the air conditioner before making the...
4-6. TEST RUN • Test runs of the indoor units should be performed individually. See the installation manual coming with the indoor unit, and make sure all the units oper- ate properly. • If the test run with all the units is performed at once, possible erroneous connections of the refrigerant pipes and the indoor/outdoor unit connecting wires cannot be detected. Thus, be sure to perform the test run one by one. About the restart protective mechanism Once the compressor stops, the restart preventive device operates so the compressor will not operate for 3 minutes to protect the air conditioner. Wiring/piping correction function This unit has a wiring/piping correction function which corrects wiring and piping combination. When there is possibility of incorrect wiring and piping combi- nation, and confirming the combination is difficult, use this function to detect and correct the combination by following the procedures below. Make sure that the following is done. • Power is supplied to the unit. • Stop valves are open. Note: During detection, the operation of the indoor unit is controlled by the outdoor unit. During detection, the indoor unit automatically stops operation. This is not a malfunction. Procedure Press the piping/wiring correction switch (SW87) minute or more after turning on the power supply. LED indication during detection: • Correction completes in 0 to 5 minutes. When the correction is completed, its result is shown by LED indication. Details are described in the following table. LED LED2 LED3 • To cancel this function during its operation, press the piping/wiring correction switch (Red)