Cordless area-imaging scanner for healthcare and charge bases (18 pages)
Summary of Contents for Honeywell Hyperion 1300g
Page 1
Hyperion 1300g General Purpose Handheld Linear Scanner User’s Guide ™...
Page 2
Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in speci- fications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not repre- sent a commitment on the part of HII.
USB HID POS ............2-5 USB Serial Commands ..........2-5 USB Serial Emulation..........2-5 CTS/RTS Emulation ..........2-6 ACK/NAK Mode............. 2-6 Honeywell Bioptic Aux Port Configuration....2-6 ® Datalogic™ Magellan Bioptic Aux Port Configuration ............... 2-7 Wincor Mode A............2-7 Keyboard Country Layout ...........
Page 4
RS232 Modifiers ............2-19 RS-232 Baud Rate..........2-19 RS-232 Word Length: Data Bits, Stop Bits, and Parity..............2-20 RS-232 Handshaking..........2-22 RTS/CTS ............. 2-22 XON/XOFF ............2-22 ACK/NAK ............. 2-22 Chapter 3 - Input/Output Settings Good Read Indicators..........3-1 Beeper – Good Read ..........3-1 Beeper Volume –...
Page 5
Output Sequence Overview ........3-10 To Add an Output Sequence....... 3-10 Other Programming Selections ......3-11 Output Sequence Editor ........3-11 Require Output Sequence........3-11 Output Sequence Editor ........3-13 Require Output Sequence........3-13 Multiple Symbols ............3-14 No Read ..............3-15 Video Reverse............
Page 6
Data Format Editor Commands ........5-4 Send Commands ........... 5-4 Move Commands........... 5-7 Search Commands ..........5-8 Miscellaneous Commands........5-10 Data Format Editor ..........5-14 Data Formatter............. 5-14 Chapter 6 - Symbologies Introduction ..............6-1 All Symbologies ............6-2 Message Length ............6-2 Codabar ...............
Page 11
Caution: Any changes or modifications made to this equipment not expressly approved by Honeywell International Inc. may void the FCC authorization to operate this equipment. Note: To maintain compliance with EMC Regulations, cables connected to this device must be shielded cables. This unit has been tested with cables less than 3 meters.
Page 12
Note: Use only a Listed Limited Power Source (LPS) or Class 2 type power supply with output rated 5 to 5.2Vdc, 1A. Canada Industry Canada ICES-003 This Class B digital apparatus complies with Canadian ICES-003. Operation is subject to the following conditions: 1.
Page 13
Honeywell shall not be liable for use of our product with equipment (i.e., power supplies, personal computers, etc.) that is not CE marked and does not comply with the Low Voltage Directive. Waste Electrical and Electronic Equipment Information Honeywell complies with Directive 2002/96/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 27 January 2003 on waste electrical and electronic equipment (WEEE).
Page 14
Russia Australia/NZ C-Tick Statement Conforms to AS/NZS 3548 EMC requirements. Mexico Applicable if NOM logo is marked on product. Conforms to NOM-019. South Korea This product meets Korean agency approval. Taiwan BSMI Standard: CNS13438, CNS14336 依據標準 : CNS13438, CNS14336 International LED Safety Statement LEDs have been tested and classified as “EXEMPT RISK GROUP”...
Page 15
Solids and Water Protection The devices have a rating of IP41, immunity of foreign particles and dripping water tested to Standard EN60259. Patents For patent information, please refer to www.honeywellaidc.com/patents.
Page 16
Required Safety Label Locations Light Source Item Number, Serial Number Compliance Revision Label location...
Hyperion 1300g. Product specifications, dimensions, warranty, and customer support information are also included. Honeywell bar code scanners are factory programmed for the most common terminal and communications settings. If you need to change these settings, programming is accomplished by scanning the bar codes in this guide.
3. Verify the scanner operation by scanning a bar code from the Sample Symbols in the back of this manual. For additional USB programming and technical information, refer to the Honey- well “USB Application Note,” available at www.honeywellaidc.com. Connecting with Keyboard Wedge A scanner can be connected between the keyboard and PC as a “keyboard wedge,”...
Connecting with RS-232 Serial Port 1. Turn off power to the terminal/computer. 2. Connect the appropriate interface cable to the scanner. only if power supply is included 3. Plug the serial connector into the serial port on your computer. Tighten the two screws to secure the connector to the port.
1. Connect the appropriate interface cable to the device, then to the computer. 2. Turn the terminal/computer power back on. The scanner beeps. 3. Verify the scanner operation by scanning a bar code from the Sample Symbols in the back of this manual. The scanner beeps once. 4.
Menu Bar Code Security Settings Honeywell scanners are programmed by scanning menu bar codes or by send- ing serial commands to the scanner. If you want to restrict the ability to scan menu codes, you can use the Menu Bar Code Security settings.
Programming the Interface Introduction This chapter describes how to program your system for the desired interface. Programming the Interface - Plug and Play Plug and Play bar codes provide instant scanner set up for commonly used interfaces. Note: After you scan one of the codes, power cycle the host terminal to have the interface in effect.
RS232 Serial Port The RS232 Interface bar code is used when connecting to the serial port of a PC or terminal. The following RS232 Interface bar code also programs a car- riage return (CR) and a line feed (LF) suffix, baud rate, and data format as indi- cated below.
Each bar code above also programs the following suffixes for each symbology: Symbology Suffix Symbology Suffix EAN 8 Code 39 00 0A 0B EAN 13 Interleaved 2 of 5 00 0D 0B UPC A Code 128 * 00 0A 0B UPC E Code 128 ** 00 18 0B...
OPOS Mode USB IBM SurePos Scan the following “Plug and Play” codes to program the scanner for an IBM SurePos (USB handheld scanner) interface. Note: After scanning the code below, you must power cycle the cash register. USB IBM SurePos (USB Handheld Scanner) Interface USB IBM SurePos...
Scan the following code to program the scanner to emulate a regular RS232- based COM Port. If you are using a Microsoft® Windows® PC, you will need to download a driver from the Honeywell website (www.honeywellaidc.com). The driver will use the next available COM Port number. Apple® Macintosh comput- ers recognize the scanner as a USB CDC class device and automatically uses a class driver.
* ACK/NAK Mode Off Honeywell Bioptic Aux Port Configuration Scan the following Plug and Play code to program the scanner for a Honeywell bioptic scanner auxiliary port configuration. This bar code sets the baud rate to 38400 bps and the data format to 8 data bits, no parity, 1 stop bit. Character RTS/CTS with timeout and 232 ACK/NAK are also enabled.
® Datalogic™ Magellan Bioptic Aux Port Configuration Scan the following Plug and Play code to program the scanner for a Datalogic Magellan bioptic scanner auxiliary port configuration. This bar code sets the baud rate to 9600 bps and the data format to 8 data bits, no parity, 1 stop bit. Datalogic Magellan Bioptic Settings Note: If you are having unexpected results with this programming code, scan Activate Defaults...
Keyboard Country Layout Scan the appropriate country code below to program the keyboard layout for your country or language. As a general rule, the following characters are sup- ported, but need special care for countries other than the United States: @ | $ # { } [ ] = / ‘...
Page 31
Keyboard Country (continued) Canada (French legacy) Canada (French) Canada (Multilingual) China Croatia Czech Czech (Programmers) Czech (QWERTY) Czech (QWERTZ) Denmark Dutch (Netherlands) Estonia Faroese 2 - 9...
Page 33
Keyboard Country (continued) Hungary Iceland Ireland Italian (142) Italy Japan ASCII Kazakh Korea Kyrgyz (Cyrillic) Latin America Latvia Latvia (QWERTY) Lithuania Lithuania (IBM) 2 - 11...
Page 34
Keyboard Country (continued) Macedonia Malta Mongolian (Cyrillic) Norway Poland Polish (214) Polish (Programmers) Portugal Romania Russia Russian (MS) Russian (Typewriter) 2 - 12...
Page 35
Keyboard Country (continued) Serbia (Cyrillic) Serbia (Latin) Slovakia Slovakia (QWERTY) Slovakia (QWERTZ) Slovenia Spain Spanish variation Sweden Switzerland (French) Switzerland (German) Tatar Thailand 2 - 13...
Keyboard Country (continued) Turkey F Turkey Q Ukrainian United Kingdom United Stated (Dvorak right) United States (Dvorak left) United States (Dvorak) United States (International) Uzbek (Cyrillic) Vietnam Keyboard Mode Options ALT Mode If your bar code contains special characters from the extended ASCII chart for example, an e with an accent grave (è), you will use ALT Mode.
If your keystrokes require the ALT key and 4 characters, scan the 4 Characters bar code. The data is then output with the special character(s). Default = Off . * Off 4 Characters Keyboard Style This programs keyboard styles, such as Caps Lock and Shift Lock. Default = Regular.
Automatic Caps Lock is used if you change the Caps Lock key on and off. The software tracks and reflects if you have Caps Lock on or off (AT and PS/2 only). This selection can only be used with systems that have an LED, which notes the Caps Lock status.
Page 39
Default = Control + ASCII Off Windows Mode Control + X Mode On * Control + X Mode Off DOS Mode Control + X Mode Windows Mode Prefix/Suffix Off Numeric Keypad Mode: Sends numeric characters as if entered from a numeric keypad.
Page 40
Automatic Direct Connect Mode: This selection can be used if you have an IBM AT style terminal and the system is dropping characters. Default = Off Automatic Direct Connect Mode On * Automatic Direct Connect Mode Off 2 - 18...
RS232 Modifiers RS-232 Baud Rate Baud Rate sends the data from the scanner to the terminal at the specified rate. The host terminal must be set for the same baud rate as the scanner. Default = 38,400 . 1200 2400 4800 9600 19200...
* 38400 57,600 115,200 RS-232 Word Length: Data Bits, Stop Bits, and Parity Data Bits sets the word length at 7 or 8 bits of data per character. If an applica- tion requires only ASCII Hex characters 0 through 7F decimal (text, digits, and punctuation), select 7 data bits.
Page 43
Note: @ 7N1, the host must insert at least a 1 bit delay between characters otherwise use a different word format. 7 Data, 1 Stop, Parity Even 7 Data, 1 Stop, Parity None (see note above) 7 Data, 1 Stop, Parity Odd 7 Data, 2 Stop, Parity Even 7 Data, 2 Stop Parity None 7 Data, 2 Stop, Parity Odd...
RS-232 Handshaking RS232 Handshaking allows control of data transmission from the scanner using software commands from the host device. When RTS/CTS is turned Off, no data flow control is used. RTS/CTS The scanner asserts RTS when it has data to send, and waits indefinitely for CTS to be asserted by the host.
Page 45
for ACK/NAK again. Turn on the ACK/NAK protocol by scanning the ACK/NAK On bar code below. To turn off the protocol, scan ACK/NAK Off. Default = ACK/NAK Off. ACK/NAK On * ACK/NAK Off 2 - 23...
Input/Output Settings Good Read Indicators Beeper – Good Read The beeper may be programmed On or Off in response to a good read. Turning this option off, only turns off the beeper response to a good read indication. All error and menu beeps are still audible. Default = On. * On Beeper Volume –...
Beeper Pitch – Good Read The beeper pitch codes modify the pitch (frequency) of the beep the scanner emits on a good read. Default = Medium Low (1600 Hz) * Medium (2750 Hz) High (4200 Hz) Beeper Duration – Good Read The beeper duration codes modify the length of the beep the scanner emits on a good read.
Beeper Pitch – Error The beeper pitch codes modify the pitch (frequency) of the sound the scanner emits when there is a bad read or error. Default = 100 Hz. * Razz (100 Hz) * Medium (2000 Hz) High (4200 Hz) LED –...
LED flashes are in sync with one another. To change the number of beeps, scan the bar code below and then scan a digit (1-9) bar code and the Save bar code on the inside the back cover of this manual. Default = One. Number of Pulses Good Read Delay This sets the minimum amount of time before the scanner can read another bar...
Trigger Modes Manual/Serial Trigger You can activate the scanner either by pressing the trigger, or using a serial trig- ger command (see Trigger Commands on page 9-4). When in manual trigger mode, the scanner scans until a bar code is read, or until the trigger is released. When in serial mode, the scanner scans until a bar code has been read or until the deactivate command is sent.
Presentation Mode Presentation Mode uses ambient light to detect bar codes. The LEDs are off for ambient conditions until a change occurs in the scanner’s field of view. Then the LEDS turn on automatically to read the code. If the light level in the room is not high enough, Presentation Mode may not work properly.
Scan the Hands Free Time-Out bar code, then scan the time-out duration (from 0-300,000 milliseconds) from the inside back cover, and Save . Default = 5,000 ms. Hands Free Time-Out Reread Delay This sets the time period before the scanner can read the same bar code a sec- ond time.
User-Specified Reread Delay If you want to set your own length for the reread delay, scan the bar code below, then set the delay (from 0-30,000 milliseconds) by scanning digits from the inside back cover, then scanning Save . User-Specified Reread Delay Centering Use Centering to narrow the scanner’s field of view to make sure the scanner reads only those bar codes intended by the user.
Page 55
Centering On * Centering Off Left of Centering Window Right of Centering Window 3 - 9...
Output Sequence Overview Require Output Sequence When turned off, the bar code data will be output to the host as the scanner decodes it. When turned on, all output data must conform to an edited sequence or the scanner will not transmit the output data to the host device. Note: This selection is unavailable when the Multiple Symbols Selection is turned on.
Other Programming Selections • Discard This exits without saving any Output Sequence changes. Output Sequence Editor Enter Sequence Default Sequence Require Output Sequence When an output sequence is Required , all output data must conform to an edited sequence or the scanner will not transmit the output data to the host device.
Page 58
Output Sequence Example In this example, you are scanning Code 93, Code 128, and Code 39 barcodes, but you want the image scanner to output Code 39 1st, Code 128 2nd, and Code 93 3rd, as shown below. Note: Code 93 must be enabled to use this example. A - Code 39 B - Code 128 C - Code 93...
The breakdown of the command line is shown below: SEQBLK sequence editor start command code identifier for Code 39 0012 A - Code 39 sample length (11) plus CR suffix (1) = 12 start character match for Code 39, 41h = “A” termination string for first code code identifier for Code 128 0013...
When the output sequence is Off , the barcode data is output to the host as the image scanner decodes it. Note: This selection is unavailable when the Multiple Symbols Selection is turned on. Required On/Not Required *Off Multiple Symbols When this programming selection is turned On , it allows you to read multiple symbols with a single pull of the scanner’s trigger.
No Read With No Read turned On , the scanner sends an “NR” to the host if you pull and release the trigger without reading a code (e.g., bad bar code). If No Read is turned Off , the “NR” will not be sent to the host. * Off If you want a different notation than “NR,”...
Data Editing Prefix/Suffix Overview When a bar code is scanned, additional information is sent to the host computer along with the bar code data. This group of bar code data and additional, user-defined data is called a “message string.” The selections in this section are used to build the user-defined data into the message string.
Step 3. Scan the 2 hex digits from the inside the back cover of this manual or scan 9, 9 for all symbologies. Step 4. Determine the hex value from the ASCII Conversion Chart (Code Page 1252) on page A-2, for the prefix or suffix you wish to enter. Step 5.
Step 3. Scan the 2 digit hex value from the inside the back cover of this man- ual or scan 9, 9 for all symbologies. Your change is automatically saved. To Add a Carriage Return Suffix to All Symbologies Scan the following bar code if you wish to add a carriage return suffix to all sym- bologies at once.
Suffix Selections Add Suffix Clear One Suffix Clear All Suffixes Transmit Alternate Extended ASCII Characters You may need to emulate special keyboard functions, such as up or down arrows, Alt/Make or Alt/Break commands, that are not supported in the Extended ASCII Character table. Refer to Alternate Extended ASCII Charac- ters (page 4-5) for a range of keyboard function keys and corresponding deci-...
Page 67
Alternate Extended ASCII Characters DEC HEX Keyboard Function DEC HEX Keyboard Function ↑ 128 80 152 98 up arrow ↓ 129 81 153 99 down arrow → 130 82 154 9A right arrow ← 131 83 155 9B left arrow 132 84 Insert 156 9C Numeric Keypad +...
Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function code to the terminal. Charts of these function codes are provided in Supported Interface Keys starting on page 7-2.
Intercharacter Delay An intercharacter delay of up to 495 milliseconds may be placed between the transmission of each character of scanned data. Scan the Intercharacter Delay bar code below, then scan the number of steps in 5 millisecond incre- ments and the Save bar code using the inside the back cover of this manual. Prefix Scanned Data Suffix...
To remove this delay, scan the Delay Length bar code, and set the number of steps to 0. Scan the Save bar code using the inside the back cover of this manual. Interfunction Delay An interfunction delay of up to 495 milliseconds may be placed between the transmission of each control character in the message string.
Page 71
To remove this delay, scan the Intermessage Delay bar code, then set the number of steps to 0. Scan the Save bar code using the inside the back cover of this manual. 4 - 9...
Data Formatting Data Format Editor Introduction You may use the Data Format Editor to change the scanner’s output. For exam- ple, you can use the Data Format Editor to insert characters at certain points in bar code data as it is scanned. The selections in the following pages are used only if you wish to alter the output.
Step 3. Terminal Type Refer to the Supported Terminals Chart (page 5-4) and locate the Ter- minal ID number for your PC. Scan three numeric bar codes on the inside back cover to program the scanner for your terminal ID (you must enter 3 digits).
Page 75
format you are clearing. Scan the Terminal Type (refer to the Supported Terminals Chart on page 5-4), Code I.D. (refer to the Symbology Chart page A-1), and the bar code data length for the specific data format that you want to delete. All other formats remain unaffected. •...
Interface / Terminal ID Table Terminal Model(s) Terminal ID PC keyboard (HID) Mac Keyboard PC Keyboard (Japanese) Serial (COM driver required) HID POS USB SurePOS Handheld USB SurePOS Tabletop Serial RS232 TTL RS232 True RS485 (IBM-HHBCR 1+2, 46xx) Keyboard PS2 compatibles AT compatibles Data Format Editor Commands When working with the Data Format Editor, a virtual cursor is moved along your...
Page 77
F2 Example: Send a number of characters Send the first 10 characters from the bar code above, followed by a carriage return. Command string: F2100D F2 is the “Send a number of characters” command 10 is the number of characters to send 0D is the hex value for a CR The data is output as: 1234567890 F2 and F1 Example: Split characters into 2 lines...
Page 78
The data is output as: 1234567890AB <tab><tab> Insert symbology name B3 Insert the name of the bar code’s symbology in the output message, without moving the cursor. Only symbologies with a Honeywell ID are included (see Symbology Chart on page A-1). Refer to the...
Insert bar code length B4 Insert the bar code’s length in the output message, without moving the cursor. The length is expressed as a numeric string and does not include leading zeroes. B3 and B4 Example: Insert the symbology name and length Send the symbology name and length before the bar code data from the bar code above.
03 is the number of characters to move the cursor F1 is the “Send all characters” command 0D is the hex value for a CR The data is output as: 4567890ABCDEFGHIJ <CR> Move the cursor backward a number of characters F6 Move the cursor back “nn”...
Page 81
Search backward for a character F9 Search the input message backward for “xx” character from the current cursor position, leaving the cursor pointing to the “xx” character. Syntax = F9xx where xx stands for the search character’s hex value for the CP1252 character.
Search forward for a non-matching character E6 Search the input message forward for the first non-“xx” character from the current cursor position, leaving the cursor pointing to the non-“xx” character. Syntax = E6xx where xx stands for the search character’s hex value for the CP1252 character.
Page 83
FB Example: Remove spaces in bar code data This example shows a bar code that has spaces in the data. You may want to remove the spaces before sending the data. Using the bar code above: Command string: FB0120F10D FB is the “Suppress characters” command 01 is the number of character types to be suppressed 20 is the hex value for a space F1 is the “Send all characters”...
Page 84
F1 is the “Send all characters” command 0D is the hex value for a CR The data is output as: 1234 5678 <CR> Stop replacing characters E5 Terminates character replacement. Syntax = E5. Compare characters FE Compare the character in the current cursor position to the character “xx.”...
Page 85
If this bar code is read: the data is output as: 1234AB <CR> Check for non-numeric character ED Check to make sure there is a non-numeric ASCII character at the current cursor position. The format is aborted if the character is numeric.
Data Format Editor Enter Data Format * Default Data Format Clear One Data Format Clear All Data Formats Save Discard Data Formatter When Data Formatter is turned off, the bar code data is output to the host as read (including prefixes and suffixes). Choose one of the following options. 5 - 14...
Page 87
Default = Data Formatter On. * Data Formatter On, but Not Required Data Formatter Off When Data Formatter is required, all input data must conform to an edited for- mat or the scanner does not transmit the input data to the host device. Data Format On, Format Required 5 - 15...
Symbologies Introduction This programming section contains the following menu selections. Refer to Chapter 9 for settings and defaults. • All Symbologies • GS1 DataBar Expanded • China Post Code • Interleaved 2 of 5 • Codabar • Label Code • Codablock F •...
All Symbologies If you want to decode all the symbologies allowable for your scanner, scan the All Symbologies On code. If on the other hand, you want to decode only a particular symbology, scan All Symbologies Off followed by the On symbol for that particular symbology.
EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15 For a value other than the minimum and maximum message length defaults, scan the bar codes included in the explanation of the symbology, then scan the digit value of the message length and Save bar codes on the inside the back...
Default = Don’t Transmit . Transmit * Don’t Transmit Codabar Check Character Codabar check characters are created using different “modulos.” You can pro- gram the scanner to read only Codabar bar codes with Modulo 16 check char- acters. Default = No Check Character. No Check Character indicates that the scanner reads and transmits bar code data with or without a check character.
Codabar Concatenation Codabar supports symbol concatenation. When you enable concatenation, the scanner looks for a Codabar symbol having a “D” start character, adjacent to a symbol having a “D” stop character. In this case the two messages are concat- enated into one with the “D” characters omitted. Character Start Stop...
Codabar Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 2-60. Minimum Default = 4, Maximum Default = 60. Minimum Message Length Maximum Message Length 6 - 6...
Code 39 < Default All Code 39 Settings > Code 39 Code 39 Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit. Transmit * Don’t Transmit Code 39 Check Character...
When Check Character is set to Validate and Transmit, the scanner only reads Code 39 bar codes printed with a check character, and will transmit this charac- ter at the end of the scanned data. Default = No Check Character. * No Check Character Validate, but Don’t Transmit Validate and Transmit...
are read, deleting the first space from each. The scanner transmits the appended data when it reads a Code 39 bar code that starts with a character other than a space. Default = Off. *Off Code 32 Pharmaceutical (PARAF) Code 32 Pharmaceutical is a form of the Code 39 symbology used by Italian pharmacies.
Full ASCII If Full ASCII Code 39 decoding is enabled, certain character pairs within the bar code symbol will be interpreted as a single character. For example: $V will be decoded as the ASCII character SYN, and /C will be decoded as the ASCII character #.
Code Page Mapping of Printed Bar Codes on page A-5, and scan the value and the Save bar code from the inside the back cover of this manual. The data characters should then appear properly. Code 39 Code Page Interleaved 2 of 5 <...
When Check Digit is set to Validate and Transmit, the scanner only reads Interleaved 2 of 5 bar codes printed with a check digit, and will transmit this digit at the end of the scanned data. Default = No Check Digit. * No Check Digit Validate, but Don’t Transmit Validate and Transmit...
Code 93 < Default All Code 93 Settings > Code 93 * On Code 93 Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 0-80.
Page 102
select the code page with which the bar codes were created from the chart, Code Page Mapping of Printed Bar Codes on page A-5, and scan the value and the Save bar code from the inside the back cover of this manual. The data characters should then appear properly.
Straight 2 of 5 Industrial (three-bar start/stop) <Default All Straight 2 of 5 Settings> Straight 2 of 5 Industrial * On Straight 2 of 5 Industrial Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information.
Straight 2 of 5 IATA (two-bar start/stop) <Default All Code IATA 2 of 5 Settings> Straight 2 of 5 IATA Straight 2 of 5 IATA Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information.
Matrix 2 of 5 <Default All Matrix 2 of 5 Settings> Matrix 2 of 5 * Off Matrix 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 1-80.
Code 11 <Default All Code 11 Settings> Code 11 * Off Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11 bar codes. Default = Two Check Digits. One Check Digit * Two Check Digits 6 - 18...
Code 11 Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80. Minimum Message Length Maximum Message Length Code 128 <Default All Code 128 Settings>...
space-efficient design, 3) a variation of Code 128 that supports concatenation of neighboring symbols, and 4) the standard layout for bar codes on a blood product label. Use the bar codes below to turn concatenation on or off. Default =Off. * Off Code 128 Message Length Scan the bar codes below to change the message length.
Code 128 Code Page Code 128 Function Code Transmit By default, Code 128 function codes are not transmitted with Code 128 bar code data. However, if you wish to transmit Code 128 function codes with the bar code data, scan the Function Codes On bar code, below. Default = Off * Function Codes Off Function Codes On Telepen...
Telepen * Off Telepen Output Using AIM Telepen Output, the scanner reads symbols with start/stop pattern 1 and decodes them as standard full ASCII (start/stop pattern 1). When Original Telepen Output is selected, the scanner reads symbols with start/stop pattern 1 and decodes them as compressed numeric with optional full ASCII (start/stop pattern 2).
Telepen Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 1-60. Minimum Default = 1, Maximum Default = 60. Minimum Message Length Maximum Message Length 6 - 23...
UPC A <Default All UPC A Settings> UPC A * On UPC A Check Digit This selection allows you to specify whether the check digit should be transmit- ted at the end of the scanned data or not. Default = On . * On 6 - 24...
UPC A Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it. Default = On. * On UPC A Addenda This selection adds 2 or 5 digits to the end of all scanned UPC A data.
UPC A Addenda Required When Addenda Required is set to on, the scanner will only read UPC A bar codes that have addenda. Default = Not Required. Required * Not Required UPC A Addenda Separator When this feature is on, there is a space between the data from the bar code and the data from the addenda.
UPC-A/EAN-13 with Extended Coupon Code Use the following codes to enable or disable UPC-A and EAN-13 with Extended Coupon Code. Default = On. * Off 6 - 27...
UPC E <Default All UPC E Settings> UPC E0 and UPC E1 Most U.P.C. bar codes lead with the 0 number system. For these codes, use the UPC E0 selection. If you need to read codes that lead with the 1 number system, use the UPC E1 selection.
UPC E0 and UPC E1 Expand UPC E Expand expands the UPC E code to the 12 digit, UPC A format. Default = Off. * Off UPC E0 and UPC E1 Addenda Required When Addenda Required is set to on, the scanner will only read UPC E bar codes that have addenda.
UPC E0 and UPC E1 Addenda Separator When this feature is on, there is a space between the data from the bar code and the data from the addenda. When turned off, there is no space. Default = On. * On UPC E0 Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not.
UPC E0 Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it. Default = On. * On UPC E0 Addenda This selection adds 2 or 5 digits to the end of all scanned UPC E data.
EAN/JAN 13 <Default All EAN/JAN Settings> EAN/JAN 13 * On EAN/JAN 13 Check Digit This selection allows you to specify whether the check digit should be transmit- ted at the end of the scanned data or not. Default = On. * On 6 - 32...
EAN/JAN 13 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN 13 data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off EAN/JAN 13 Addenda Required When Addenda Required is set to on, the scanner will only read EAN/JAN 13...
EAN/JAN 13 Addenda Separator When this feature is on, there is a space between the data from the bar code and the data from the addenda. When turned off, there is no space. Default = On. * On Note: If you want to enable or disable EAN13 with Extended Coupon Code, refer to UPC-A/EAN-13 with Extended Coupon Code on page 6-27.
EAN/JAN 8 * On EAN/JAN 8 Check Digit This selection allows you to specify whether the check digit should be transmit- ted at the end of the scanned data or not. Default = On. * On 6 - 35...
EAN/JAN 8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN 8 data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda * 5 Digit Addenda Off EAN/JAN 8 Addenda Required...
EAN/JAN 8 Addenda Separator When this feature is on, there is a space between the data from the bar code and the data from the addenda. When turned off, there is no space. Default = On. * On <Default All MSI Settings> * Off MSI Check Character Different types of check characters are used with MSI bar codes.
When Check Character is set to Validate and Transmit , the scanner will only read MSI bar codes printed with the specified type check character, and will transmit this character at the end of the scanned data. When Check Character is set to Validate, but Don’t Transmit , the unit will only read MSI bar codes printed with the specified type check character, but will not transmit the check character with the scanned data.
Plessey Code * Off Plessey Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 4-48. Minimum Default = 4, Maximum Default = 48. Minimum Message Length Maximum Message Length GS1 DataBar Omnidirectional...
GS1 DataBar Expanded * On GS1 DataBar Expanded Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 4-74. Minimum Default = 4, Maximum Default = 74. Minimum Message Length Maximum Message Length China Post Code...
Page 130
China Post Code * Off China Post Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80. Minimum Message Length Maximum Message Length 6 - 42...
Korea Post Code <Default All Korea Post Code Settings> Korea Post Code * Off Korea Post Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 2-80.
Codablock F <Default All Codablock F Settings> Codablock F * Off Codablock F Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 1-2048. Minimum Default = 1, Maximum Default = 2048. Minimum Message Length Maximum Message Length 6 - 44...
Code 49 <Default All Code 49 Settings> Code 49 * Off Code 49 Message Length Scan the bar codes below to change the message length. Refer to Message Length on page 6-2 for additional information. Minimum and Maximum lengths = 1-81. Minimum Default = 1, Maximum Default = 81. Minimum Message Length Maximum Message Length 6 - 45...
Trioptic Code Trioptic Code is used for labeling magnetic storage media. GS1 Emulation The scanner can automatically format the output from any GS1 data carrier to emulate what would be encoded in an equivalent GS1-128 or GS1 DataBar symbol. GS1 data carriers include UPC-A and UPC-E, EAN-13 and EAN-8, ITF-14, GS1-128, and GS1-128 DataBar and GS1Composites.
Interface Keys Keyboard Function Relationships The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII “CTRL”+ relationships apply to all terminals that can be used with the scanner. Refer to page 2-17 enable Control + ASCII mode. Function Code HEX/ASCII Value Full ASCII “CTRL”...
Supported Interface Keys IBM AT/XT and PS/2 Compatibles, WYSE PC/AT ASCII Supported Keys Reserved Enter (KP) Cap Lock ALT make ALT break CTRL make CTRL break CR/Enter Reserved Reserved Delete CR/Enter Insert Escape Home Print Back Space Back Tab * IBM 3191/92, 3471/72, 3196/97, 3476/77, Telex (all models) 7 - 2...
Page 139
Supported Interface Keys Apple Mac/iMac ASCII Supported Keys Reserved Enter/Numpad Enter CAPS ALT make ALT break CNTRL make CNTRL break RETURN APPLE make APPLE break RETURN Ins Help Home Prnt Scrn BACKSPACE LSHIFT TAB BACKSPACE 7 - 3...
Utilities To Add a Test Code I.D. Prefix to All Symbologies This selection allows you to turn on transmission of a Code I.D. before the decoded symbology. (See the Symbology Chart, included in the "Appendix A" on page A-1) for the single character code that identifies each symbology.) This action first clears all current prefixes, then programs a Code I.D.
Resetting the Standard Product Defaults If you aren’t sure what programming options are in your scanner, or you’ve changed some options and want the standard product default settings restored, scan the Standard Product Default Settings bar code below. Standard Product Default Settings Menu Commands starting on page 9-5...
Note: EZConfig requires .NET software. If .NET is not installed on your PC, you will be prompted to install it during the EZConfig installation. 1. Access the Honeywell web site at www.honeywellaidc.com 2. Click on the Resources tab. Select Product Downloads-Software.
Serial Programming Commands The serial programming commands can be used in place of the programming bar codes. Both the serial commands and the programming bar codes will pro- gram the scanner. For complete descriptions and examples of each serial pro- gramming command, refer to the corresponding programming bar code in this manual.
Query Commands Several special characters can be used to query the device about its settings. What is the default value for the setting(s). What is the device’s current value for the setting(s). What is the range of possible values for the setting(s). (The de- vice’s response uses a dash (-) to indicate a continuous range of values.
Examples of Query Commands In the following examples, a bracketed notation [ ] depicts a non-displayable response. Example: Example #1:What is the range of possible values for Codabar Coding Enable? Enter: cbrena*. Response: CBRENA0-1[ACK] This response indicates that Codabar Coding Enable (CBRENA) has a range of values from 0 to 1 (off and on).
Trigger Commands You can activate and deactivate the scanner with serial trigger commands. First, the scanner must be put in Manual/Serial Trigger Mode either by scanning the Manual/Serial Trigger Mode bar code (page 3-5), or by sending the Manual/ Serial Menu Command (page 9-12).
Menu Commands Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry Product Default Settings Resetting the Factory Remove Custom DEFOVR Defaults Defaults Activate Defaults DEFALT Programming the Interface Plug and Play Codes Keyboard Wedge: IBM PAP_AT PC AT and Compati- bles with CR suffix RS232 Serial Port...
Page 150
Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry Plug and Play Codes: Honeywell Bioptic Aux PAPBIO Port Datalogic Magellan PAPMAG Bioptic Aux Port Wincor Mode A PAPWMA Program Keyboard *U.S.A. KBDCTY0 Country Albania KBDCTY35 Arabic...
Page 151
Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry Program Keyboard Czech (Programmers) KBDCTY40 Country (continued) Czech (QWERTY) KBDCTY39 Czech (QWERTZ) KBDCTY38 Denmark KBDCTY8 Dutch (Netherlands) KBDCTY11 Estonia KBDCTY41 Faroese KBDCTY83 Finland KBDCTY2 2-10 France KBDCTY3 2-10 Gaelic KBDCTY84...
Page 152
Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry Program Keyboard Latvia KBDCTY42 2-11 Country (continued) Latvia (QWERTY) KBDCTY43 2-11 Lithuania KBDCTY44 2-11 Lithuania (IBM) KBDCTY45 2-11 Macedonia KBDCTY34 2-12 Malta KBDCTY74 2-12 Mongolian (Cyrillic) KBDCTY86 2-12 Norway KBDCTY9...
Page 153
Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry Program Keyboard Turkey F KBDCTY27 2-14 Country (continued) Turkey Q KBDCTY24 2-14 Ukrainian KBDCTY76 2-14 United Kingdom KBDCTY7 2-14 United Stated (Dvorak KBDCTY89 2-14 right) United States (Dvorak KBDCTY88 2-14 left)
Page 154
Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry Keyboard Modifiers Windows Mode Con- KBDCAS2 2-17 trol + X Mode On *Control + X Off KBDCAS0 2-17 DOS Mode Control + KBDCAS1 2-17 X Mode On Windows Mode Prefix/ KBDCAS3 2-17...
Standard Connector Pinouts Keyboard Wedge 10 Pin RJ41 Modular Plug - connects to the scanner handle 1 Cable shield 2 Tied to supply power 3 Supply ground 4 Terminal data 5 Terminal clock 6 Keyboard clock 7 Supply power input +5V power 8 Keyboard data Serial Output 10 Pin RJ41 Modular Plug - connects to the scanner handle...
Inspect the scanner’s interface cable and connector for wear or other signs of damage. A badly worn cable or damaged connector may interfere with scanner operation. Contact your Honeywell distributor for information about cable replacement. Cable replacement instructions are on page 11-2.
The interface cable is designed to be field replace- able. • Order replacement cables from Honeywell or from an authorized distributor. • When ordering a replacement cable, specify the cable part number of the original interface cable.
Page 171
Is the scanner having trouble reading your symbols? If the scanner isn’t reading symbols well, check that the symbols: • Aren’t smeared, rough, scratched, or exhibiting voids. • Aren’t coated with frost or water droplets on the surface. • Are enabled in the scanner or in the decoder to which the scanner connects. Is the bar code displayed but not entered? The bar code is displayed on the host device correctly, but you still have to press a key to enter it (the Enter/Return key or the Tab key, for example).
For our latest contact information, please check our website at the link above. Product Service and Repair Honeywell International Inc. provides service for all of its products through service centers throughout the world. To obtain warranty or non-warranty service, please visit www.honeywellaidc.com...
Page 174
This includes but is not limited to: cables, power supplies, cradles, and docking stations. HII extends these warranties only to the first end-users of the products. These warranties are non-transferable. The duration of the limited warranty for the Hyperion 1300g is five (5) years. 12 - 2...
Appendix A Symbology Chart Possible AIM Code ID Symbology AIM ID ID Modifiers (hex) ( m ) All Symbologies (0x99) China Post Q (0x51) Codabar a (0x61) Codablock F 0, 1, 4, 5, 6 q (0x71) Code 11 h (0x68) Code 128 0, 1, 2, 4 j (0x6A)
Possible AIM Code ID Symbology AIM ID ID Modifiers (hex) ( m ) UPC-E E (0x45) UPC-E with Add-On E (0x45) UPC-E1 (obsolete) E (0x45) Note: “m” represents the AIM modifier character. Refer to International Technical Specification, Symbology Identifiers, for AIM modifier character details.
Page 179
SI (SHIFT IN) UNIT SEPARATOR (US) DOWN ARROW Printable Characters DEC HEX Character DEC HEX Character DEC HEX Character <SPACE> " & < > <DEL> A - 3...
Page 180
Extended ASCII Characters DEC HEX Character DEC HEX Character DEC HEX Character € € « Ö ¬ × ‚ Ø ƒ ® Ù „ ¯ Ú … ° Û † ± Ü ‡ ² Ý ˆ ³ Þ ‰ ´ ß...
Page 182
code being scanned was created using a code page that is different from the one the host program is expecting. If this is the case, select the code page with which the bar codes were created. The data characters should then appear properly.
Programming Chart Save Discard Note: If you make an error while scanning the letters or digits (before scanning Save), scan Discard, scan the correct letters or digits, and Save again.
Page 188
Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.com HP1300-UG Rev B 9/12...
Need help?
Do you have a question about the Hyperion 1300g and is the answer not in the manual?
Questions and answers