Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HII.
Card Slot Scanner / Imager Port Bluetooth LXEZ Pairing Keypads Using the 55 Key Alpha-Numeric Keypad Using the 32 Key Numeric-with Triple-Click Alpha Display Display Backlight Timer Status LEDs MX7 Cold Storage Configuration 2-10 Cold Storage Battery 2-10 Snowflake Decal 2-10...
Page 4
Clearing Persistent Storage / Reset to Default Settings Folders Copied at Startup Saving Changes to the Registry Software Load Software Applications Bluetooth (Optional) Java (Optional) RFTerm (Optional) Avalanche Software Development Access Files on the Flash Card MX7 Utilities LAUNCH.EXE LAUNCH.EXE and Persistent Storage...
Page 5
REGEDIT.EXE REGLOAD.EXE REGDUMP.EXE WARMBOOT.EXE WAVPLAY.EXE MX7 Command-line Utilities COLDBOOT.EXE PrtScrn.EXE Desktop Desktop Icons Taskbar 4-10 My Device Folders 4-11 Wavelink Avalanche Enabler (Optional) 4-11 Internet Explorer 4-12 Start Menu Program Options 4-12 Communication 4-13 ActiveSync 4-13 Connect and LXEConnect 4-13...
Page 6
About 4-24 Version Tab and the Registry 4-24 Language and Fonts 4-24 Identifying Software Versions 4-25 MAC Address 4-25 Accessibility 4-26 Administration (for AppLock) 4-28 Introduction 4-28 Factory Default Settings - AppLock 4-29 Setup a New Device 4-30 Administration Mode 4-31 End User Mode 4-32...
Page 7
Bluetooth Printer Setup 4-77 Easy Pairing and Auto-Reconnect 4-77 Using OPP 4-78 Pairing with an OPP Device 4-78 Remote Device Pushes File to MX7 4-78 MX7 Pushes File to Remote Device 4-79 LXEZ Pairing and External Application 4-79 Certificates 4-80...
Page 9
Scanner Wedge Introduction 4-122 Bar Code Readers 4-123 Return to Factory Default Settings 4-123 Bar Code Processing Overview 4-124 Factory Default Settings 4-125 Main Tab 4-126 COM1 Tab 4-128 Barcode Tab 4-129 Buttons 4-130 Continuous Scan Mode 4-131 Enable Code ID 4-132 Bar Code –...
Page 10
Synchronizing from the Mobile Device Explore Backup Data Files using ActiveSync Connect Disconnect Cold Boot and Loss of Host Re-connection ActiveSync Help Configuring the MX7 with LXEConnect Install LXEConnect Using LXEConnect Chapter 6: Enabler Installation and Configuration Introduction Installation Installing the Enabler...
Page 11
Taskbar 6-17 Execution 6-18 Scan Config 6-19 Shortcuts 6-20 SaaS 6-21 Adapters 6-22 Status 6-25 Startup/Shutdown 6-26 Exit 6-27 Using Remote Management 6-28 Using eXpress Scan 6-29 Step 1: Create Bar Codes 6-29 Step 2: Scan Bar Codes 6-29 Step 3: Process Completion 6-31 Chapter 7: Wireless Network Configuration Introduction...
Page 12
Environmental Specifications Network Card Specifications Summit 802.11 b/g CF 2.4GHz Summit 802.11a/b/g CF 2.4/5.0GHz Bluetooth Chapter 10: Autovision Keypad 10-1 Introduction 10-1 AppLock and the MX7 Autovision Keypad 10-2 Hot Key 10-2 Global Key 10-2 Backdoor Key 10-2 Autovision Key Map...
Tap the Accept button to accept the EULA terms and the MX7 continues the startup process. The EULA is not presented to the user again. Tap the Decline button to decline the EULA and the MX7 will reboot. It will continue to reboot until the Accept button is tapped with the stylus.
Components Front 1. Scanner/Imager Aperture 6. Blue Key (Sticky Key) 2. Speaker 7. Scan Status LED 3. System Status LED 8. Cable Port 4. Scan Button 9. On / Off Button 5. Orange Key (Sticky Key) 10. Alpha Lock LED (32 Key keypad only) Diamond Keys...
I/O Port and Cables Cable: Multipurpose RS-232 and Power MX7055CABLE Cable: Multipurpose USB and Power MX7052CABLE Adapter/Cable : Audio MX7060CABLE...
Page 17
Adapter: RS-232 PC port to D9 male MX7058CABLE...
Scanner / Imager Aperture Caution: Never stare directly into the beam aperture. If Continuous Scan Mode has been enabled (default is disabled), the laser is always on and decoding. Caution: Laser beam is emitted continuously. Do not stare into the laser beam. Handle 1.
Warm Boot Start > Run In warm boot, the MX7 reloads the operating system and CAB files from the internal SD card and the preserved registry is also reloaded. Anything not saved or preserved to the registry is lost. Hold down the Power key for 15 seconds until the display blanks, then release the key.
(in a linear fashion) and never just stop working. This last more than a few hours. is important to remember – the MX7 is always ‘on’ even when in the Suspend state and draws a small amount of battery power at all times.
802.11b/g and a/b/g Wireless Client The MX7 has a 802.11 network card that supports diversity with two internal antennas. The CPU board does not allow hot swapping the network card. Adjusting power management on the network card is set to static dynamic control. WEP, WPA and LEAP are supported.
Internal SD Memory Card The MX7 has one SD card interface for storage of operating system and program code, as well as persistent storage. The SD slot is accessible from the battery compartment and ships with a 128MB SD Flash card. Larger capacity flash cards are available.
The MX7 status indicator is illuminated when the backup battery is being charged by the main battery pack. A new main battery pack can be fully charged in 6 hours when it is in an MX7 connected to AC power and 3.5 hours when it is in the MX7 battery charger.
Speaker The speaker supplies audible verification signals normally used by the Window’s CE operating system. The speaker is located on the front of the MX7, above the MX7 logo. The mobile device emits a Sound Pressure Level (loudness) of at least...
Code93i, Matrix 2 of 5 or Telepen symbologies. The integrated scan engine activates when the Scan button on the front of the MX7 is depressed or when the trigger on an installed trigger handle is depressed. A control panel applet (Start > Settings > Control Panel > Scanner) is available to set scanner/imager options.
Keypads Using the 55 Key Alpha-Numeric Keypad There are three options available for the 55 key keypad: 1. ANSI Primary Delete 2. 5250 Primary Delete. 5250 commands are displayed on the keypad overlay next to the affected keys. 3. ANSI Primary Backspace. This keypad resembles the ANSI Primary Delete keypad with the exception that the Del key function on the ANSI Primary Delete keypad is replaced by the BkSp key function.
Using the 32 Key Numeric-with Triple-Click Alpha When using a sequence of keys that require an alpha key, first press the Alph key. Use the Shft sticky key or the Caps key sequence (Blue+Tab) for upper case alphabetic characters. Pressing the Alph key forces “Alpha” mode for the 2,3,4,5,6,7,8, and 9 keys. The 1 and 0 keys continue to place a 1 and 0 into the text field.
Display The touchscreen display is an active color LCD unit capable of supporting VGA graphics modes. Display size is 240 x 320 pixels in portrait orientation. The covering is designed to resist stains. The touchscreen allows signature capture and touch input.
Status LEDs The MX7 does not have a Bluetooth managed LED. Any Bluetooth activity indicators are located in the Desktop taskbar. System Status LED is located at the top left of the keypad, above the Scan button. The Scan Status LED is located below the keypad.
(e.g. AC adapter). The MX7 Cold Storage device is designed to operate normally when reading bar codes and moving from, and into, cold storage warehouses, freezers and vehicles where the temperatures may vary between -30°C and 5°C (-22°F and 41°F).
Cold Storage battery pack is inserted in the charging bay in a powered desk cradle. The battery pack temperature must be above 10°C (50°F) before re-charging can begin. Battery packs in the MX7 Tecton battery charger begin charging when the battery pack temperature is between 10°C (50°F) and +40°C (100°F).
Suspend Mode The Suspend mode is entered when the unit is inactive for a predetermined period of time or the user taps the Power key. MX7 Suspend timers are set using Start > Settings > Control Panel > Power > Schemes tab.
When the MX7 wakes up, the Display Backlight and the Power Off timers begin the countdown again. When any one of the above events occurs prior to the Power Off timer expiring, the timer starts the countdown again. The MX7 should be placed in Suspend mode before hotswapping the main battery.
A suspended MX7 maintains the date and time for a minimum of two days using a main battery that has reached the Low Warning point and a fully charged backup battery. The MX7 retains data, during a main battery hot swap, for at least 5 minutes.
The backup battery is a 50 mAh Nickel Cadmium (NiCd) battery that is factory installed in the unit. The energy needed to maintain the backup battery near full charge at all times is drawn from the MX7 main battery. It takes several hours of operation before the backup battery is capable of supporting the operation of the MX7.
Operating System and Software Load There are several different aspects to the setup, configuration and operation of the MX7. Many of the setup and configuration settings are dependent upon the optional features such as hardware and software installed on the unit. The examples found in this section are to be used as examples only, the configuration of your specific MX7 computer may vary.
General Windows CE Keyboard Shortcuts Use the keyboard shortcuts in the chart below to navigate with the MX7 keyboard. These are standard keyboard shortcuts for Windows CE applications. Press these keys … To … CTRL + C Copy CTRL + X...
A cold boot is initiated by running the Coldboot application in the Windows folder. This application automatically cold boots the MX7, erasing any customer applied registry changes and returning the MX7 to its factory settings. Clearing Persistent Storage / Reset to Default Settings The coldboot utility sets all registry settings back to factory defaults.
Start > Settings > Control Panel > Bluetooth Only installed on a Bluetooth equipped MX7. The System Administrator can Discover and Pair targeted Bluetooth devices for each MX7. The System Administrator can enable / disable Bluetooth settings and assign a Computer Friendly name for each MX7.
Click the My Device icon on the Desktop then click the System icon. A flash card is used for permanent storage of the MX7 drivers, CAB files and utilities. It is also used for registry content back CAB files, when executed, are not deleted.
MX7 Utilities The following files are pre-loaded. LAUNCH.EXE Launch works in coordination with registry settings to allow drivers or applications to be loaded automatically into DRAM at system startup. Registry settings control what gets launched; see the App Note for information on these settings. For...
The REG.TXT file is not saved in persistent storage. To use the REG.TXT file as a reference in the event of a coldboot, copy the file to the System folder on the MX7 or store a copy of the REG.TXT file...
WAVPLAY.EXE Double tapping a sound file (e.g. WAV) causes WavPlay to open the file and run it in the background. MX7 Command-line Utilities Command line utilities can be executed by Start > Run > [program name]. COLDBOOT.EXE Command line utility which performs a cold boot (all RAM is erased).
At a minimum, the desktop displays icons for My Device, Internet Explorer and the Recycle Bin. Following are a few of the other icons that may be on the MX7 Desktop. Please Contact your representative about the latest updates and upgrades for your operating system.
Start button. Access programs, select from the Favorites listing, documents last worked on, change/view settings for the control panel or taskbar, on-line help or run programs. Taskbar The number and type of icons displayed are based on the device type, installed options and configuration of the MX7. 4-10...
Related Manual: Using Wavelink Avalanche The MX7 has the Avalanche Enabler installation files loaded, but not installed, on the mobile device when it is shipped. The installation files are located in the System folder on CE devices. The installation application must be run manually the first time Avalanche is used.
The following list represents the factory default program installation. Your system may contain different items from those shown below, based on the software and hardware options purchased. Communication Stores Network communication options ActiveSync Transfer files between a MX7 and a desktop computer Connect Run this command after setting up a connection Start (or Stop) FTP...
ActiveSync is pre-loaded on all Windows mobile devices. Using Microsoft ActiveSync you can copy files from your MX7 to your desktop computer , and vice versa. Once an ActiveSync relationship (partnership) has been established with Connect (on a desktop computer), ActiveSync will synchronize using the wireless link, serial port, or USB on the MX7.
Command Prompt Start > Programs > Command Prompt Type help cmd at the command prompt to view valid Pocket PC (Console) commands. Exit the command prompt by typing exit at the command prompt or tap File > Close. 4-14...
There are few changes in the Windows CE version of Remote Desktop as it relates to the general desktop Windows PC Microsoft Remote Desktop options. If installed, Remote Desktop on the MX7 can be accessed by Start > Programs > Remote Desktop. Select a computer from the drop down list or enter a host name and tap the Connect button.
Settings Start > Settings The Settings menu option may include the following: Control Panel All control panels Shortcut to the Network and Dialup Connections control panel. Connect to a network, create a new Network connection, and adjust parameters for client connections. Taskbar Set Taskbar parameters Transcriber...
Taskbar Start > Settings > Taskbar There are a few changes in the Windows CE version of Taskbar as it relates to the general desktop PC Windows Taskbar options. When the taskbar is auto hidden, press the Ctrl key then the Esc key to make the Start button appear. Clicking the Taskbar option on the Settings menu displays theTaskbar General tab and the Taskbar...
Advanced Tab Expand Control Panel Tap the checkbox to have the Control Panel folders appear in drop down menu format from the Settings > Control Panel menu option. Clear Contents of Document Folder Tap the Clear button to remove the contents of the Document folder. 4-18...
Refer to Start > Help for an explanation of standard Windows CE taskbar icons. Following are a few of the MX7 and unique taskbar icons that may appear in the Taskbar. These icons are in addition to the Windows CE taskbar icons.
Maintain an uninterrupted AC/DC power source to the MX7 throughout this process. The SD / CF card with the OS and systems files must be present for the MX7 to boot. Removing or installing SD or CF cards should be performed on a clean, well-lit surface.
The operating system will not be able to execute the OS update when the battery level is too low (25% or less), as there is a high risk that the power remaining in the battery expires when executing the upgrade and the MX7 will be left in an inoperable state.
Change the font displayed on the touchscreen by choosing Start > Settings > Control Panel > Keyboard and then the Key map dropdown list. Tap the ? button for Help when changing MX7 Control Panel options. Contact your representative for updates as they become available.
Page 61
Option Function Password Set OS access password properties for signon and/or screen saver. Control the connection between the mobile device and a local desktop or laptop PC Connection computer. Power Set Power scheme properties. Review device status and properties. Set appearance of numbers, currency, time and date based on country region and Regional Settings language settings.
About Start > Settings > Control Panel > About The data cannot be edited by the MX7 user on these panels. Contents GUID, Windows CE Version, OAL Version, Bootloader Version, Compile Version, Software FPGA Version and Language. Language indicates any pre-installed Asian fonts.
The Versions tab displays the versions of many of the software programs installed. Not all installed software installed on the mobile device is included in this list and the list varies depending on the applications loaded on the MX7. The Image line displays the revision of the system software installed.
Accessibility Start > Settings > Control Panel > Accessibility Customize the way the MX7 keyboard, sound, display, mouse, automatic reset and notification sounds function. There are a few changes from general Windows desktop Accessibility options. Note: Honeywell disables the keypad StickyKeys and StickyKeys Settings on the Keyboard panel as this setting, when enabled, interferes with assigned sticky key implementation.
Page 65
Mouse Tab MouseKeys is disabled by default. Tap the Use MouseKeys checkbox to enable this option. Tap the Settings button to view or change parameters. General Tab Automatic reset is disabled by default. Tap the Turn off accessibility features checkbox to enable this option and use the dropdown option to assign a timer.
AppLock is designed to be run on Windows CE based devices only. Introduction Configuration parameters are specified by the AppLock Administrator for the MX7 end-user. AppLock is password protected by the Administrator. End-user mode locks the end-user into the configured application or applications. The end user can still reboot the mobile device and respond to dialog boxes.
Factory Default Settings - AppLock Application Panel Filename Blank Title Blank Arguments Blank Order Internet Disabled Global Key Ctrl+Spc Global Delay 10 sec Input Panel Disabled Launch Button Panel Auto at Boot Enabled Auto at Boot Retries Auto at Boot Delay 10 sec Auto Re-launch Enabled...
New devices with the AppLock feature are shipped to boot in Administration mode with no default password, thus when the MX7 is first booted, the user has full access to the device and no password prompt is displayed. After the administrator specifies the applications to lock, a password is assigned and the device is rebooted or the hotkey is pressed, the device switches to end-user mode.
Administration Mode Administration mode gives full access to the mobile device, hardware and software configuration options. The administrator must enter a valid password (when a password has already been assigned) before access to Administration mode and configuration options are allowed. The administrator can configure the following options: Create/change the keystroke sequence to activate administrator access.
End User Mode End-user mode locks the end-user into the configured application or applications. The end user can still reboot and respond to dialog boxes. Each application is automatically launched and runs in full screen mode when the device boots up. The user cannot unintentionally or intentionally exit the application nor can the end user execute any other applications.
Passwords A password must be configured. If the password is not configured, a new device switches into Administration mode without prompting for a password. In addition to the hotkey press, a mode switch occurs if inaccurate information has been configured or if mandatory information is missing in the configuration.
A checkmark indicates applications currently active or available for Launching by the user. When Keyboard is selected, the MX7 default input method (Input Panel, Transcriber, or custom input method) is activated. The check to the left of the application name indicates that the application is active.
Application Configuration Settings > Control Panel > Administration icon The default Administrator Hotkey sequence is Shift+Ctrl+A. Administrator mode allows access to all features on the device. When the hotkey is pressed to switch into Administrator mode, a password prompt is displayed (if a password has been configured). A password must be entered within 30 seconds (and within three tries) or the password prompt is removed and the device remains in end-user mode with the focus returned to the locked application.
Application Panel Note: Users of Single-Application AppLock have a Control tab instead of an Application tab. Some of the options in this section do not apply to the Control tab. Note: If your Application Panel does not look like the figure shown above, you may have the Single Application version.
Option Explanation Default is Ctrl+Spc. Select the Global Key key sequence the end-user is to press when switching between appli- Global cations. The Global Key default key sequence must be defined by the AppLock Administrator. The Global key is pre- sented to the end-user as the Activation key.
Auto At Boot Default is Enabled. Auto At Boot When enabled, automatically launches (subject to the specified Delay in seconds) the application after the unit is rebooted. If a Delay in seconds is specified, AppLock waits for the specified period of time to expire before launching the application. The Delay default value is 10 seconds;...
Auto Re-Launch Auto Re-Launch Default is Enabled. When enabled for a specific application. automatically re-launches it (subject to the specified Auto Re-Launch Delay in seconds) after it terminates. This option allows the Administrator to disable the re-launch operation. AppLock cannot prevent all applications from closing.
Manual (Launch) Default is Disabled. Enabling this option allows the end-user to launch the specified application(s). Upon bootup completion an application with Manual enabled is listed on the Switchpad accompanied by a checkmark that indicates the application is currently active or available for Launching. When an application name is tapped by the end-user, the application is launched (if inactive) and brought to the foreground.
Allow Close Default is Disabled. When enabled, the associated application can be closed by the end-user. This option allows the administrator to configure applications that consume system resources to be terminated if an error condition occurs or at the end-user’s request. Error conditions may generate a topmost popup requiring an end-user response, memory resource issues requiring an end-user response, etc.
Match Match Default is blank (match is not used). AppLock works by associating display windows with the launched process ID. If an application uses different process IDs for windows it creates, the Match field must be used. Use the Match field to specify up to 32 characters of the class name for the application. DOS applications using a standard DOS display box should specify condev_appcls in the Match textbox.
End User Internet Explorer (EUIE) AppLock supports applications that utilize Internet Explorer, such as .HTML pages and JAVA applications. The end user can run an application by entering the application name and path in Internet Explorer’s address bar. To prevent the end user from executing an application using this method, the address bar and Options settings dialog are restricted in Internet Explorer.
Security Panel Hotkey Specify the hotkey sequence that triggers AppLock to switch between administrator and user modes and the password required to enter Administrator mode. The default hotkey sequence is Shift+Ctrl+A. A 2 key keypress is an invalid keypress for a hotkey sequence. Move the cursor to the Hot Key text box.
Options Panel AppLock contains several types of delays and timeouts to accommodate different applications. Please note that the delays specified on the Launch panel are delays before AppLock attempts to start the specified application(s). The timeouts specified on this panel are delays after AppLock has attempted to launch the application. Launch timeout This timeout specifies the period of time for AppLock to wait for the application to initially launch after the application has been called.
Status Panel Use the Status panel to view the log of previous AppLock operations and to configure which messages are to be recorded during AppLock operation. Status information is stored in a specific location on the storage device and in a specific logfile specified by the Administrator. For this reason, the administrator can configure the type of status information that is logged, as well as clear the status information.
Note: If a level higher than Error is selected, the status should be cleared frequently by the administrator. In addition to the three view levels the administrator can select that all status information be logged or turn off all status information logging completely.
When the Administrator is selecting a hotkey sequence to use when switching user modes, they are not allowed to enter key combinations that are reserved by installed software applications. Honeywell has validated RFTerm key combinations ONLY. When RFTerm is installed on the mobile device and an RFTerm restricted key sequence is specified as a hotkey sequence by the Administrator, the following error message is displayed in a message box: Selected hotkey is not allowed.
AppLock Error Messages Any messages whose first word is an ‘ing’ word is output prior to the action described in the message. For example, “Switching to admin-hotkey press” is logged after the administrator has pressed the hotkey but prior to starting the switch process. For all operations that can result in an error, an Error level message is displayed when a failure occurs.
Page 88
Message Explanation and/or corrective action Level The load of the keyboard filter failed. This occurs when the dll is missing or is corrupted. Look in the \Windows directory for kbdhook.dll. If it exists, delete it. Also delete Cannot find kbdhook.dll LOG_ERROR AppLock.exe from the \Windows directory and reboot the unit.
Page 89
Message Explanation and/or corrective action Level Encrypt failure The password encryption failed. LOG_ERROR Encrypt gen key failure Unable to encrypt password. LOG_ERROR Encrypt generate key fail- Unable to encrypt password. LOG_ERROR Encrypt get user key fail- Unable to encrypt password. LOG_ERROR Encrypt get user key ok Encrypt password process successful.
Page 90
Message Explanation and/or corrective action Level Exit AppLock- There are two exit paths from the enumeration function. This message denotes the enu- LOG_PROC- EnumWindows-Not meration function did not find the application. ESSING found LOG_PROC- Exit DecryptPwd Exiting password decryption processing. ESSING LOG_PROC- Exit EncryptPwd...
Page 91
Message Explanation and/or corrective action Level Hook wndproc of open The application is open, but AppLock cannot lock it. LOG_ERROR app failure Hot key event creation The Admin applet is unable to create the hotkey notification. LOG_ERROR failure Hot key pressed Processing the hotkey and backdoor entry LOG_EX Hot key pressed...
Page 92
Message Explanation and/or corrective action Level Registering Backdoor The AppLock system communicates with the keyboard hook via a user defined message. LOG_PROC- Both AppLock.exe and Kbdhook.dll register the message at initialization. ESSING The AppLock system communicates with the keyboard hook via a user defined message. LOG_PROC- Registering Hotkey MSG Both Applock.exe and Kbdhook.dll register the message at initialization.
Page 93
Message Explanation and/or corrective action Level After the application is launched, AppLock must wait until the application has initialized Timeout looking for app itself before proceeding. The application did not start successfully and AppLock has timed LOG_ERROR window out. ToUser after admin, not The user mode switch is attempted when the device boots and after the administrator LOG_EX at boot...
Battery Start > Settings > Control Panel > Battery This panel is used to view the status and percentage of power remaining in the MX7 main battery. The data cannot be edited by the user. The battery gas gauge icon resides in the system tray and shows four levels of charge – 100%, 75%, 50%, 25%. At a point below 25%, the system status LED will turn red and the gas gauge icon will turn red indicating the battery is low.
Backup Battery Maintenance For best results, discharge and recharge the backup battery twice a year. Use the Charge or Discharge buttons to charge and discharge the backup battery: To Charge Tap the Charge button. The Discharge button text changes to “Off”. When the backup battery is charging, tap the Off button to stop the Charge process.
Bluetooth Start > Settings > Control Panel > Bluetooth Note: Contact your representative for upgrade availability if your Bluetooth control panel is not the same as the control panels presented in this section. Discover and manage pairing with nearby Bluetooth devices. Factory Default Settings Discovered Devices None...
It is not necessary to disconnect a paired scanner and printer before a different scanner or printer is paired with the MX7. The target Bluetooth device should be as close as possible (up to 32.8 ft (10 meters) Line of Sight) to the MX7 during the pairing process.
Note: When an active paired device enters Suspend Mode, is turned Off or leaves the MX7 Bluetooth scanning range, the Bluetooth connection between the paired device and the MX7 is lost. There may be audible or visual signals as paired devices disconnect from the MX7.
An icon with a red background indicates the device's Bluetooth connection is inactive. An icon with a white background indicates the device is connected to the MX7 and the device's Bluetooth connection is active. Double-tap a device in the list to open the device properties menu. The target device does not need to be active.
Stop the connection between the MX7 and the highlighted paired Bluetooth device. Remove an unpaired device from the Bluetooth device list. The highlighted device name and iden- Delete tifier is removed from the MX7 Bluetooth Devices panel after the user taps OK. Properties More information on the highlighted Bluetooth device.
Bluetooth Device Properties Data on the Bluetooth Properties panel cannot be changed by the user. The data displayed is the result of the device Query performed during the Discovery process. The Status dialog box reflects the current state of the highlighted device. 4-63...
Function This option is Enabled by default. Computer is connectable Disable this option to inhibit MX7 connection initiated by a Bluetooth scanner. This option is Disabled by default. Computer is discoverable Enable this option to ensure other devices can discover the MX7.
Page 103
(Filtered Mode is enabled/checked). Filtered Mode When Filtered Mode is disabled, the MX7 can pair with up to four Bluetooth devices, with a limit of one Bluetooth scanner, one Bluetooth printer, one PAN, and one DUN connected at the same time.
Reconnect Note: These options can still be checked or unchecked whether Bluetooth connection is enabled or disabled. Options Option Function This option is Enabled (checked) by default. There may be an audio or visual signal when a connection between a paired, active device is Report when connection lost.
Page 105
Option Function This option is Enabled (checked) by default. The default time delay is 30 minutes. This value cannot be changed by the user. There may be an audio or visual signal when a connection between a paired, active device fails to re-connect.
This is an alphanumeric field displaying the currently selected Outbox. The Outbox is the location where files are stored to be pushed from the MX7 to a remote server. Use the browse button ... to browse to and select the Outbox folder.
Page 107
Information When checked, the user is notified and may be prompted for a response when files are received by the MX7. When unchecked, inbound files are received with no notification to and no required Enable Notifications action from the user.
The most recently pushed file is highlighted, assuming that file is still present in the Outbox. Select OPP Server from This list displays the known OPP capable servers that the MX7 has previously discovered. Remote Device List The most recently paired server is selected and highlighted.
About This panel lists the assigned Computer Friendly Name (that other devices may discover during their Discovery and Query process), the Bluetooth MAC address, and software version levels. The data cannot be edited by the user. 4-71...
2. Tap the Settings Tab. 3. Change the Computer Friendly Name at the bottom of the Settings display. The Bluetooth MX7 default name is determined by the factory installed software version. Honeywell strongly urges assigning every MX7 a unique name (up to 32 characters) before Bluetooth Discovery is initiated.
LED on the device, or a dialog box is placed on the MX7 display. 14. Whenever the MX7 is turned On, all previously paired, live, Bluetooth devices in the vicinity are paired, one at a time, with the MX7.
MX7 is out of range of all paired Bluetooth device(s). Connection is inactive. Note: When an active paired device enters Suspend Mode, is turned Off or leaves the MX7 Bluetooth scan range, the Bluetooth connection between the paired device and the MX7 is lost. There may be audible or visual signals as paired devices disconnect from the MX7.
To open the LXEZ Pairing program, tap Start > Settings > Control Panel > Bluetooth or tap the Bluetooth icon on the desktop or tap the Bluetooth icon in the taskbar. Locate the bar code label, similar to the sample bar code shown above, attached to the MX7. The label is the Bluetooth address identifier for the MX7.
MX7 without Label If the MX7 Bluetooth address bar code label does not exist, follow these steps to create a unique Bluetooth address bar code for the MX7: First, locate the MX7 Bluetooth address by tapping Start > Settings > Control Panel > Bluetooth > About tab.
Bluetooth Printer Setup The Bluetooth managed device should be as close as possible, in direct line of sight, with the MX7 during the pairing process. 1. Open the LXEZ Pairing Panel. 2. Tap Discover. Locate the Bluetooth printer in the Discovery panel.
If a duplicate filename is received, LXEZ Pairing writes the file in the specified location, with an incremental number appended to the file name. For example, if a file named file.jpg is pushed to the MX7 and that filename already exists in the Inbox, LXEZ Pairing saves the new file as file001.jpg.
This section assumes that a device supporting OPP is paired with the MX7. The MX7 (OPP client) initiates a connection to the remote device (OPP server) by selecting a file to push to the remote device. The MX7 sends the file and disconnects. The remote device may prompt the user (of that remote device) to accept the incoming request depending on the security settings of the remote device.
Start > Settings > Control Panel > Certificates Manage digital certificates used for secure communication. Note: Digital certificates are date sensitive. If the date on the MX7 is incorrect, wireless authentication will fail. The Certificates stores lists the certificates trusted by the MX7 mobile device user.
Date / Time Start > Settings > Control Panel > Date/Time - or - Time in Desktop Taskbar Use this MX7 panel to set Date, Time, Time Zone, and assign a Daylight Savings location. Factory Default Settings Current Time Midnight...
Device Management Start > Settings > Control Panel > Device Management Allows a Device Management client (the device equipped with a Microsoft Windows CE operating system) to work with a Microsoft Systems Management Server. Specify the server name or IP address of management server and check the checkbox if a secure connection is to be used. Refer to the Microsoft.com website for more information on device management for Windows CE equipped devices.
Dialing Start > Settings > Control Panel > Dialing Set dialup properties for internal modems (not supplied or supported on the MX7). Factory Default Settings Location Work Area Code Tone Dialing Enabled Country/Region Disable Call Waiting Disabled (blank) 4-83...
The display might also called the touchscreen. Select the desktop background image and appearance scheme for the MX7. Using the options on the Backlight tab, set the display backlight and keypad backlight timers when running on battery or external power.
Appearance There is very little change from general desktop PC Appearance options. Select a scheme from the dropdown list and make changes to the parameters. The default is High Contrast White for monochrome displays and Windows Standard for color displays. Tap the Save button to save any changes, renaming the scheme if desired. Tap the Delete button to delete schemes. Tap the Apply button to apply the selected scheme to the display.
Backlight The backlight settings use the factory default timeouts and is synchronized to the User Idle setting in the Schemes tab in the Power control panel. When the backlight timer expires, the touchscreen backlight is dimmed, not turned off. When both checkboxes are unchecked, the backlight never turns off (or dims).
Input Panel Start > Settings > Control Panel > Input Panel Set the current MX7 keys and data input method. Factory Default Settings Input Method Keyboard Allow applications to change Enabled input panel state Options button Keys Small keys Use gestures...
Installed Programs Start > Settings > Control Panel > Installed Programs Note: Lists programs installed in RAM. View the list of installed programs. No user interaction is required or allowed. In some OS versions, this panel replaces Remove Programs. Note: Contact your representative for assistance if pre-installed programs must be deleted.
Internet Options Start > Settings > Control Panel > Internet Options Set options for MX7 Internet connectivity. Select a tab. Tap the ? button for help using Windows CE Help installed in your mobile device. Adjust the settings and tap the OK button.
Page 128
Note: Security Tab: Use the Settings button to set ActiveX control, scripting and plug-in behavior for each zone (Internet, Local intranet, Trusted Sites, Restricted Sites). Use the Site button to add sites to each zone. 4-90...
Backlight Start > Settings > Control Panel > Keyboard > Backlight Tap the radio button to set the keypad backlight always on, always off or to follow the display. When the keypad backlight is set to follow the display, the keypad backlight turns on when the display backlight turns on and turns off when the display backlight turns off.
KeyPad Start > Settings > Control Panel > KeyPad Icon Use this control panel option to assign key functions to mappable keys available on your MX7, determine application launch sequences and program command Run sequences. Note: KeyPad Control Panel options LaunchApp and RunCmd do not inter-relate with similarly-named options contained in other Control Panel applets.
KeyMap Tab 55 Key Keypad 32 Key Keypad Assign settings by clicking radio buttons and selecting keys from the drop down boxes. Tap the OK button when finished. The changes take effect immediately. How to Remap a Single Key 1. Select the modifier key from the Modifier Mode options. 2.
Page 134
How to Remap an Application 1. Select the modifier key from the Modifier Mode options. 2. Select the key to be remapped from the Key pulldown list. 3. Select Launch App1-4 from the remapped key from the Remapped Key pulldown list. 4.
The default for all text boxes is Null or “ ”. The text boxes accept string values only. Note that executables and parameters are not checked for accuracy by the keyboard driver. If the launch fails, the MX7 emits a single beep, if the launch is successful, it is silent.
The default for all text boxes is Empty, Null or " ". The text boxes accept string values only. Note that executables and parameters are not checked for accuracy by the keyboard driver. If the launch fails, the MX7 emits a single beep, if the launch is successful, the mobile device is silent.
License Viewer Start > Settings > Control Panel > License Viewer Use this option to view software license registration details, and service contract length for a MX7. Information on the License Viewer tabs is unique for each MX7. Note: Following image is a sample screen.
Start > Settings > Control Panel > Mixer The MX7 has a speaker. It is active when a headset is not connected to the device. Use the settings on these panels to adjust the volume, record gain and sidetone for microphone input, speaker and speaker output.
Input Panel Input Boost - When checked (enabled) increases the sensitivity of the microphone by 20 dB. How To . . . Enable Microphone -- Enable the Mic radio button and the Input Boost checkbox. Disable Microphone -- Enable the None radio button. 4-101...
Set options such as IP V6, time sync, touchscreen enable and CapsLock. Also set Status Popup taskbar icon display options for the Admin and User. It may be necessary to warmboot the MX7 after making desired changes. A pop up window indicates if a warmboot is required. Note: If there is no icon corresponding to this item in the Control Panel, contact your Honeywell...
Autolaunch TimeSync By default, TimeSync does not automatically run on the MX7. To enable TimeSync to run automatically on the MX7, check this checkbox. Synchronize with a Local Time Server By default, GrabTime synchronizes via an Internet connection. To synchronize with a local time server: 1.
MX7 heating elements activate when ambient temperature drops below 0°C (32°F). When performing screen touch functions at these temperatures, it is recommended to use the stylus.. There may be some condensation as the MX7 moves in and out of cold storage areas. The condensation on the touchscreen and the scan aperture quickly dissipates.
Main Battery Low Warn Dialog Enable Enable or disable the main battery low warning message. The default is unchecked (disabled). When the message is displayed, it must be manually dismissed by the user. Note: The backup battery low warning message must be enabled first in order to enable the main battery low warning message.
Status Popup Start > Settings > Control Panel > MX7II Options Options on this tab configure the Status Popup window. When the Status popup window is displayed, it is placed on top of the window in focus and hides any data beneath it. It is closed by pressing the assigned Status User or Status Admin key. Using the KeyPad control panel, the System Administrator must first assign a Status User key sequence for the end-user when they want to toggle the Status Popup Window on or off.
Touch Screen The options on this screen can be used to reduce the CPU consumption of the MX7. Bulk Samples Bulk Samples is the number of touch screen samples taken per cycle, with high and low values discarded. The default is 8.
Network and Dialup Options Start > Settings > Control Panel > Network and Dialup Connections Set MX7 network driver properties and network access properties. Select a connection to use, or create a new connection. Create a New Connection 1. On the mobile device, select Start > Settings > Control Panel > Network and Dialup Connections. A window is displayed showing the existing connections.
Network Capture Start > Settings > Control Panel > Network Capture Note: Verify the date and time before using the logging utilities to ensure meaningful data. The Network Capture panels provide configuration options for logging utilities. Two types of logging are configurable: Netlog is a Windows CE utility that monitors network traffic.
Page 149
Command Function options Specifies the option to perform. See the table below for the option parameters and values. load Loads and starts Netlog. start Starts the Netlog process of logging the network traffic. stop Stops Netlog from logging network traffic. unload Unloads Netlog.
NDISLog NDISLog creates a .TXT file that can be viewed with any text editor program that supports .TXT files. Command Function start Starts logging the network traffic. stop Stops logging network traffic. file Specifies the name of the file to which NDISLog information is stored. Save File Stores the file name.
Owner Start > Settings > Control Panel > Owner Set the MX7 owner details. The Network ID is used when logging into a remote network. Factory Default Settings Identification Name Blank Company Blank Address Blank Telephones Blank Display owner ID at power-on...
Page 152
Enter user name, password and domain to be used when logging into network resources. 4-114...
Start > Settings > Control Panel > Password Use this panel to set MX7 user access to control panels and power up password properties. Important: This password must be entered before performing a cold boot or cold reset. Contact your...
PC Connection Start > Settings > Control Panel > PC Connection Use these options to control a cabled connection (USB, serial) between the MX7 and a nearby desktop/laptop computer. Factory Default Settings Enable direct connection Enabled Connect using USB Client Unchecking the Enable direct connections checkbox disables ActiveSync on the MX7.
Power Start > Settings > Control Panel > Power The MX7 power mode timers are cumulative. The System Idle timer begins the countdown after the User Idle timer has expired and the Suspend timer begins the countdown after the System Idle timer has expired.
Page 156
Because of the cumulative effect, and using the Battery Power Scheme Defaults listed above: The backlight turns off after 3 seconds of no activity, The display turns off after 18 seconds of no activity (15 sec + 3 sec), And the device enters Suspend after 5 minutes and 18 seconds of no activity. If the User Idle timer is set to Never, the power scheme timers never place the device in User Idle, System Idle or Suspend modes.
Regional and Language Settings Start > Settings > Control Panel > Regional Settings Set the appearance of numbers, currency, time and date based on regional and language settings. Set the MX7 user interface language and the default input language. Factory Default Settings...
The Installed Programs panel does not allow any user interaction. Select a program and tap Remove. Follow the prompts on the screen to uninstall MX7 user-installed only programs. The change takes effect immediately. Files stored in the My Documents folder are not removed using this option.
When using any bar code reader to scan the Reset All (or equivalent) bar code (available in the Integrated Scanner Programming Guide) with the MX7 integrated scan engine, the next step is to open the Scanner Control Panel, click the OK button and then close it.
The MX7 can use the following external bar code readers: Tethered hand-held scanners are tethered to a serial port on the MX7 or cradle/dock and are configured by scanning the engine-specific bar codes in the scanner manufacturer's programming guide. The manufacturer's guides are usually shipped with the bar code reader.
Bar Code Processing Overview Bar code processing involves several steps. Some steps may be skipped during the processing depending on user selections on the Scanner control panels. The steps are presented below in the order they are performed on the bar code data. 1.
Rejected bar codes generate a bad scan beep. In some cases, the receipt of data from the scanner triggers a good scan beep from an external scanner, and then the rejection of scanned bar code data by the processing causes a bad scan beep from the MX7 on the same data.
Page 165
Click here to view factory default settings for this panel. 4-127...
COM1 Tab Start > Settings > Control Panel > Scanner > COM1 This panel sets communication parameters for any device connected to the external port. Adjust the settings and click the OK button to save the changes. Any changes take effect immediately. This panel does not configure the connected device.
Barcode Tab Start > Settings > Control Panel > Scanner > Barcode tab The Barcode tab contains several options to control bar code processing. Options include: Defining custom Code IDs Disable processing of specified bar code symbologies Rejecting bar code data that is too short or too long Stripping characters including Code ID, leading or trailing characters and specified bar code data strings Replacing control characters Adding a prefix and a suffix.
Buttons Individually enable or disable a bar code from being scanned, set the mini- mum and maximum size bar code to accept, strip Code ID, strip data from Symbology Settings the beginning or end of a bar code, or (based on configurable Barcode Data) add a prefix or suffix to a bar code before transmission.
Continuous Scan Mode Start > Settings > Control Panel > Scanner > Barcode Tab Enabling Continuous Scan Mode will ensure the laser is always on and decoding. Caution: Laser beam is emitted continuously. Do not stare into the laser beam. Set the Timeout between same symbol to a value sufficient to prevent the beeper from continuously beeping when a symbol is left in the scanner’s field of view.
Enable Code ID This parameter programs the scanner to transmit the specified Code ID and/or determines the type of bar code identifier being processed. Transmission of the Code ID is enabled at the scanner for all bar code symbologies, not for an individual symbology. Code ID is sent from the scanner so the scanner driver can discriminate between symbologies.
Page 171
Notes When Strip: Code ID (see Symbology panel) is not enabled, the code ID is sent as part of the bar code data to an application. When Strip: Code ID (see Symbology panel) is enabled, the entire Code ID string is stripped (i.e. treated as a Code ID). UPC/EAN Codes only: The code id for supplemental bar codes is not stripped.
Bar Code – Custom Identifiers Code IDs can be defined by the user. This allows processing parameters to be configured for bar codes that do not use the standard AIM or Symbol IDs or for bar codes that have data embedded at the beginning of the data that acts like a Code ID. These are called custom Code IDs and are included in the Symbology drop down box in the Symbology dialog, unless Enable Code ID is set to None.
Parameters Name text box Name is the descriptor that is used to identify the custom Code ID. Names must be unique from each other; however, the Name and ID Code may have the same value. Name is used in the Symbology drop down box to identify the custom Code ID in a user-friendly manner.
Control Code Replacement Examples Configuration Example Con- Example Con- Translation Translated Data Data trol Character figuration The control character is discarded from 0x1B in the bar code is dis- Ignore (drop) ESCape Ignore (drop) the bar code data, prefix and suffix carded.
Bar Code Processing Examples The following table shows examples of stripping and prefix/suffix configurations. The examples assume that the scanner is configured to transmit an AIM identifier. Symbology EAN-128(]C1) EAN-13(]E0) Intrlv 2 of 5(]IO) Code93 Enable Enabled Enabled Enabled Enabled Disabled Min length Max length...
Bar Code - Ctrl Char Mapping The Ctrl Char Mapping button (Control Character Mapping) activates a dialog to define the operations the Wedge performs on control characters (values less than 0x20) embedded in bar codes. Control characters can be replaced with user-defined text which can include hat encoded or hex encoded values.
Page 177
Character This is a drop down combo box that contains the control character name. Refer to the Character drop down box for the list of control characters and their names. When a character name is selected from the drop down box, the default text Ignore (drop) is shown and highlighted in the Replacement edit control.
Barcode Data) add a prefix or suffix to a bar code. The Symbology drop-down box contains all symbologies supported on the MX7. An asterisk appears in front of symbologies that have already been configured or have been modified from the default value.
Note: In Custom mode on the Barcode tab, any Code IDs not specified by the user will not be stripped, because they will not be recognized as Code IDs. If a specific symbology's settings have been configured, a star (*) will appear next to it in the Symbology drop-down box, so the user can tell which symbologies have been modified from their defaults.
Strip Leading/Trailing Control This group of controls determines what data is removed from the bar code before the data is buffered for the application. When all values are set, Code ID takes precedence over Leading and Trailing; Barcode Data stripping is performed last. Stripping occurs before the Prefix and Suffix are added, so does not affect them.
Barcode Data Match List Barcode Data Panel This panel is used to strip data that matches the entry in the Match list from the bar code. Enter the data to be stripped in the text box and tap the Insert or Add button. The entry is added to the Match list. To remove an entry from the Match list, highlight the entry in the list and tap the Remove button.
Match List Rules The data in the match list is processed by the rules listed below: Strings in the list will be searched in the order they appear in the list. If the list contains ABC and AB, in that order, incoming data with ABC will match first, and the AB will have no effect.
Add Prefix/Suffix Control Use this option to specify a string of text, hex values or hat encoded values to be added to the beginning (prefix) or the end (suffix) of the bar code data. Up to 19 characters can be included in the string. The string can include any character from the keyboard plus characters specified by hex equivalent or entering in hat encoding.
Length Based Bar Code Stripping Use this procedure to create symbology rules for two bar codes with the same symbology but with different discrete lengths. This procedure is not applicable for bar codes with variable lengths (falling between a maximum value and a minimum value). Example 1: A normal AIM or Symbol symbology role can be created for the desired bar code ID.
Page 185
c3 min length = 24, max length = 24, strip leading 2, strip trailing 8, Code ID enabled, Barcode Data = “01” c4 min length = 20, max length = 20, strip leading 0, strip trailing 4, Code ID enabled, Barcode Data = “00” Add the AIM custom symbologies.
Vibration Tab Start > Settings > Control Panel > Scanner > Vibration Vibration is activated when the trigger on the trigger handle is pressed or either Scan button is pressed. The default setting for both Good Scan and Bad Scan vibration is Off. Enable this parameter when a tactile response on a good scan or bad scan is desired.
Stylus Start > Settings > Control Panel > Stylus Use this control panel option to set stylus double-tap sensitivity properties and calibrate the MX7 touch panel when needed. Double Tap Follow the instructions on the screen and tap the OK button to save any double tap changes.
System Start > Settings > Control Panel > System Use these MX7 panels to: Review System and mobile device data and revision levels. Adjust Storage and Program memory settings. Assign a device name and device descriptor. Factory Default Settings General...
The device name and description can be changed by the user. Enter the name and description using either the keypad or the Input Panel and tap OK to save the changes. This information is used to identify the MX7 to other computers and devices.
Terminal Server Client Licenses Start > Settings > Control Panel > Terminal Server Client Licenses Any licenses stored on the MX7 appear in the drop-down list. Select a license and tap the Close button. The license is available for use immediately.
You can also select / deselect sounds for key clicks and screen taps and whether each is loud or soft. As the volume scrollbar is moved between Loud and Soft, the MX7 emits a tone each time the volume increases or decreases.
WAV files and can be replaced by a WAV file of the user’s choice. By default a good scan sound on the MX7 is a single beep, and a bad scan sound is a double beep. WiFi Control Panel Start >...
Windows Mobile Device Center. Using Microsoft ActiveSync you can synchronize information on your desktop computer with the MX7 and vice versa. Synchronization compares the data on your mobile device with your desktop computer and updates both with the most recent data.
USB cable is connected, not requiring you to select “Connect” from the start menu. Cable for USB ActiveSync Connection: MX7052CABLE - MX7 Charge/Comm Interface Cable with USB Client port for ActiveSync. USB end of cable connects to PC/Laptop USB port.
MX7055CABLE - MX7 Charge/Comm Interface Cable with serial connector to connect to PC/Laptop serial port. Connect the MX7 end of the cable to the I/O connector on the bottom of the MX7. Connect the serial port cable end to a COM port on a PC or laptop.
Synchronizing from the Mobile Device To synchronize using a wireless LAN card, you must have set up ActiveSync on your desktop computer and completed the first synchronization process before you initiate synchronization from your device. To initiate synchronization from your device, tap Start > Programs > Communication > ActiveSync to begin the process. Tap Sync to connect and synchronize.
Tap the status bar icon in the lower right hand corner of the status bar. Then tap the Disconnect button. IMPORTANT – Do not put the MX7 into Suspend while connected via USB. The device will be unable to connect to the host PC when it resumes operation.
If the MX7 is connected to a PC by a cable, disconnect the cable from the MX7 and reconnect it again. Check that the correct connection is selected (Serial or USB “Client” if this is the initial ActiveSync installation).
MX7 and the PC. If The MX7 uses a serial port for ActiveSync, it is necessary to configure the MX7 to use the serial port. Complete details on the proper cables and port configuration are included in the ActiveSync section.
Page 204
7. Select and copy the LXEConnect.msi and Setup.exe files from the MX7 to the user PC. Note the location chosen for files 8. Close the ActiveSync explorer dialog box. Do not disconnect the MX7 ActiveSync connection. 9. Execute the setup.exe file that was copied to the user PC. This setup program installs the LXEConnect utility.
LXEConnect window on the PC desktop. The dialog box automatically times out and disappears after approximately 30 seconds. 5. The MX7 can now be configured from the LXEConnect window. Input from the PC’s mouse and keyboard are recognized as if they were attached to the MX7.
Chapter 6: Enabler Installation and Configuration Introduction This section discusses Honeywell supported features with Wavelink Avalanche Mobile Device Servers. This section is split into three basic areas: Installation User Interface Enabler Configuration Installation To use the Wavelink Avalanche MC System, the following items are required: A desktop or laptop PC on which to install the Avalanche MC Console.
The Avalanche folder cannot be deleted while the Enabler is running. See Stop the Enabler Service. If sharing errors occur while attempting to delete the Avalanche folder, warm boot the MX7, immediately delete the Avalanche folder, and then perform another warm boot. Stop the Enabler Service To stop the Enabler from monitoring for updates from the Mobility Center Console: 1.
Update Monitoring Overview There are three methods by which the Enabler on the MX7 can communicate with the Mobile Device Server running on the host machine. Wired via a serial cable between the Mobile Device Server PC and the MX7.
Mobile Device Wireless and Network Settings Once the connection to the Mobile Device Server is established, the MX7 Enabler attempts to apply all network and wireless settings contained in the active profile. The success of the application of settings is dependent upon the local configuration of control parameters for the Enabler.
This utility is downloaded and installed in addition to the Remote Management Utility. The WCA is included when the Summit radio driver software is updated. The WCA is automatically installed when the radio driver is updated. If the Remote Management Utility (RMU) is not present on the MX7, see Using Wavelink...
RMU. Version Information The VersionInfo.EXE file is included in the Remote Management Utility package downloaded to the MX7. It is stored in the \Program Files\RMU folder. When VersionInfo.EXE is opened, a dialog box is presented to the MX7 user displaying:...
User Interface The Enabler can be configured and controlled manually through the user interface on the MX7. This section details the functionality that can be controlled by the user or system administrator. Parameters and Screen Displays Screen displays shown in this section are designed to present the end-user with information graphically.
Enabler Configuration Depending on the version of the Enabler running on the MX7 the desktop Enabler icon may look like one of the following: The available configuration options and tabs may vary by Enabler version. The examples shown in this section assume the latest version of the Enabler is installed on the MX7.
Refer to the Wavelink Avalanche Mobility Center User Guide for details. The Settings option under the File menu allows the MX7 user to access the control panel to locally configure the Enabler settings. The Enabler control panel is, by default, password protected.
Avalanche Update using File > Settings Use these menu options to setup the Avalanche Enabler on the MX7. Always change settings and then save the changes (reboot) before connecting to the network. Alternatively, the Mobile Device Server can be disabled until needed (refer to the Wavelink Avalanche Mobility Center User’s Guide for details).
Connection Avalanche Enter the IP Address or host name of the Mobile Device Server assigned to the MX7. Server Address Check Serial Indicates whether the Enabler should first check for serial port connection to the Mobile Device Server Connection before checking for a wireless connection to the Mobile Device Server.
Sync Clock Reset the time on the MX7 based on the time on the Mobile Device Server host PC. On Startup – Connect to the Mobile Device Server when the Enabler is accessed. On Resume – Connect to the Mobile Device Server when resuming from Suspend mode.
Data The Data tab controls when data is transferred between the MX7 and the Mobile Device Server. Real-time Statistics / When checked, the statistics are transmitted over the network by the Enabler. Network Specifies the Report Interval, how frequently the Enabler reports statistics to the Mobile Device Report Server.
By default, Keep settings unlocked for 10 minutes is disabled (checkbox is blank). Application Behavior of the Enabler when the MX7 boots up. The default is Monitor for Updates. Do not Monitor - When the device boots, do not launch the Enabler application and do not attempt to connect to the Mobile Device Server.
Page 221
Activity Log Use this option to control the level of detail recorded in the log file. The default is No Activity Log. No Activity Log - No log file is written. Critical - Only critical errors written to the log files. Error - Communication or configuration problems are written to the log file along with critical Log Level messages.
Display Update Window Display The user interface for the Enabler can be configured to dynamically change based on the status of the MX7 connection with the Mobile Device Server. At startup Default is Half Screen. Options are Half screen, Hidden or Full screen.
Taskbar For best results use AppLock to manage the taskbar. AppLock is resident on each mobile device with a Windows OS. If the Taskbar tab is not present on the Enabler installed on your device, please see the equivalent options on the Startup/Shutdown tab.
Execution Note the dimmed options on this MX7 panel. This menu option is designed to manage downloaded applications for automatic execution upon startup. Auto-Execute An application that has been installed with the Avalanche Management system can be run Selection automatically following each boot.
Scan Config For best results use eXpress Config and eXpress Scan for this function. eXpress Scan is included with the updated MX7 enablers. Scan Config functionality is a standard option of the Wavelink Avalanche MC system but is not currently supported on the MX7.
For best results use AppLock for this function. AppLock is resident on each mobile device with a Windows OS. Configure shortcuts to other applications on the MX7. Shortcuts are viewed and activated in the Programs panel. This limits the user’s access to certain applications when the Enabler is controlling the mobile device display.
SaaS Use to configure the Enabler to connect with Avalanche on Demand. This is a Software-as-a-Service version of Avalanche. Using either of the SaaS configuration options below assumes the user has registered with Wavelink. Disable SaaS No SaaS connection is used. Scan Configure Scan bar codes printed from within the Avalanche Console to configure the Enabler for the SaaS con- SaaS...
Settings should not be checked as Summit configuration packages provide more radio configuration options. Current Lists all network adapters currently installed on the MX7. Adapter Primary Indicates if the Enabler is to attempt to configure the primary adapter (active only if there are multiple network Adapter adapters).
Page 229
When enabled, the Enabler will ignore any network or wireless settings coming from the Avalanche MC Settings Console and use only the network settings on the MX7. Properties Selecting the Properties icon displays the Manual Settings Properties dialog applet. From here, the user can...
Page 230
Note: The Authentication tab may not be present in all versions of the Enabler. Do not enable “Manage Wireless Settings” for Summit Client devices. Note: When you download a profile that is configured to manage network and wireless settings, the Enabler will not apply the manage network and wireless settings to the adapter unless the global Manage wireless settings and Manage network settings options are enabled on the Adapters panel.
It also searches for new adapters and may cause a slight delay to refresh the contents of the drop-down menu. Link speed indicates the speed at which the signal is being sent from the adapter to the MX7. Speed is dependent on signal strength.
Startup/Shutdown For best results use AppLock to manage the taskbar. AppLock is resident on each mobile device with a Windows OS. If the Startup/Shutdown tab is not present on the Enabler installed on your device, please see the equivalent options on the Preferences tab and the Taskbar...
Exit The Exit option is password protected. The default password is leave. The password is not case-sensitive. If changes were made on the MX7 Startup/Shutdown tab screen, then after entering the password, tap OK and the following screen is displayed: Change the option if desired.
Using Remote Management 1. Configure the radio to connect to the network running the Mobile Device Server. After the MX7 is connected, proceed to step 2. 2. If it is desired to configure the radio using the Summit package, add the configured package to the Wavelink Avalanche MC Console and enable it.
Using eXpress Scan eXpress Scan Desktop Icon If the MX7 has an eXpress Scan icon on the desktop, eXpress Scan may be used for the initial configuration of the device. If the eXpress Scan icon is not present on the desktop, install the Enabler. If the icon is still not present,...
Page 236
If the passwords match, the bar code data is processed and the screen is updated to reflect the number of bar codes included in the set. If the passwords do not match, an error message is displayed. The current screen can be closed using the X box in the upper right corner.
Step 3: Process Completion After the last bar code is scanned, the settings are automatically applied. Once configured, the MX7 is warmbooted. Once connected to the wireless network and the Mobile Device Server, any software updates and additional configuration data are downloaded.
Utility. Important Notes It is important that all dates are correct on the MX7 and host computers when using any type of certificate. Cer- tificates are date sensitive and if the date is not correct authentication will fail. It may be necessary to upgrade radio software in order to use certain Summit Client Utility (SCU) features.
Summit Client Utility Note: When making changes to profile or global parameters, the device should be warmbooted afterwards. Access: Start | Programs | Summit | SCU or SCU Icon on Desktop or Summit Tray Icon (if present) or Wi-FI Icon in the Windows Control Panel (if present) Main Tab provides information, admin login and active profile selection.
Summit Tray Icon The Summit tray icon provides access to the SCU and is a visual indicator of radio status. The Summit tray icon is displayed when: The Summit radio is installed and active The Windows Zero Config utility is not active The Tray Icon setting is On Click the icon to launch the SCU.
Main Tab Start > Programs > Summit > Main tab Factory Default Settings Admin Login SUMMIT Radio Enabled Active Config/Profile Default Regulatory Domain FCC or ETSI The Main tab displays information about the wireless client device including: SCU (Summit Client Utility) version Driver version Radio Type (BG is an 802.11 b/g radio, ABG is an 802.11 a/b/g radio).
The Disable Radio button can be used to disable the network card. Once disabled, the button label changes to Enable Radio. By default the radio is enabled. The Admin Login button provides access to editing wireless parameters. Profile and Global may only be edited after entering the Admin Login password.
Admin Login To login to Administrator mode, tap the Admin Login button. Once logged in, the button label changes to Admin Logout. The admin is automatically logged out when the SCU is exited. The Admin can either tap the Admin Logout button, or the OK button to logout. The Administrator remains logged in when the SCU is not closed and a Suspend/Resume function is performed.
Profile Tab Start | Programs | Summit | Profile tab Note: Tap the Commit button to save changes before leaving this panel or the SCU. If the panel is exited before tapping the Commit button, changes are not saved! Factory Default Settings Profile Default SSID...
Buttons Button Function Commit Saves the profile settings made on this screen. Settings are saved in the profile. Allows entry of a username and password, certificate names, and other information required to authenticate with Credentials the access point. The information required depends on the EAP type. Deletes the profile.
Options are: None, WEP (or Manual WEP), WEP EAP (or Auto WEP), WPA PSK, WPA TKIP, WPA CCKM, WPA2 PSK, WPA2 AES, or WPA2 CCKM. Encryption None CKIP is not supported in the MX7. Note: The Encryption type chosen determines if the WEP Keys / PSK Keys button is active and also determines the available entries in the WEP or PSK pop-up window.
Page 248
It is important the Radio Mode parameter correspond to the AP to which the device is to connect. For example, if this parameter is set to G rates only, the MX7 may only connect to APs set for G rates and not those set for B and G rates.
Status Tab Start | Programs | Summit | Status tab This screen provides information on the radio: The profile being used The status of the radio card (down, associated, authenticated, etc.) Client information including device name, IP address and MAC address. Information about the Access Point (AP) maintaining the connection to the network including AP name, IP address and MAC address.
Diags Tab Start > Programs > Summit > Diags tab The Diags screen can be used for troubleshooting network traffic and radio connectivity issues. (Re)connect – Use this button to apply (or reapply) the current profile and attempt to associate or authenticate to the wireless LAN.
Global Tab Start > Programs > Summit > Global tab The parameters on this panel can only be changed when an Admin is logged in with a password. The current values for the parameters can be viewed by the general user without requiring a password. Note: Tap the Commit button to save changes.
Custom Parameter Option Honeywell does not support the parameter Custom option. The parameter value is displayed as “Custom” when the operating system registry has been edited to set the Summit parameter to a value that is not available from the parameter’s drop down list.
Global Parameters Parameter Default Function If signal strength is less than this trigger value, the client looks for a different Access Point with a stronger signal. Roam -65 dBm Trigger Options are: -50 dBm, -55, -60, -65, -70, -75, -80, -85, -90 dBm or Custom. Note: Available options may vary by SCU revision.
Page 254
The options for the TX Diversity parameter should be set, based on the antenna configuration, as follows: Antenna Configuration TX Diversity A Main and BG Main Main Only A Main and A Aux BG Main and BG Aux Contact your representative if you have questions about the antenna(s) installed on your MX7. 7-16...
Page 255
BG Main and BG Aux On-start on Main Contact your representative if you have questions about the antenna(s) installed on your MX7. Parameter Default Function If the packet size (in bytes) exceeds the specified number of bytes set in the fragment threshold, the packet is fragmented (sent as several pieces instead of as one block).
Page 256
Parameter Default Function A valid directory path, of up to 64 characters, where WPA Certificate Authority and User Certificates are stored on the mobile device when not using the Windows certifcates store. Make sure the Windows folder path currently exists before assigning the path in this parameter. See Certificates instructions on obtaining CA and User Certificates.
Sign-On vs. Stored Credentials When using wireless security that requires a user name and password to be entered, the Summit Client Utility offers these choices: The Username and Password may be entered on the Credentials screen. If this method is selected, anyone using the device can access the network.
How to: Use Sign On Screen 1. After completing the other entries in the profile, click on the Credentials button. Leave the Username and Password blank. No entries are necessary on the Credentials screen for LEAP or LEAP/WPA. 2. For PEAP-MSCHAP and PEAP-GTC, importing the CA certificate into the Windows certificate store is optional. 3.
Windows Certificate Store vs. Certs Path Note: It is important that all dates are correct on the MX7 and host computers when using any type of certificate. Certificates are date sensitive and if the date is not correct authentication will fail.
Page 260
How To: Use Windows Certificate Store 1. See Generating a Root CA Certificate and follow the instructions to download the Root Certifcate to a PC. 2. To import the certificate into the Windows store, See Installing a Root CA Certificate. 3.
Configuring the Profile Use the instructions in this section to complete the entries on the Profile tab according to the type of wireless security used by your network. The instructions that follow are the minimum required to successfully connect to a network. Your system may require more parameters than are listed in these instructions.
To connect using WEP, make sure the following profile options are used. Enter the SSID of the Access Point assigned to this profile Set EAP Type to None Set Encryption to WEP or Manual WEP (depending on SCU version) Set Auth Type to Open 7-24...
Page 263
Click the WEP keys/PSKs button. Valid keys are 10 hexadecimal or 5 ASCII characters (for 40-bit encryption) or 26 hexadecimal or 13 ASCII characters (for 128- bit encryption). Enter the key(s) and click OK. Once configured, click the Commit button. Ensure the correct Active Profile is selected on the Main tab and warmboot.
LEAP To use LEAP (without WPA), make sure the following profile options are used. Enter the SSID of the Access Point assigned to this profile Set EAP Type to LEAP Set Encryption to WEP EAP or Auto WEP (depending on SCU version) Set Auth Type as follows: If the Cisco/CCX certified AP is configured for open authentication, set the Auth Type radio parameter to Open.
Page 265
To use Stored Credentials, click on the Credentials button. No entries are necessary for Sign-On Credentials as the user will be prompted for the Username and Password when connecting to the network. Enter the Domain\Username (if the Domain is required), otherwise enter the Username. Enter the password.
PEAP/MSCHAP To use PEAP/MSCHAP, make sure the following profile options are used. Enter the SSID of the Access Point assigned to this profile Set EAP Type to PEAP-MSCHAP Set Encryption to WPA TKIP Set Auth Type to Open To use another encryption type, select WPA CCKM, WPA2 AES or WPA2 CCKM for encryption and complete other entries as detailed in this section.
Page 267
Enter these items as directed below. Enter the Domain\Username (if the Domain is required), otherwise enter the Username. Enter the password. Leave the CA Certificate File Name blank for now. Click OK then click Commit. Ensure the correct Active profile is selected on the Main Tab.
Page 268
Once successfully authenticated, import the CA certificate into the Windows certificate store. Return to the Credentials screen and check the Validate server checkbox. If using the Windows certificate store: Check the Use MS store checkbox. The default is to use the Full Trusted Store. To select an individual certificate, click on the Browse button.
PEAP/GTC To use PEAP/GTC, make sure the following profile options are used. Enter the SSID of the Access Point assigned to this profile Set EAP Type to PEAP-GTC Set Encryption to WPA TKIP Set Auth Type to Open To use another encryption type, select WPA CCKM, WPA2 AES or WPA2 CCKM for encryption and complete other entries as detailed in this section.
Page 270
Enter the password. Leave the CA Certificate File Name blank for now. Click OK then click Commit. Ensure the correct Active Profile is selected on the Main Tab. Windows Certificate Store vs. Certs Path for more information on certificate storage. Once successfully authenticated, import the CA certificate into the Windows certificate store.
WPA/LEAP To use WPA/LEAP, make sure the following profile options are used. Enter the SSID of the Access Point assigned to this profile Set EAP Type to LEAP Set Encryption to WPA TKIP Set Auth Type as follows: If the Cisco/CCX certified AP is configured for open authentication, set the Auth Type radio parameter to Open.
Page 272
To use Stored Credentials, click on the Credentials button. No entries are necessary for Sign-On Credentials as the user will be prompted for the Username and Password when connecting to the network. Enter the Domain\Username (if the Domain is required), otherwise enter the Username. Enter the password.
RADIUS server must have auto provisioning enabled to send the PAC provisioning credentials to the MX7. For automatic PAC provisioning, once a username/password is authenticated, the PAC information is stored on the MX7. The same username/password must be used to authenticate each time. See the note below for more details.
Page 274
To use Sign-On credentials: Do not enter a User and Password as the user will be prompted for the Username and Password when connecting to the network. To use Stored Credentials: Enter the Domain\Username (if the Domain is required), otherwise enter the Username. Enter the password.
EAP-TLS To use EAP-TLS, make sure the following profile options are used. Enter the SSID of the Access Point assigned to this profile Set EAP Type to EAP-TLS Set Encryption to WPA TKIP Set Auth Type to Open To use another encryption type, select WPA CCKM, WPA2 AES or WPA2 CCKM for encryption and complete other entries as detailed in this section.
Page 276
Enter these items as directed below. Enter the Domain\Username (if the Domain is required), otherwise enter the Username. Select a user certificate from the Windows certificate store. Use the Browse button to locate the User Cert from the certificate store. Highlight the desired certificate and press the Select button. The name of the certificate is displayed in the User Cert box.
Page 277
The MX7 should be authenticating the server certificate and using EAP-TLS for the user authentication. Ensure the correct Active Profile is selected on the Main tab and warmboot. The SCU Main tab shows the device is associated after the radio connects to the network.
WPA PSK To connect using WPA/PSK, make sure the following profile options are used: Enter the SSID of the Access Point assigned to this profile Set EAP Type to None Set Encryption to WPA PSK or WPA2 PSK Set Auth Type to Open Click the WEP keys/PSKs button.
Generate a User Certificate and Private Key file and download it to a PC. 2. Connect the MX7 to the desktop PC using ActiveSync and copy the certificate and private key file to the MX7 \System folder. Install the User Certificate and Private Key file.
Page 280
Click the Download a CA certificate, certificate chain or CRL link. Make sure the correct root CA certificate is selected in the list box. 7-42...
Page 282
To download the CA certificate, click on the Download CA certificate link. Click the Save button and save the certificate. Make sure to keep track of the name and location of the certificate. Install the certificate on the MX7. 7-44...
This section is only if the Windows certificate store is used. If the certificate store is not used, copy the certificate to the \System folder or other path specified in the Summit Certs global parameter. Copy the certificate file to the MX7. Import the certificate by navigating to Start > Control Panel > Certificates. Tap the Import button.
Page 284
Using the explorer buttons, browse to the location where you copied the certificate, select the certificate desired and tap OK. Tap Yes to import the certificate. Once the certificate is installed, return to the proper authentication section, earlier in this manual. 7-46...
Sign into the CA with the username and password of the person who will be logging into the mobile device. This process saves a user certificate and a separate private key file. Windows CE equipped devices such as the MX7 require the private key to be saved as a separate file rather than including the private key in the user certificate.
Page 286
Click the Request a certificate link. Click on the advanced certificate request link. 7-48...
Page 287
Click on the Create and submit a request to this CA link. 7-49...
Page 288
For the Certificate Template, select User. Check the Mark keys as exportable and the Export keys to file checkboxes. Type the full path on the local PC where the private key is to be copied. Also specify the private key filename. 7-50...
Page 289
Be sure to note the name used for the private key file, for example LXEUSER.PVK. The certificate file created later in this process must be given the same name, for example, LXEUSER.CER. DO NOT check to use strong private key protection. Make any other desired changes and click the Submit button.
Page 290
Click the Download certificate link. Click Save to download and store the user certificate to the PC. Make sure to keep track of the name and location of the certificate. The private key file is also downloaded and saved during this process. Note: Be sure use the same name for the certificate file as was used for the private key file.
Installing a User Certificate Copy the certificate and private key files to the MX7. Import the certificate by navigating to Start > Control Panel > Certificates. Select My Certificates from the pull down list. Tap the Import button. Make sure From a File is selected and tap OK.
Page 292
Using the explorer buttons, browse to the location where you copied the certificate, select the certificate desired and tap OK. The certificate is now shown in the list. With the certificate you just imported highlighted, tap View. From the Field pull down menu, select Private Key. 7-54...
Page 293
If the private key is present, the process is complete. If the private key is not present, import the private key. To import the private key, tap OK to return to the Certificates screen. Tap import. Using the explorer buttons, browse to the location where you copied the private key file, change the Type pull down list to Private Keys, select the certificate desired and tap OK.
Verify Installation Tap on View to see the certificate details again. The private key should now say present. If it does not, there is a problem. Possible items to check: Make sure the certificate was generated with a separate private key file, as shown earlier in this section. If the certificate was not generated with a separate private key file, generate a new certificate and follow the import process again.
The following keypad key map is used on an MX7 that is NOT running a Honeywell Terminal Emulator. Terminal emulators use a separate key map. When using a sequence of keys that includes a sticky key, press the sticky key first, release it, then press the rest of the key sequence.
Page 296
To get this Key / Function Press these Keys in this Order Scan Scan CapsLock (Toggle) Blue Back Space Orange Back Tab Orange Up Arrow Up Arrow Down Arrow Down Arrow Right Arrow Right Arrow Left Arrow Left Arrow Insert Blue I (letter i) Insert...
Page 297
To get this Key / Function Press these Keys in this Order Shft Shft Shft Orange Shft Orange Shft Orange Shft Orange Shft Shft...
Page 298
To get this Key / Function Press these Keys in this Order Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft...
Page 299
To get this Key / Function Press these Keys in this Order . (period) Orange . (period Orange < Blue Blue Blue > Blue Blue Blue Blue Blue Blue Blue * (asterisk) Orange I (letter i) * (asterisk) Shft : (colon) Orange ;...
The following keypad key map is used on an MX7 that is running a 5250 Terminal Emulator. When using a sequence of keys that includes a sticky key, press the sticky key first, release it, then press the rest of the key sequence.
Page 301
To get this 5250 Key / Function Press these Keys in this Order Power / Suspend Power Field Exit (default VK_PAUSE) Blue (MAP) Orange (MAP) Shift (MAP) Diamond #1 MAP = Mappable Volume Adjust Mode Orange Scan Up Arrow / Down Arrow Volume Adjust Mode Blue Up Arrow / Down Arrow...
Page 302
To get this 5250 Key / Function Press these Keys in this Order Orange Orange Orange Orange Orange Blue Blue Blue Blue Blue Shft Shft Shft Shft Shft Shft Orange Shft Orange Shft Orange Shft Orange...
Page 303
To get this 5250 Key / Function Press these Keys in this Order Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft...
Page 304
To get this 5250 Key / Function Press these Keys in this Order Shft Shft Shft Shft . (period) Orange . (period Orange < Blue Blue Blue > Blue Blue Blue Blue Blue Blue Blue * (asterisk) Orange I (letter i) * (asterisk) Shft : (colon)
Page 305
To get this 5250 Key / Function Press these Keys in this Order ' (apostrophe) Orange ~ (tilde) Orange Orange Orange " Orange Orange Shft Orange Shft Orange Shft Orange Shft Orange Shft Orange Shft & Orange & Shft Orange Shft Orange Shft...
The following keypad key map is used on an MX7 that is NOT running a Honeywell Terminal Emulator. Terminal emulators use a separate key map. When using a sequence of keys that require an alpha key, first press the Alph key. Use the Shft sticky key or the Caps key sequence (Blue+Tab) for upper case alphabetic characters.
Page 307
To get this Key / Function Press these Keys in this Order Enter Enter Scan Mode Scan CapsLock (Toggle) Blue Back Space Orange Back Tab Orange Up Arrow Up Arrow Down Arrow Down Arrow Right Arrow Blue Up Arrow Left Arrow Blue Down Arrow Insert...
Page 308
To get this Key / Function Press these Keys in this Order Shft Shft Shft Orange Shft Orange Shft Orange Shft Orange Alpha Alpha Alpha Alpha Alpha Alpha Alpha Alpha Alpha Alpha Alpha Alpha Alpha Alpha Alpha Alpha Alpha Alpha Alpha 7777 Alpha...
Page 309
To get this Key / Function Press these Keys in this Order Shft Alpha Shft Alpha Shft Alpha Shft Alpha Shft Alpha Shft Alpha Shft Alpha Shft Alpha Shft Alpha Shft Alpha Shft Alpha Shft Alpha Shft Alpha Shft Alpha Shft Alpha Shft...
Page 310
To get this Key / Function Press these Keys in this Order . (period) Orange < Blue Blue Orange Blue Orange > Blue Orange Diamond#2 Blue Blue Blue Blue Blue * (asterisk) Orange Diamond#1 * (asterisk) Shft : (colon) Orange ;...
Backspace key. The following key map is used on an MX7 that is NOT running a Honeywell Terminal Emulator. Terminal emulators use a separate keymap. When using a sequence of keys that includes a sticky key, press the sticky key first, release it, then press the rest of the key sequence.
Page 312
To get this Key / Function Press these Keys in this Order Space Enter Enter Scan Scan CapsLock (Toggle) Blue Back Space Bksp Back Tab Orange Up Arrow Up Arrow Down Arrow Down Arrow Right Arrow Right Arrow Left Arrow Left Arrow Insert Blue...
Page 313
To get this Key / Function Press these Keys in this Order Shft Shft Shft Shft Shft Orange Shft Orange Shft Orange Shft Orange 8-19...
Page 314
To get this Key / Function Press these Keys in this Order Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft 8-20...
Page 315
To get this Key / Function Press these Keys in this Order . (period) Orange Bksp . (period Orange < Blue Blue Blue > Blue Blue Blue Blue Blue Blue Blue Bksp * (asterisk) Orange I (letter i) * (asterisk) Shft : (colon) Orange...
Page 316
To get this Key / Function Press these Keys in this Order Shft Orange Shft Orange Shft & Orange & Shft Orange Shft Orange Shft 0 (zero) 8-22...
Dimensions and Weight Dimension Length 8.8” | 22.3 cm Width at Display 3.4” | 8.6 cm Width at handgrip 2.8” | 7.1 cm Depth at Scanner 2” | 5.1 cm Depth at Battery 1.7” | 4.3 cm Weight Unit with network card, battery, 1.6 lbs (26.1 oz) | 740g SE1524ER scanner and handle Unit with network card, battery,...
1, 2, 5.5, 6, 9, 11, 12, 18, 24, 36, 48, 54 Mbps RF Power Level 50 mW max. Channels 1-11 FCC, 1-13 ETSI Operating Temperature Same as MX7 Operating Temperature Storage Temperature Same as MX7 Storage Temperature Connectivity TCP/IP, Ethernet, ODI Diversity Summit 802.11a/b/g CF 2.4/5.0GHz...
Chapter 10: Autovision Keypad Introduction The MX7 Autovision keypad is a specialized optional 55-key keypad. The keypad overlay and certain key functions differ from the standard MX7 55-key keypad. Remember : “Sticky” keys are also known as “second” function keys. Ctrl, Alt, Shft, Blue and Orange keys are “sticky keys”.
Please see Start > Control Panel > Administration > Security tab. The default Hot Key is: Shift + Ctrl + A. This is not valid for the MX7 Autovision keypad since the Ctrl keypress requires multiple keys (Orange + BkSp).
Autovision Key Map When using a sequence of keys that includes a sticky key, press the sticky key first, release it, then press the rest of the key sequence. When using a sequence of keys that includes the Orange or Blue keys, press the color key first then the rest of the key sequence.
Page 324
To get this Autovision Key / Function Press these Keys in this Order Home Shft Down Arrow Shft Up Arrow Page Up Orange Up Arrow Page Down Orange Down Arrow Orange Orange Orange Orange Blue Orange Blue Blue 10-4...
Page 325
To get this Autovision Key / Function Press these Keys in this Order Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft Shft 10-5...
Page 326
To get this Autovision Key / Function Press these Keys in this Order . (period) Orange . (period Orange < Blue Blue Blue > Blue Blue Blue Blue Blue Blue Bksp Blue * (asterisk) Orange I (letter i) * (asterisk) Shft : (colon) Orange...
Page 327
To get this Autovision Key / Function Press these Keys in this Order " Orange Orange Shft Orange Shft Orange Shft Orange Shft Orange Shft Orange Shft & Orange & Shft Orange Shft Orange Shft 0 (zero) 10-7...
Portal (see below) provides an easy way to report your problem or ask your question. Product Service and Repair: www.honeywellaidc.com Honeywell International Inc. provides service for all of its products through service centers throughout the world. To obtain warranty or non-warranty service, please visit www.honeywellaidc.com and select Support >...
Page 330
Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.com E-EQ-MX7RG Rev W 4/12...
Need help?
Do you have a question about the MX7 and is the answer not in the manual?
Questions and answers