Page 3
When transporting/installing the equipment, employ two persons and be sure to use the positions as indicated below. The equipment is quite heavy and weighs approximately 83kg (182.98 lb.): e-STUDIO350/450 / 86kg (189.59 lb.): e-STUDIO352/353/452/453 therefore pay fullattention when handling it.
Page 4
If these parts are shorted circuit and/or made their functions out, they may burn down, for instance, and may result in fatal accidents. Do not allow a short circuit to occur. Do not use the parts not recommended by Toshiba TEC Corporation. 4) Cautionary Labels During servicing, be sure to check the rating plate and the cautionary labels such as “Unplug the...
Page 5
Caution: Dispose of used batteries and IC-RAMs including lithium batteries according to this manual. Attention: Se débarrasser de batteries et IC-RAMs usés y compris les batteries en lithium selon ce manuel. Vorsicht: Entsorgung der gebrauchten Batterien und IC-RAMs (inklusive der Lithium-Batterie) nach diesem Handbuch. 06/09...
Page 9
4.2 General Descriptions for PM Procedure (Maintenance Performed Every 120,000 Output Pages (e-STUDIO350/352/353) and 150,000 Output Pages (e-STUDIO450/452/453)) ..4-7 4.3 Operational Items in Overhauling ..................4-8 4.4 Cleaning the Units which Have Processed 60,000 Output Pages (e-STUDIO350/352/353) and 75,000 Output Pages (e-STUDIO450/452/453)............4-9 4.5 Preventive Maintenance Checklist..................4-10 4.6 PM KIT..........................
Page 10
6.3 Firmware Updating with FSMS (Field Service Manager) (e-STUDIO350/450) ....6-66 6.4 Firmware Updating with USB Storage Device (e-STUDIO350/450)........6-79 6.5 Firmware Updating with USB Storage Device (e-STUDIO352/353/452/453)....6-91 6.6 Appendix.......................... 6-115 6.6.1 e-STUDIO350/450....................6-115 6.6.2 e-STUDIO352/353/452/453.................. 6-116 7. POWER SUPPLY UNIT ....................7-1 7.1 Output Channel ........................
SPECIFICATIONS / ACCESSORIES / OPTIONS / SUPPLIES Specifications Values in [ ] are for e-STUDIO450/452/453 in case that the specification is different between e-STUDIO350/ 352/353 and e-STUDIO450/452/453. • Copy process Indirect electrophotographic process (dry) • Type Desktop type (console type: when paper feed pedestal (PFP) and large capacity feeder (LCF) are installed) •...
Toshiba Tec First copy time ...... e-STUDIO350/352/353: Approx. 3.9sec. or less e-STUDIO450/452/453: Approx. 3.9sec. or less (A4/LT, upper drawer, 100%, original placed manually) Warming-up time ....Approx. 20 seconds (temperature: 20°C) Multiple copying....Up to 999 copies; Key in set numbers Reproduction ratio ....
(Press to display the screen on the control panel at power-ON.) • Test mode (03): Refer to P. 2-27 "2.2.1 Input check (Test mode 03) (e-STUDIO350/450)"/ P. 2-34 "2.2.2 Input check (Test mode 03) (e-STUDIO352/353/452/453)" and P. 2-42 "2.2.3 Output check (test mode 03)".
Refer to P. 2-46 "2.2.5 Adjustment mode (05) (e-STUDIO350/450)" for the details. Errors such as paper jamming may occur if the EEPROM is not initialized and the sensors are not adjusted after the above mentioned parts were replaced.
Operational Items in Overhauling Overhaul each equipment with the following timing. e-STUDIO350/352/353: When the number of output pages has reached 360,000 or 2.5 years have passed from the start of use (Whichever is earlier) e-STUDIO450/452/453: When the number of output pages has reached 450,000 or 2.5 years have passed from the start of use (Whichever is earlier) Replace all the supplies.
(KS-660) [Preventive Maintenance Checklist] Notes: 1. Perform cleaning and lubricating in every 120,000 output pages for the e-STUDIO350/352/ 353, and every 150,000 output pages for the e-STUDIO450/452/453. Lubricate the replace- ment parts following to the replacement cycle. 2. Values under “Replacement” indicate the replacement cycle for the e-STUDIO350/e- STUDIO450, e-STUDIO352/e-STUDIO452, or e-STUDIO353/e-STUDIO453.
Page 529
Compare the serial number of the equipment with a number displayed in 08-995. If they are different, enter the correct serial number at 08-995. [F200] Data overwrite kit (GP-1050) is taken off (e-STUDIO350/450) Clear the service call “F200”. (Key in “0” at 08-633.) * When the Data overwrite kit (GP-1050) is removed from the equipment, the service call “F200”...
Install NVRAM to the new SYS board (from the old SYS board). Install NIC board to the new SYS board (from the old SYS board). (e-STUDIO350/450) Update the version of system ROMs (System Firmware, OS data, UI data) (The ROMs had been used for the old SYS board).
P. 6-3 "6.1 Firmware Updating with Download Jig (e-STUDIO350/450)" • Updating with PC connected P. 6-66 "6.3 Firmware Updating with FSMS (Field Service Manager) (e-STUDIO350/450)" • Updating with the USB Storage Device P. 6-79 "6.4 Firmware Updating with USB Storage Device (e-STUDIO350/450)"...
Page 656
Connect the USB storage device to the PC and write the data file. • Confirm the data file name before writing P. 6-79 "6.4 Firmware Updating with USB Storage Device (e-STUDIO350/450)"). • The file system of USB storage device should be formatted in FAT format.
Page 694
1) Not linked with the door switch CN412 For the SYS board CN413 For the LGC board, FIL board / FUS board, FAX board (e-STUDIO350/450 only), PFP/LCF (via LGC board), Bridge unit / Job separator / Offset tray (via LGC board) CN415...
Page 761
10.4 DC Wire Harness (e-STUDIO352/353/452/453) 07/11...
Page 762
Exposure lamp ON signal RET1 Button scanning return signal (1) L: e-STUDIO350 DQS4 Data strobe signal [4] AD[28] PCI address/data bus [28] CPSW2-0 e-STUDIO350/450 judgment signal ATSVR-1A Black auto-toner sensor reference voltage Analog +24VD4 +24V RET2 Button scanning return signal (2) H: e-STUDIO450...
Need help?
Do you have a question about the e-STUDIO350 and is the answer not in the manual?
Questions and answers