Sign In
Upload
Manuals
Brands
ABB Manuals
DC Drives
ACS880-37LC
ABB ACS880-37LC Manuals
Manuals and User Guides for ABB ACS880-37LC. We have
14
ABB ACS880-37LC manuals available for free PDF download: Firmware Manual, Hardware Manual, User Manual, Manual
ABB ACS880-37LC Firmware Manual (604 pages)
primary control program
Brand:
ABB
| Category:
Servo Drives
| Size: 5.39 MB
Table of Contents
Table of Contents
5
Safety Instructions
11
Target Audience
11
Introduction to the Manual
11
Applicability
11
What this Chapter Contains
11
Contents of the Manual
12
Related Documents
12
Terms and Abbreviations
13
Cybersecurity Disclaimer
16
Using the Control Panel
17
Control Locations and Operating Modes
19
What this Chapter Contains
19
Local Control Vs. External Control
20
Local Control
20
External Control
21
Operating Modes of the Drive
22
DC Voltage Control Mode
23
Special Control Modes
23
Torque Control Mode
23
Speed Control Mode
23
Frequency Control Mode
23
Program Features
25
What this Chapter Contains
25
Drive Configuration and Programming
26
Programming Via Parameters
26
Adaptive Programming
27
Application Programming
27
Programmable Digital Inputs and Outputs
28
Control Interfaces
28
Programmable Analog Outputs
28
Programmable Analog Inputs
28
Programmable Relay Outputs
29
Programmable I/O Extensions
29
Fieldbus Control
30
Master/Follower Functionality
31
External Controller Interface
39
Control of a Supply Unit (LSU)
41
Motor Control
42
Direct Torque Control (DTC)
42
Reference Ramping
42
Constant Speeds/Frequencies
43
Critical Speeds/Frequencies
43
Speed Controller Autotune
44
Oscillation Damping
47
Resonance Frequency Elimination
48
Rush Control
48
Encoder Support
49
Jogging
55
Scalar Motor Control
58
Autophasing
59
Flux Braking
62
DC Magnetization
63
Hexagonal Motor Flux Pattern
65
Process PID Control
66
Application Macros
66
Application Control
66
Motor Potentiometer
69
Mechanical Brake Control
70
DC Voltage Control
75
Overvoltage Control
75
Undervoltage Control (Power Loss Ride-Through)
75
Voltage Control and Trip Limits
76
Brake Chopper
77
DC Voltage Control Mode
78
Safety and Protections
79
Emergency Stop
79
Motor Thermal Protection
80
Motor Overload Protection
83
Thermal Protection of Motor Cable
84
User Load Curve
84
Automatic Fault Resets
85
Other Programmable Protection Functions
86
Maintenance Timers and Counters
88
Fault and Warning Messages, Data Logging
88
Signal Supervision
88
Diagnostics
88
Energy Saving Calculators
89
Load Analyzer
89
Miscellaneous
91
User Parameter Sets
91
Parameter Checksum Calculation
91
User Lock
92
Reduced Run Function
93
Data Storage Parameters
93
Du/Dt Filter Support
94
Sine Filter Support
95
Router Mode for BCU Control Unit
95
Application Macros
97
What this Chapter Contains
97
General
97
Factory Macro
98
Default Parameter Settings for the Factory Macro
98
Default Control Connections for the Factory Macro
99
Hand/Auto Macro
100
Default Parameter Settings for the Hand/Auto Macro
100
Default Control Connections for the Hand/Auto Macro
101
PID Control Macro
102
Default Parameter Settings for the PID Control Macro
103
Default Control Connections for the PID Control Macro
104
Sensor Connection Examples for the PID Control Macro
105
Torque Control Macro
106
Default Parameter Settings for the Torque Control Macro
106
Default Control Connections for the Torque Control Macro
107
Sequential Control Macro
108
Operation Diagram
108
Selection of Constant Speeds
109
Default Parameter Settings for the Sequential Control Macro
109
Default Control Connections for the Sequential Control Macro
110
Fieldbus Control Macro
111
Parameters
113
What this Chapter Contains
113
Terms and Abbreviations
114
Advertisement
ABB ACS880-37LC Hardware Manual (202 pages)
Industrial Drives
Brand:
ABB
| Category:
DC Drives
| Size: 7.23 MB
Table of Contents
Table of Contents
5
Table of Contents
7
Table of Contents
9
1 Safety Instructions
13
Contents of this Chapter
13
Use of Warnings and Notes
13
General Safety in Installation, Start-Up and Maintenance
14
Work on the Liquid Cooling System
15
Electrical Safety in Installation, Start-Up and Maintenance
17
Electrical Safety Precautions
17
Additional Instructions and Notes
18
Optical Components
18
Printed Circuit Boards
19
Grounding
19
Additional Instructions for Permanent Magnet Motor Drives
20
Safety in Installation, Start-Up, Maintenance
20
Safety in Operation
20
2 Introduction to the Manual
21
Contents of this Chapter
21
Target Audience
21
Categorization by Frame Size and Option Code
21
Use of Component Designations
22
Quick Installation, Commissioning and Operation Flowchart
22
Terms and Abbreviations
23
Related Manuals
23
3 Operation Principle and Hardware Description
25
Contents of this Chapter
25
Supply Unit
25
AC Voltage and Current Waveforms
26
Charging
26
Inverter Unit
26
Overview Circuit Diagram of the Drive
27
Cabinet Line-Up and Layout Examples
28
Frame 3×R8I + 3×R8I
28
Overview of Power and Control Connections
29
Door Switches and Lights
30
Main Disconnecting Device (Q1.1)
30
Auxiliary Voltage Switch (Q21)
30
Grounding (Earthing) Switch (Q9.X), Optional
30
Other Devices on the Door
30
Control Panel
31
Control by PC Tools
31
Descriptions of Options
32
Degree of Protection
32
Definitions
32
Marine Construction (Option +C121)
32
Plinth Height (Options +C164 and +C179)
32
Resistor Braking (Options +D150 and +D151)
32
Cabinet Heater with External Supply (Option +G300)
32
Cabinet Lighting (Option +G301)
33
Terminals for External Control Voltage (Option +G307)
33
Output for Motor Space Heater (Option +G313)
33
Halogen-Free Wiring and Materials (Option +G330)
33
V-Meter with Selector Switch (Option +G334)
33
A-Meter in One Phase (Option +G335)
33
Additional Wire Markings
33
Standard Wire Markings
33
Additional Wire Markings
34
Common Motor Terminal Cubicle (Option +H359)
35
Starter for Auxiliary Motor Fan (Options +M6Xx)
35
What the Option Contains
35
Description
35
Type Designation Label
36
Type Designation Key
36
4 Mechanical Installation
41
Contents of this Chapter
41
Examining the Installation Site
41
Necessary Tools
41
Checking the Delivery
42
Moving and Unpacking the Drive
43
Moving the Drive in Its Packaging
43
Lifting the Crate with a Forklift
43
Lifting the Crate with a Crane
44
Moving the Crate with a Forklift
45
Removing the Transport Package
45
Moving the Unpacked Drive Cabinet
46
Lifting the Cabinet with a Crane
46
Moving the Cabinet on Rollers
47
Moving the Cabinet on Its Back
47
Final Placement of the Cabinet
48
Fastening the Cabinet to the Floor and Wall or Roof
49
General Rules
49
Fastening the Cabinet (Non-Marine Units)
50
Alternative 1 - Clamping
50
Alternative 2 - Using the Holes Inside the Cabinet
51
Fastening the Cabinet (Marine Units)
52
Joining Cabinet Sections Together
53
Miscellaneous
56
Cable Duct in the Floor below the Cabinet
56
Arc Welding
56
5 Guidelines for Planning the Electrical Installation
57
Contents of this Chapter
57
Limitation of Liability
57
Selecting the Supply Disconnecting Device
57
Selecting the Main Contactor or Breaker
57
Examining the Compatibility of the Motor and Drive
58
Protecting the Motor Insulation and Bearings
58
Requirements Table
58
Availability of Du/Dt Filter and Common Mode Filter by Drive or Inverter Type
61
Additional Requirements for Explosion-Safe (EX) Motors
61
And am
61
Additional Requirements for Braking Applications
61
Additional Requirements for the Regenerative and Low Harmonics Drives
61
Additional Requirements for ABB High-Output and IP23 Motors
61
Additional Requirements for Non-ABB High-Output and IP23 Motors
61
Additional Note for Sine Filters
62
Selecting the Power Cables
62
General Guidelines
62
Typical Power Cable Sizes
63
Power Cable Types
64
Recommended Power Cable Types
64
Alternate Power Cable Types
64
Not Allowed Power Cable Types
65
Power Cable Shield
65
Planning the Resistor Braking System
66
Selecting the Control Cables
66
Shielding
66
Signals in Separate Cables
66
Signals that Can be Run in the same Cable
66
Relay Cable Type
66
Control Panel to Drive Connection
66
Routing the Cables
67
General Guidelines, IEC
67
Continuous Motor Cable Shield or Enclosure for Equipment on the Motor Cable
67
Separate Control Cable Ducts
68
Implementing Thermal Overload and Short-Circuit Protection
68
Protecting the Input Cabling and the Drive Upon a Short-Circuit
68
Protecting the Motor and Motor Cable in Short-Circuits
68
Protecting the Drive and the Power Cables against Thermal Overload
68
Protecting the Motor against Thermal Overload
68
Protecting the Drive against Ground Faults
69
Residual Current Device Compatibility
69
Implementing the Emergency Stop Function
69
Implementing the Safe Torque off Function
69
Implementing the Power Loss Ride-Through Function
69
Using Power Factor Compensation Capacitors with the Drive
70
Implementing a Safety Switch between the Drive and the Motor
70
Using a Contactor between the Drive and the Motor
70
Implementing a Bypass Connection
70
Implementing the ATEX-Certified Safe Motor Disconnection Function (Option +Q971)
71
Protecting the Contacts of Relay Outputs
71
Connecting Motor Temperature Sensor to the Drive Via an Option Module
72
Protecting the Drive against Ground Faults
72
Residual Current Device Compatibility
72
Implementing the Emergency Stop Function
72
Implementing the Safe Torque off Function
73
Implementing the Prevention of Unexpected Start-Up Function
73
Implementing the Functions Provided by the FSO-XX Safety Functions Module
73
Implementing the Power-Loss Ride-Through Function
73
Implementing a Bypass Connection
74
Supplying Power for the Auxiliary Circuits
74
Using Power Factor Compensation Capacitors with the Drive
74
Using a Safety Switch between the Drive and the Motor
75
Protecting the Contacts of Relay Outputs
75
Implementing a Motor Temperature Sensor Connection
75
Connecting Motor Temperature Sensor to the Drive Via an Option Module
76
Connection of Motor Temperature Sensor to the Drive Via a Relay
76
6 Electrical Installation
79
Contents of this Chapter
79
Warnings
79
Checking the Insulation of the Assembly
79
Checking the Insulation of the Drive System
79
Checking the Insulation of the Motor and Motor Cable
79
Connecting the Control Cables
81
Control Cable Connection Procedure
81
Grounding the Outer Shields of the Control Cables at the Cabinet Entry
81
Routing the Control Cables Inside the Cabinet
83
Connecting Control Cabling
83
Connecting the Motor Cables (Units Without Common Motor Terminal Cubicle)
85
Motor Connection Diagram (Without Option +H366)
85
Procedure
86
Connecting the Motor Cables (Units with Common Motor Terminal Cubicle)
88
Output Busbars
88
Connection Diagram
88
Procedure
88
Connecting an External Brake Resistor Assembly
89
Connecting the Input Power Cables
90
Connection Diagram
90
Layout of the Input Cable Connection Terminals and Cable Entries
90
Connection Procedure
90
Connecting a PC
93
Panel Bus (Control of Several Units from One Control Panel)
93
Installing Option Modules
95
Mechanical Installation of I/O Extension, Fieldbus Adapter and Pulse Encoder Interface Modules
95
Installation of an FSO-XX Safety Functions Module Onto BCU
96
Wiring of Optional Modules
98
7 Control Units of the Drive
99
Contents of this Chapter
99
General
99
BCU-X2 Control Unit Layout and Connections
100
Default I/O Diagram of the Supply Control Unit
102
Default I/O Diagram of the Inverter Control Unit (A41)
103
External Power Supply for the Control Unit (XPOW)
105
DI6 as a PTC Sensor Input
105
AI1 or AI2 as a Pt100, Pt1000, PTC or KTY84 Sensor Input
105
DIIL Input
106
The XD2D Connector
106
Safe Torque off (XSTO, XSTO OUT)
107
FSO-XX Safety Functions Module Connection (X12)
107
SDHC Memory Card Slot
107
Connector Data
108
BCU-X2 Ground Isolation Diagram
110
8 Installation Checklist of the Drive
111
Contents of this Chapter
111
Checklist
111
9 Start-Up
113
Contents of this Chapter
113
Start-Up Procedure
113
Switching off the Drive
115
10 Fault Tracing
117
Contents of this Chapter
117
Control Unit Leds
117
Control Panel and Panel Platform/Holder Leds
117
Warning and Fault Messages
118
ABB ACS880-37LC User Manual (84 pages)
ATEX-certified motor thermal protection functions for cabinet-built drives
Brand:
ABB
| Category:
DC Drives
| Size: 2.14 MB
Table of Contents
Table of Contents
5
1 Safety Instructions
9
Contents of this Chapter
9
Use of Warnings and Notes
9
ATEX-Certified Motor Thermal Protection Functions
9
Electrical Safety Precautions
11
2 Introduction to the Manual
13
Contents of this Chapter
13
Applicability
13
Target Audience
13
Exclusion of Liability
14
Terms and Abbreviations
14
Related Manuals
15
3 ATEX-Certified Motor Thermal Protection Function with PTC Thermistor Relays
17
(+L513+Q971)
17
Contents of this Chapter
17
Option Description
17
Operation Principle
19
Without an FSO Module
19
With an FSO Module
20
Implementation of the Manual Reset
21
Indications of the Motor Thermal Protection Function
21
Commissioning the Drive for a Motor in a Hazardous Area
21
PTC Thermistor Relays
22
ABB CM-MSS.41 Thermistor Motor Protection Relay
22
Layout
22
Operation Diagram
23
DOLD MK 9163N.12/110-ATEX Thermistor Relay
23
Layout
23
Operation Diagram
24
Wiring
24
Insulation of the Sensor Circuit
24
General Wiring Instructions
25
Wiring Example
25
Start-Up and Acceptance Test
26
Maintenance
27
Fault Tracing
27
Safety Data and Block Diagrams
27
Without an FSO Module
27
With an FSO Module
28
4 ATEX-Certified Motor Thermal Protection Function with Pt100 Relays
29
(+L514+Q971)
29
Contents of this Chapter
29
Option Description
29
Pt100 Relays
30
Operation Principle
31
Without an FSO Module
31
With an FSO Module
32
Implementation of the Manual Reset
33
Indications of the Motor Thermal Protection Function
33
Commissioning the Drive for a Motor in a Hazardous Area
33
Pt100 Relays
34
GM International D1073S Relay (Programmable)
34
Layout
34
PR Electronics 9116B1 Universal Converter Relay (Programmable)
35
Layout
35
Pt100 Relay Programming
35
Wiring
35
Insulation of the Sensor Circuit
35
General Wiring Instructions
36
Wiring Example
37
Start-Up and Acceptance Test
37
Maintenance
38
Fault Tracing
38
Safety Data and Block Diagrams
39
Without an FSO Module
39
With an FSO Module
40
Advertisement
ABB ACS880-37LC User Manual (74 pages)
Brand:
ABB
| Category:
DC Drives
| Size: 1.33 MB
Table of Contents
Table of Contents
5
1 Safety Instructions
9
Contents of this Chapter
9
Use of Warnings and Notes
9
Instructions for Functional Safety Circuits
9
Electrical Safety Precautions
10
2 Introduction to the Manual
13
Contents of this Chapter
13
Applicability
13
Target Audience
13
Exclusion of Liability
14
Quick Reference Guide for Taking a Safety Function into Use
14
Related Manuals
14
Terms and Abbreviations
16
3 Option Description
17
Contents of this Chapter
17
Overview
17
Summary of Wirings and Settings
18
Operation Principle
20
Time Schemes with a Speed Estimate (no Safety Encoder)
21
Emergency Stop, Stop Category 0
21
Emergency Stop, Stop Category 1 with Time Monitoring
22
Emergency Stop, Stop Category 1 with Ramp Monitoring
24
Time Schemes with a Safety Encoder
27
Emergency Stop, Stop Category 0
27
Emergency Stop, Stop Category 1 with Time Monitoring
28
Emergency Stop, Stop Category 1 with Ramp Monitoring
30
Operation Principle Diagrams
32
ACS880-07 Drives, Frames R6 to R11 and ACS880-17/-37 Drives, Frame R8
32
ACS880-07/07LC Drives, Frames N×Dxt + N×R8I
33
ACS880-17/17LC/37/37LC Drives, Frames N×R8I + N×R8I
35
ACS880-17/37 Drives, Frame R11
37
Fault Reaction Function
38
FSO Module
38
Resetting the FSO Module
38
FSE-31 Module
39
Safety Encoder
39
STO Function in the Drive
39
4 Electrical Installation
41
Contents of this Chapter
41
Wiring
41
Customer-Installed Main Breaker in ACS880-07LC/17LC/37LC Drives
42
5 Parameter Settings
43
Contents of this Chapter
43
Competence
43
FSO Module Parameter Settings
43
General Parameters
44
Parameters for the STO Function
46
Parameters for the SSE Function
48
I/O Parameters
49
Parameters for Emergency Stop, Stop Category 0
50
Parameters for Emergency Stop, Stop Category 1
51
Changing the Stop Category from 0 to 1
53
FSE-31 Module and Safety Pulse Encoder Related Parameters
54
Drive Parameter Settings
55
Additional Parameter Settings for ACS880-07/07LC Drives, Frames N×Dxt + N×R8I and ACS880-17/17LC/37/37LC Drives, Frames N×R8I + N×R8I
55
Additional Parameter Settings for ACS880-17/37, Frames R8 and R11
55
Safety Pulse Encoder Parameters
56
SS1 Ramp Parameters
56
ABB ACS880-37LC Manual (66 pages)
Safely-limited speed with the encoder interface (option +Q965)
Brand:
ABB
| Category:
DC Drives
| Size: 1.29 MB
Table of Contents
Table of Contents
5
1 Safety Instructions
7
Contents of this Chapter
7
Use of Warnings and Notes
7
Instructions for Functional Safety Circuits
8
Electrical Safety Precautions
9
2 Introduction to the Manual
11
Contents of this Chapter
11
Applicability
11
Target Audience
11
Exclusion of Liability
12
Quick Reference Guide for Taking a Safety Function into Use
12
Related Manuals
12
Terms and Abbreviations
14
3 Option Description
15
Contents of this Chapter
15
Overview
15
Summary of Wirings and Settings
16
Operation Principle
17
SLS Function
17
SLS with Speed below the Monitored Speed
18
SLS with Speed above the Monitored Speed - Time Monitoring
20
SLS with Speed above the Monitored Speed - Ramp Monitoring
22
SLS Reaction When Modulation Is Lost During Deceleration Ramp
23
SMS Function
28
SSM Function
29
Drive Modulation Loss When Encoder Feedback Is Used
30
Operation Principle Diagram
31
Fault Reaction Function
32
FSO Module
32
Resetting the FSO Module
32
FSE-31 Module and Safety Encoder
32
Drive STO Function
33
4 Electrical Installation
35
Contents of this Chapter
35
Wiring
35
SLS Function
36
SMS Function
36
SSM Function
36
5 Parameter Settings
37
Contents of this Chapter
37
Competence
37
FSO Module Parameter Settings
37
General Parameters
38
Parameters for the STO Function
39
Parameters for the SSE Function
40
Parameters for the SLS Function
43
Parameters for the SMS Function
46
Parameters for the SSM Function
46
FSE-31 Module and Safety Pulse Encoder Related Parameters
47
Drive Parameter Settings
49
Ramp Parameters
49
ABB ACS880-37LC User Manual (62 pages)
Safely-limited speed with the encoder interface (option +Q965)
Brand:
ABB
| Category:
DC Drives
| Size: 1.24 MB
Table of Contents
Table of Contents
5
1 Safety Instructions
7
Contents of this Chapter
7
Use of Warnings and Notes
7
Instructions for Functional Safety Circuits
7
Electrical Safety Precautions
8
2 Introduction to the Manual
11
Contents of this Chapter
11
Applicability
11
Target Audience
11
Exclusion of Liability
12
Quick Reference Guide for Taking a Safety Function into Use
12
Related Manuals
12
Terms and Abbreviations
14
3 Option Description
15
Contents of this Chapter
15
Overview
15
Summary of Wirings and Setting
16
Operation Principle
17
SLS Function
17
SLS with Speed below the Monitored Speed
18
SLS with Speed above the Monitored Speed - Time Monitoring
19
SLS with Speed above the Monitored Speed - Ramp Monitoring
20
SLS Reaction When Modulation Is Lost During Deceleration Ramp, with Ramp Monitoring
21
SMS Function
27
SSM Function
28
Drive Modulation Loss When Encoder Feedback Is Used
29
Operation Principle Diagram
29
Fault Reaction Function
31
FSO Module
31
FSE-31 Module
31
Safety Encoder
32
STO Function in the Drive
32
Parameter Settings
32
FSO Module Parameter Settings
32
General Parameters
33
Parameters for the STO Function
34
Parameters for the SSE Function
36
Parameters for the SLS Function
38
Parameters for the SMS Function
42
Parameters for the SSM Function
43
FSE-31 Module and Safety Pulse Encoder Related Parameters
44
Drive Parameter Settings
46
Ramp Parameters
46
Safety Pulse Encoder Parameters
46
4 Electrical Installation
47
Contents of this Chapter
47
Wiring
47
SLS Function
48
SMS Function
48
SSM Function
48
ABB ACS880-37LC User Manual (58 pages)
Emergency stop, configurable stop category 0 or 1 (option +Q979)
Brand:
ABB
| Category:
DC Drives
| Size: 1.11 MB
Table of Contents
Table of Contents
5
1 Safety Instructions
7
Contents of this Chapter
7
Use of Warnings and Notes
7
Instructions for Functional Safety Circuits
8
Electrical Safety Precautions
9
2 Introduction to the Manual
11
Contents of this Chapter
11
Applicability
11
Target Audience
11
Exclusion of Liability
12
Quick Reference Guide for Taking a Safety Function into Use
12
Related Manuals
12
Terms and Abbreviations
14
3 Option Description
15
Contents of this Chapter
15
Overview
15
Summary of Wirings and Settings
16
Operation Principle
17
Time Schemes with a Speed Estimate (no Safety Encoder)
18
Emergency Stop, Stop Category 0
18
Emergency Stop, Stop Category 1 with Time Monitoring
19
Emergency Stop, Stop Category 1 with Ramp Monitoring
21
Time Schemes with a Safety Encoder
23
Emergency Stop, Stop Category 0
23
Emergency Stop, Stop Category 1 with Time Monitoring
24
Emergency Stop, Stop Category 1 with Ramp Monitoring
26
Operation Principle Diagrams
28
Fault Reaction Function
29
FSO Module
29
Resetting the FSO Module
30
FSE-31 Module and Safety Encoder
30
Drive STO Function
30
4 Electrical Installation
31
Contents of this Chapter
31
Wiring
31
5 Parameter Settings
33
Contents of this Chapter
33
Competence
33
FSO Module Parameter Settings
33
General Parameters
34
Parameters for the STO Function
36
Parameters for the SSE Function
38
I/O Parameters
38
Parameters for Emergency Stop, Stop Category 0
39
Parameters for Emergency Stop, Stop Category 1
39
Changing the Stop Category from 0 to 1
41
FSE-31 Module and Safety Pulse Encoder Related Parameters
42
Drive Parameter Settings
44
ABB ACS880-37LC User Manual (58 pages)
Emergency stop, stop category 1 (option +Q952) for
Brand:
ABB
| Category:
DC Drives
| Size: 1.08 MB
Table of Contents
Table of Contents
5
1 Safety Instructions
9
Contents of this Chapter
9
Use of Warnings and Notes
9
Instructions for Functional Safety Circuits
9
Electrical Safety Precautions
10
2 Introduction to the Manual
13
Contents of this Chapter
13
Applicability
13
Target Audience
13
Exclusion of Liability
13
Quick Reference Guide for Taking a Safety Function into Use
14
Related Manuals
14
Terms and Abbreviations
15
3 Option Description
17
Contents of this Chapter
17
Overview
17
Operation Principle
18
ACS880-07 Drives, Frames R6 to R11 and ACS880-17/-37 Drives, Frame R8
18
ACS880-17/37 Drives, Frame R11
20
ACS880-07/07LC Drives, Frames N×Dxt + N×R8I
22
ACS880-17/37 and -17LC/37LC Drives, Frames N×R8I + N×R8I
24
Fault Reaction Function
26
Hardware Settings
26
4 Electrical Installation
27
Contents of this Chapter
27
Wiring
27
Customer-Installed Main Breaker in ACS880-07LC/17LC/37LC Drives
28
5 Parameter Settings
29
Contents of this Chapter
29
Drive Parameter Settings
29
Additional Parameter Settings for ACS880-07/07LC Drives, Frames N×Dxt + N×R8I and ACS880-17/17LC/37/37LC Drives, Frames N×R8I + N×R8I
30
Additional Parameter Settings for ACS880-17/37, Frames R8 and R11
31
6 Use of the Safety Function
33
Contents of this Chapter
33
Activating the Safety Function
33
Resetting the Safety Function
33
7 Start-Up and Acceptance Test
35
Contents of this Chapter
35
Validation of the Safety Functions
35
Competence
35
Validation Procedure
35
Acceptance Test Reports
36
Start-Up and Acceptance Test
36
8 Fault Tracing
39
Contents of this Chapter
39
ACS880-07 Drives, Frames R6 to R11 and ACS880-17/37 Drives, Frames R8 and R11
40
Reporting Problems and Failures Related to Safety Functions
40
9 Maintenance
41
Contents of this Chapter
41
Safety Circuit Maintenance
41
Proof Test Interval
42
Competence
42
Residual Risk
42
Intentional Misuse
42
Decommissioning
42
ABB ACS880-37LC User Manual (48 pages)
OPTIONS FOR DRIVES, Emergency stop, stop category 1 option
Brand:
ABB
| Category:
DC Drives
| Size: 1.08 MB
Table of Contents
Table of Contents
5
1 Safety Instructions
7
Contents of this Chapter
7
Use of Warnings and Notes
7
Instructions for Functional Safety Circuits
7
Electrical Safety Precautions
8
2 Introduction to the Manual
9
Contents of this Chapter
9
Applicability
9
Target Audience
9
Exclusion of Liability
9
Quick Reference Guide for Taking a Safety Function into Use
10
Related Manuals
10
Terms and Abbreviations
12
3 Option Description
13
Contents of this Chapter
13
Overview
13
Operation Principle
13
ACS880-07 Drives, Frames R6 to R11 and ACS880-17/-37 Drives, Frame R8
14
ACS880-17/37 Drives, Frame R11
16
ACS880-07 Drives, Frames Nxdxt + Nxr8I
18
ACS880-17/37 and -17LC/37LC Drives, Frames Nxr8I + Nxr8I
20
Fault Reaction Function
21
Parameter Settings
22
Drive Parameter Settings
22
Additional Parameter Settings for ACS880-07 Drives, Frames Nxdxt + Nxr8I and ACS880-17/17LC/37/37LC Drives, Frames Nxr8I + Nxr8I
23
Additional Parameter Settings for ACS880-17/37, Frames R8 and R11
23
Hardware Settings
23
4 Electrical Installation
25
Contents of this Chapter
25
Wiring
25
Customer-Installed Main Breaker in ACS880-17LC/37LC Drives
26
5 Use of the Safety Function
27
Contents of this Chapter
27
Activating the Safety Function
27
Resetting the Safety Function
27
6 Start-Up and Acceptance Test
29
Contents of this Chapter
29
Validation of the Safety Functions
29
Competence
29
Validation Procedure
29
Acceptance Test Reports
30
30 Start-Up and Acceptance Test
30
7 Fault Tracing
33
Contents of this Chapter
33
ACS880-07 Drives, Frames R6 to R11 and ACS880-17/37 Drives, Frame R11
34
Reporting Problems and Failures Related to Safety Functions
34
8 Maintenance
35
Contents of this Chapter
35
Safety Circuit Maintenance
35
Proof Test Interval
35
Competence
36
Residual Risk
36
Intentional Misuse
36
Decommissioning
36
ABB ACS880-37LC User Manual (42 pages)
Brand:
ABB
| Category:
DC Drives
| Size: 1 MB
Table of Contents
Table of Contents
5
1 Safety Instructions
7
Contents of this Chapter
7
Use of Warnings and Notes
7
Instructions for Functional Safety Circuits
8
Electrical Safety Precautions
9
2 Introduction to the Manual
11
Contents of this Chapter
11
Applicability
11
Target Audience
11
Exclusion of Liability
12
Quick Reference Guide for Taking a Safety Function into Use
12
Related Manuals
12
Terms and Abbreviations
14
3 Option Description
15
Contents of this Chapter
15
Overview
15
Summary of Wirings and Settings
16
Operation Principle
17
Time Scheme
17
Operation Principle Diagram
18
Fault Reaction Function
19
FSO Module
19
Resetting the FSO Module
19
Drive STO Function
19
4 Electrical Installation
21
Contents of this Chapter
21
Wiring
21
5 Parameter Settings
23
Contents of this Chapter
23
Competence
23
FSO Module Parameter Settings
23
General Parameters
24
Parameters for the STO Function
25
Parameters for the SSE Function
25
Parameters for the POUS Function
25
Drive Parameter Settings
27
6 Use of the Safety Function
29
Contents of this Chapter
29
Activating the Safety Function
29
Resetting the Safety Function
29
7 Start-Up and Validation Test
31
Contents of this Chapter
31
Validation of the Safety Functions
31
Competence
31
Validation Procedure
31
Validation Test Reports
32
Start-Up and Validation Test
32
8 Maintenance
35
Contents of this Chapter
35
Safety Circuit Maintenance
35
Proof Test Interval
35
Competence
36
Residual Risk
36
Intentional Misuse
36
Decommissioning
36
ABB ACS880-37LC User Manual (36 pages)
Emergency stop, stop category 1 (option+Q964) for
Brand:
ABB
| Category:
DC Drives
| Size: 1.01 MB
Table of Contents
Table of Contents
5
1 Safety Instructions
7
Contents of this Chapter
7
Use of Warnings and Notes
7
Instructions for Functional Safety Circuits
8
Electrical Safety Precautions
9
2 Introduction to the Manual
11
Contents of this Chapter
11
Applicability
11
Target Audience
11
Exclusion of Liability
11
Quick Reference Guide for Taking a Safety Function into Use
12
Terms and Abbreviations
12
3 Option Description
13
Contents of this Chapter
13
Overview
13
Operation Principle
14
Fault Reaction Function
15
Hardware Settings
16
4 Electrical Installation
17
Contents of this Chapter
17
Wiring
17
5 Parameter Settings
19
Contents of this Chapter
19
Drive Parameter Settings
19
Additional Parameter Settings for ACS880-07/07LC Drives, Frames N×Dxt + N×R8I and ACS880-17/17LC/37/37LC Drives, Frames N×R8I + N×R8I
20
6 Use of the Safety Function
21
Contents of this Chapter
21
Activating the Safety Function
21
Resetting the Safety Function
22
7 Start-Up and Validation Test
23
Contents of this Chapter
23
Validation of the Safety Functions
23
Competence
23
Validation Procedure
23
Validation Test Reports
24
Start-Up and Validation Test
24
8 Fault Tracing
27
Contents of this Chapter
27
Reporting Problems and Failures Related to Safety Functions
28
9 Maintenance
29
Contents of this Chapter
29
Safety Circuit Maintenance
29
Proof Test Interval
29
Competence
30
Residual Risk
30
Intentional Misuse
30
Decommissioning
30
10 Technical Data
31
Contents of this Chapter
31
Safety Data
31
Safety Data Values
31
Safety Component Types
32
Safety Block Diagrams
32
Relevant Failure Modes
32
Fault Exclusions
32
Operation Delays
33
Ambient Conditions
33
ACS880-07 Drives, Frames R6
33
Related Standards and Directives
33
Compliance with the European Machinery Directive
34
Further Information
35
ABB ACS880-37LC User Manual (36 pages)
Prevention of unexpected start-up (option +Q957)
Brand:
ABB
| Category:
DC Drives
| Size: 0.96 MB
Table of Contents
Table of Contents
5
Safety Instructions
7
Contents of this Chapter
7
Use of Warnings and Notes
7
Instructions for Functional Safety Circuits
7
Electrical Safety Precautions
8
Introduction to the Manual
11
Contents of this Chapter
11
Applicability
11
Target Audience
11
Exclusion of Liability
11
Quick Reference Guide for Taking a Safety Function into Use
12
Related Manuals
12
Terms and Abbreviations
14
Option Description
15
Contents of this Chapter
15
Overview
15
Operation Principle
16
Fault Reaction Function
17
Parameter Settings
17
Drive Parameter Settings
17
Additional Parameter Settings for ACS880-07 Drives, Frames Nxdxt + Nxr8I and ACS880-17/17LC/37/37LC Drives, Frames Nxr8I + Nxr8I
17
Hardware Settings
18
Electrical Installation
19
Contents of this Chapter
19
Wiring
19
Use of the Safety Function
21
Contents of this Chapter
21
Activating the Safety Function
21
Resetting the Safety Function
21
Start-Up and Acceptance Test
23
Contents of this Chapter
23
Validation of the Safety Functions
23
Competence
23
Validation Procedure
23
Acceptance Test Reports
24
Start-Up and Acceptance Test
24
Fault Tracing
27
Contents of this Chapter
27
Reporting Problems and Failures Related to Safety Functions
27
Maintenance
29
Contents of this Chapter
29
Safety Circuit Maintenance
29
Proof Test Interval
29
Competence
30
Residual Risk
30
Intentional Misuse
30
Decommissioning
30
Technical Data
31
Contents of this Chapter
31
ABB ACS880-37LC User Manual (68 pages)
Emergency stop, configurable stop category 0 or 1б option +Q979
Brand:
ABB
| Category:
Servo Drives
| Size: 1.27 MB
ABB ACS880-37LC User Manual (42 pages)
Emergency stop, stop category 1 (option+Q964) for drives
Brand:
ABB
| Category:
Industrial Equipment
| Size: 0.89 MB
Advertisement
Related Products
ABB ACS880-31
ABB ACS880-34-293A-3
ABB ACS880-34-505A-3
ABB ACS880-34-585A-3
ABB ACS880-34-650A-7
ABB ACS880-34-240A-5
ABB ACS880-34-302A-5
ABB ACS880-34-414A-5
ABB ACS880-34-142A-7
ABB ACS880-34-174A-7
ABB Categories
Industrial Equipment
Controller
Measuring Instruments
Battery Charger
DC Drives
More ABB Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL