ABB RET615 Manual (100 pages)
Transformer Protection and Control
Brand:
ABB
| Category:
Control Unit
| Size: 2.83 MB
Table of Contents
Table of Contents
7
Section 1 Introduction
13
This Manual
13
Intended Audience
13
Product Documentation
14
Product Documentation Set
14
Document Revision History
14
Related Documentation
15
Symbols and Conventions
15
Symbols
15
Document Conventions
15
Functions, Codes and Symbols
16
Section 2 Modbus Data Mappings
21
Overview
21
Supported Functions
21
Supported Functions in RET615
21
Indications
23
Premapped Indications
23
Common Data 1
23
CTRL.CBCILO1 Circuit Breaker Enable Signals (1)
24
CTRL.CBCSWI1 Circuit Breaker (1) Mom+MCD Position
24
CTRL.CBCSWI1 Circuit Breaker (1) Mom. Position
24
CTRL.CBXCBR1 Circuit-Breaker Control (1)
24
CTRL.DCSXSWI1 Disconnector Position Indication (1)
25
CTRL.DCSXSWI2 Disconnector Position Indication (2)
25
CTRL.DCSXSWI3 Disconnector Position Indication (3)
25
CTRL.DCXSWI1 Disconnector Control (1)
25
CTRL.DCXSWI2 Disconnector Control (2)
26
CTRL.ESSXSWI1 Earthing Switch Indication (1)
27
CTRL.ESSXSWI2 Earthing Switch Indication (2)
27
CTRL.ESXSWI1 Earthing Switch Control (1)
27
LD0.ARCSARC1 Arc Protection (1)
28
LD0.ARCSARC2 Arc Protection (2)
28
LD0.ARCSARC3 Arc Protection (3)
28
LD0.CCBRBRF1 Circuit Breaker Failure Protection (1)
28
LD0.CMMXU1 Three-Phase Current Measurement (1)
29
LD0.CMMXU2 Three-Phase Current Measurement (2)
29
LD0.DARREC1 Autoreclosing State (1)
29
LD0.EFHPTOC1 Non-Directional Earth-Fault Protection, High Stage (1)
30
LD0.EFHPTOC2 Non-Directional Earth-Fault Protection, High Stage (2)
30
LD0.EFLPTOC1 Non-Directional Earth-Fault Protection, Low Stage (1)
30
LD0.EFLPTOC2 Non-Directional Earth-Fault Protection, Low Stage (2)
30
LD0.HREFPDIF1 High-Impedance Based Restricted Earth-Fault Protection (1)
31
LD0.LEDGGIO1 Indication LED States Color1/Color2
31
LD0.LEDGGIO1 Indication LED States Off/Colorx
32
LD0.LEDPTRC1 Global Conditioning (1)
33
LD0.LEDPTRC1 Global Conditioning - Phase Information (1)
33
LD0.LREFPNDF1 Numerically Stabilized Low-Impedance Restricted Earth-Fault Protection (1)
34
LD0.MAPGAPC1 Multipurpose Protection (1)
34
LD0.MAPGAPC2 Multipurpose Protection (2)
34
LD0.MAPGAPC3 Multipurpose Protection (3)
35
LD0.MAPGAPC4 Multipurpose Protection (4)
35
LD0.MAPGAPC5 Multipurpose Protection (5)
35
LD0.MAPGAPC6 Multipurpose Protection (6)
35
LD0.MDSOPT1 Runtime Counter for Machines and Devices (1)
36
LD0.MVGAPC1 Move (8 Pcs) (1)
36
LD0.MVGAPC2 Move (8 Pcs) (2)
36
LD0.NSPTOC1 Negative-Sequence Overcurrent Protection (1)
37
LD0.NSPTOC2 Negative-Sequence Overcurrent Protection (2)
37
LD0.PHHPTOC1 Three-Phase Non-Directional Overcurrent Protection, High Stage (1)
38
LD0.PHHPTOC2 Three-Phase Non-Directional Overcurrent Protection, High Stage (2)
38
LD0.PHIPTOC1 Three-Phase Non-Directional Overcurrent Protection, Instantaneous Stage (1)
39
LD0.PHIPTOC2 Three-Phase Non-Directional Overcurrent Protection, Instantaneous Stage (2)
39
LD0.PHLPTOC1 Three-Phase Non-Directional Overcurrent Protection, Low Stage (1)
40
LD0.PHLPTOC2 Three-Phase Non-Directional Overcurrent Protection, Low Stage (2)
40
LD0.PHPTOV1 Three-Phase Overvoltage Protection (1)
41
LD0.PHPTOV2 Three-Phase Overvoltage Protection (2)
41
LD0.PHPTUV1 Three-Phase Undervoltage Protection (1)
41
LD0.PHPTUV2 Three-Phase Undervoltage Protection (2)
42
LD0.RESCMMXU1 Residual Current Measurement (1)
42
LD0.RESCMMXU2 Residual Current Measurement (2)
43
LD0.RESVMMXU1 Residual Voltage Measurement (1)
43
LD0.ROVPTOV1 Residual Overvoltage Protection (1)
43
LD0.ROVPTOV2 Residual Overvoltage Protection (2)
43
LD0.SEQSPVC1 Fuse Failure Supervision (1)
44
LD0.SPCGAPC2 Generic Control Point (16 Pcs) (2)
44
LD0.SSCBR1 Circuit-Breaker Condition Monitoring (1)
45
LD0.T2PTTR1 Three-Phase Thermal Overload Protection, Two Time Constants (1)
45
LD0.TCSSCBR1 Trip Circuit Supervision (1)
46
LD0.TCSSCBR2 Trip Circuit Supervision (2)
46
LD0.TR2PTDF1 Stabilized and Instantaneous Differential Protection for Two-Winding Transformers (1)
46
LD0.TRPPTRC1 Master Trip (1)
47
LD0.TRPPTRC2 Master Trip (2)
47
LD0.VMMXU1 Three-Phase Voltage Measurement (1)
47
LD0.XAGGIO130 Physical I/O States (AIM Card XA130)
48
LD0.XARGGIO130 Alarm/Warning
48
LD0.XBGGIO110 Physical I/O States (BIO Card XB110)
48
LD0.XGGIO100 Physical I/O States (PSM Card X100)
49
LD0.XGGIO110 Physical I/O States (BIO Card X110)
50
LD0.XGGIO130 Physical I/O States (BIO Card X130)
51
LD0.XRGGIO130 Alarm/Warning
52
Unmapped Indications
52
All Premapped Three-Phase Protection Function Stages, Operate/Phase-Dependent Objects Added
52
Common Data 2
53
LD0.DIAGLCCH1 Ethernet Supervision (1)
53
LD0.IL1TCTR1 Three-Phase CT Supervision (1)
54
LD0.IL1TCTR2 Three-Phase CT Supervision (2)
54
LD0.LDPRLRC1 Load Profile Record (1)
54
LD0.MAPGAPC7 Multipurpose Protection (7)
54
LD0.MAPGAPC10 Multipurpose Protection (10)
55
LD0.MAPGAPC11 Multipurpose Protection (11)
55
LD0.MAPGAPC8 Multipurpose Protection (8)
55
LD0.MAPGAPC9 Multipurpose Protection (9)
55
LD0.MAPGAPC12 Multipurpose Protection (12)
56
LD0.MAPGAPC13 Multipurpose Protection (13)
56
LD0.MAPGAPC14 Multipurpose Protection (14)
56
LD0.MAPGAPC15 Multipurpose Protection (15)
56
LD0.MAPGAPC16 Multipurpose Protection (16)
57
LD0.MAPGAPC17 Multipurpose Protection (17)
57
LD0.MAPGAPC18 Multipurpose Protection (18)
57
LD0.RESTCTR1 Io CT Supervision (1)
57
LD0.RESTCTR2 Io CT Supervision (2)
58
LD0.RESTVTR1 Uo VT Supervision (1)
58
LD0.SPCGAPC1 Generic Control Point (16 Pcs) (1)
58
LD0.TRPPTRC3 Master Trip (3)
59
LD0.TRPPTRC4 Master Trip (4)
59
LD0.TRPPTRC5 Master Trip (5)
60
LD0.UL1TVTR1 Three-Phase VT Supervision (1)
60
Registers
60
Premapped Registers
61
Active Parameter Setting Group - Read and Write
61
Control Structure 1
61
Control Structure 2
61
Control Structure 3
61
Control Structure 4
62
Control Structure 5
62
Control Structure 6
62
Control Structure 7
62
Control Structure 8
63
Device ID String
63
Event Record Structure
63
Fault Record Data
67
Fault Record Structure Header
67
Protection Relay's Real-Time Clock (in Local Time Mode) - Read and Write (Synchronize)
71
Protection Relay's Real-Time Clock (in UTC Time Mode) - Read and Write (Synchronize)
71
Indication Bits Mirrored in Registers
72
SSR1 System Status Register (1) Device Health
72
SSR2 System Status Register (2) Protection Relay's Mode and State
73
SSR3 System Status Register (3) Data Available 1 (Client-Dependent)
73
SSR4 System Status Register (4) Data Available 2 (Client-Dependent, User-Definable)
74
SSR5 System Status Register (5) Device Alive Register
74
SSR6 System Status Register (6) Control Command Status (Client-Dependent)
75
System Diagnostic Values
75
Time and Reason for Latest Protection Relay Reset
76
User-Definable Bits [Alt.2], Visible on 0X,1X,3X and 4X
76
CTRL.CBCSWI1 Circuit Breaker Operation Counter (1)
77
Ld0.Arcsarcx1 Arc Protection
77
LD0.CMMXU1 Phase Current Demand Values (1)
77
User-Definable Registers [Alt.1], Visible on 3X and 4X
77
LD0.CMMXU1 Three-Phase Current Measurement (1)
79
LD0.CMMXU2 Phase Current Demand Values (2)
79
LD0.CMMXU2 Three-Phase Current Measurement (2)
80
LD0.CSMSQI1 Sequence Current Measurement (1)
80
LD0.PEMMTR1 Three-Phase Energy Measurements
81
LD0.PEMMXU1 Power Measurement Demand Values (1)
81
LD0.PEMMXU1 Three-Phase Power and Energy Measurement (1)
82
LD0.RESCMMXU1 Residual Current Demand Value (1)
82
LD0.RESCMMXU1 Residual Current Measurement (1)
83
LD0.RESCMMXU2 Residual Current Demand Value (2)
83
LD0.RESCMMXU2 Residual Current Measurement (2)
83
LD0.RESVMMXU1 Residual Voltage Demand Value (1)
84
LD0.RESVMMXU1 Residual Voltage Measurement (1)
84
LD0.SSCBR1 Circuit-Breaker Condition Monitoring (1)
84
LD0.T2PTTR1 Three-Phase Thermal Overload Protection, Two Time Constants (2)
85
LD0.TPOSYLTC1 Tap Changer Position Indication (1)
85
LD0.TR2PTDF1 Stabilized and Instantaneous Differential Protection for Two-Winding Transformers (1)
85
LD0.VMMXU1 Three-Phase Voltage Measurement (1)
86
LD0.VMMXU1 Voltage Demand Values (1)
86
LD0.VSMSQI1 Sequence Voltage Measurement (1)
87
LD0.XARGGIO130 RTD Input Values
87
LD0.XRGGIO130 RTD Input Values
87
Unmapped Registers
87
CTRL.LLN0 Local, Remote, Station, off and Combinations
88
LD0.FMMXU1 Frequency Measurement (1)
88
LD0.LLN0/LPHD1/LDEV1 System Values
88
LD0.MDSOPT1 Runtime Counter for Machines and Devices (1)
88
LD0.MVI4GAPC1 Integer Value Move (1)
88
LD0.SCA4GAPC1 Analog Value Scaling (1)
89
LD0.SCA4GAPC2 Analog Value Scaling (2)
89
LD0.SCA4GAPC3 Analog Value Scaling (3)
89
LD0.SCA4GAPC4 Analog Value Scaling (4)
90
Controls
90
Reset, Acknowledge and Trigger Points
90
CTRL.CBCSWI1 Circuit Breaker Control (1)
91
CTRL.DCXSWI1 Disconnector Control (1)
91
CTRL.DCXSWI2 Disconnector Control (2)
92
CTRL.ESXSWI1 Earthing Switch Control (1)
92
LD0.LDEV1 Protection Relay's Warm Reset (1)
92
LD0.SPCGAPC1 Generic Control Point (16 Pcs) (1)
93
LD0.SPCGAPC2 Generic Control Point (16 Pcs) (2)
93
LD0.SRGAPC1 Set-Reset (8 Pcs) (1)
94
LD0.SRGAPC2 Set-Reset (8 Pcs) (2)
94
Unmapped Control Points
95
Section 3 Glossary
97
Advertisement
ABB RET615 Manual (56 pages)
Transformer Protection and Control DNP3 Point List
Brand:
ABB
| Category:
Power distribution unit
| Size: 2.55 MB
Table of Contents
Table of Contents
7
Section 1 Introduction
11
This Manual
11
Intended Audience
11
Product Documentation
11
Product Documentation Set
11
Document Revision History
12
Related Documentation
12
Symbols and Conventions
13
Symbols
13
Document Conventions
13
Functions, Codes and Symbols
14
Section 2 DNP3 Data Mappings
17
Overview
17
Supported Functions
17
Point List for RET615 Ver.4.0 TE01-08
19
Binary Inputs
19
LD0.ARCSARC1 Fault Arc Protection Stage 1
19
LD0.ARCSARC2 Fault Arc Protection Stage 2
20
LD0.ARCSARC3 Fault Arc Protection Stage 3
20
Ctrl.cxxxxx1 Circuit Breaker (1) CB Object and Failure Protection
20
Ctrl.dxxxxx1 Controllable Disconnector (1)
21
Ctrl.dxxxxx2 Controllable Disconnector (2)
21
Ctrl.exxxxx1 Controllable Earth Switch (1)
21
LD0.CMMXU1 Phase Currents (1) Limit Supervision
22
LD0.CMMXU2 Phase Currents (2) Limit Supervision
22
LD0.EFHPTOC1 Non-Directional Earth-Fault and Sensitive Earth-Fault Protection - High Stage 1
22
LD0.EFHPTOC2 Non-Directional Earth-Fault and Sensitive Earth-Fault Protection - High Stage 2
22
LD0.EFLPTOC1 Non-Directional Earth-Fault and Sensitive Earth-Fault Protection - Low Stage 1
23
LD0.EFLPTOC2 Non-Directional Earth-Fault and Sensitive Earth-Fault Protection - Low Stage 2
23
LD0.HREFPDIF1 High-Impedance Restricted Earth-Fault Protection (1)
23
LD0.LEDGGIO1 LHMI LED Indications
23
LD0.LEDPTRC1 Global Protection Signals
24
CTRL.LLN0 Local/Remote State (also Present in DNP IIN-Bits)
24
LD0.LLN0 Settings Supervision
24
LD0.LREFPDIF1 Low-Impedance Restricted Earth-Fault Protection (1)
24
LD0.MAPGAPC1 Multipurpose Analog Protection Function (1)
25
LD0.MAPGAPC2 Multipurpose Analog Protection Function (2)
25
LD0.MAPGAPC3 Multipurpose Analog Protection Function (3)
25
LD0.MAPGAPC4 Multipurpose Analog Protection Function (4)
25
LD0.MAPGAPC5 Multipurpose Analog Protection Function (5)
25
LD0.MAPGAPC6 Multipurpose Analog Protection Function (6)
26
LD0.MDSOPT1 Generic Operation Time Supervision
26
LD0.MVGAPC1 Multipurpose Binary Inputs (1)
26
LD0.MVGAPC2 Multipurpose Binary Inputs (2)
26
LD0.NSPTOC1 Negative-Sequence Overcurrent Protection (1)
27
LD0.NSPTOC2 Negative-Sequence Overcurrent Protection (2)
27
LD0.PHHPTOC1 Phase Overcurrent Protection - High Stage 1
27
LD0.PHHPTOC2 Phase Overcurrent Protection - High Stage 2
27
LD0.PHIPTOC1 Phase Overcurrent Protection - Instantaneous Stage 1
28
LD0.PHIPTOC2 Phase Overcurrent Protection - Instantaneous Stage 2
28
LD0.PHLPTOC1 Phase Overcurrent Protection - Low Stage 1
28
LD0.PHLPTOC2 Phase Overcurrent Protection - Low Stage 2
28
LD0.PHPTOV1 Phase Overvoltage Protection - Stage 1
28
LD0.PHPTOV2 Phase Overvoltage Protection - Stage 2
29
LD0.PHPTUV1 Phase Undervoltage Protection - Stage 1
29
LD0.PHPTUV2 Phase Undervoltage Protection - Stage 2
29
DR.RDRE1 Disturbance Recorder
29
LD0.RESCMMXU1 Residual Current Limit Supervision
29
LD0.RESCMMXU2 Residual Current Limit Supervision
30
LD0.RESVMMXU1 Residual Voltage Limit Supervision
30
LD0.ROVPTOV1 Residual Overvoltage Protection (1)
30
LD0.ROVPTOV2 Residual Overvoltage Protection (2)
30
LD0.SEQRFUF1 Fuse Failure Protection
30
LD0.SPCGGIO2 Multipurpose Binary Outputs - Status (2)
31
LD0.SSCBR1 Circuit-Breaker Condition Monitoring
31
LD0.T2PTTR1 Thermal Protection (2)
32
LD0.TCSSCBR1 Trip Circuit Supervision (1)
32
LD0.TCSSCBR2 Trip Circuit Supervision (2)
32
LD0.TR2PDIF1 Transformer Differential Protection
32
LD0.TRPPTRC1 Global Conditioning (1)
32
LD0.TRPPTRC2 Global Conditioning (2)
33
LD0.VMMXU1 Three-Phase Voltage Limit Supervision
33
LD0.XRGGIO130 Alarm/Warning
33
LD0.XAGGIO130 Physical I/O
33
LD0.XGGIO100 Physical I/O
34
LD0.XGGIO110 Physical I/O
34
LD0.XGGIO130 Physical I/O
34
Binary Outputs
35
CTRL.CBCSWI1 Circuit Breaker Control
35
CTRL.DCCSWI1 Controllable Disconnector (1) Control
35
CTRL.DCCSWI2 Controllable Disconnector (2) Control
35
CTRL.ESCSWI2 Controllable Earth Switch (1) Control
36
LD0.DNPGGIO1 Parameter Setting Group Control
36
LD0.LLN0/LPHD1 Reset Indications and Leds, Reset Device
36
LD0.PEMMXU1 Reset Accumulated Energy Values
36
DR.RDRE1 Disturbance Recorder
37
LD0.SPCGGIO1 Multipurpose Binary Outputs (1)
37
LD0.SPCGGIO2 Multipurpose Binary Outputs (2)
37
LD0.SRGAPC1 Multipurpose Binary Outputs - Flip-Flop Resets (1)
38
LD0.SRGAPC2 Multipurpose Binary Outputs - Flip-Flop Resets (2)
39
LD0.SSCBR1 Reset Signals of CB Condition Monitoring
39
Analog Inputs
39
CTRL.CBCSWI1 CB 4-Pole (2 Bit) Position Value
40
LD0.CMMXU1 Phase Currents (1)
40
LD0.CMMXU2 Phase Currents (2)
40
LD0.CSMSQI1 Sequence of Currents
40
CTRL.DCSXSWI1 Disconnector 1, 4-Pole (2 Bit) Position Values
40
CTRL.DCSXSWI2 Disconnector 2, 4-Pole (2 Bit) Position Values
41
CTRL.DCSXSWI3 Disconnector 3, 4-Pole (2 Bit) Position Values
41
CTRL.DCXSWI1 Controllable Disconnector 1, 4-Pole (2 Bit) Position Values
41
CTRL.DCXSWI2 Controllable Disconnector 2, 4-Pole (2 Bit) Position Values
41
CTRL.ESSXSWI1 Earth Switch 1, 4-Pole (2 Bit) Position Values
41
CTRL.ESSXSWI2 Earth Switch 2, 4-Pole (2 Bit) Position Values
42
CTRL.ESXSWI1 Controllable Earth Switch 1, 4-Pole (2 Bit) Position Values
42
LD0.DNPGGIO1 Active Parameter Setting Group
42
CTRL.LLN0 Local Remote Station off
42
LD0.LPHD1 System Values
42
LD0.PEMMTR1 Power Measurement and Accumulated Power Values
43
DR.RDRE1 Disturbance Recorder Values
43
LD0.RESCMMXU1 Residual Current (1)
43
LD0.RESCMMXU2 Residual Current (2)
43
LD0.RESVMMXU1 Residual Voltage (1)
44
LD0.T2PTTR1 Temperature Protection Values (2)
44
LD0.TPOSSLTC1 Tap Changer Position Value
44
LD0.VMMXU1 Voltage Measurement
44
LD0.VSMSQI1 Sequence of Voltage Measurement
45
LD0.XRGGIO130 RTD Inputs
45
Section 3 DNP3 Protocol Implementation
47
DNP3 Device Profile
47
DNP3 Implementation Table
49
Section 4 Glossary
53
ABB RET615 Manual (52 pages)
Transformer Protection and Control
Brand:
ABB
| Category:
Transformer
| Size: 2.83 MB
Table of Contents
Table of Contents
7
Section 1 Introduction
11
This Manual
11
Intended Audience
11
Product Documentation
11
Product Documentation Set
11
Document Revision History
12
Related Documentation
12
Symbols and Conventions
13
Symbols
13
Document Conventions
13
Functions, Codes and Symbols
14
Section 2 IEC 60870-5-103 Data Mappings
17
Overview
17
Supported Functions
17
Point List for RET615 Ver.4.0 TE01-08
19
Indications and Controls
19
General Data(FUN=0) IEC 60870-5-103 Standard
19
General Data(FUN=10) - 615-Specific
20
Generaldata(10-2) - 615-Specific
21
LD0.MVGAPC1 Multipurpose Binary Inputs (1)
21
LD0.MVGAPC2 Multipurpose Binary Inputs (2)
21
LD0.SRGAPC1 Multipurpose Binary Outputs - Flip-Flop Resets (1)
22
LD0.SRGAPC2 Multipurpose Binary Outputs - Flip-Flop Resets (2)
22
LD0.SPCGGIO1 Multipurpose Binary Outputs (1)
22
LD0.SPCGGIO2 Multipurpose Binary Outputs (2)
23
LD0.NSPTOC1 Negative-Sequence Overcurrent Protection (1)
24
LD0.NSPTOC2 Negative-Sequence Overcurrent Protection (2)
24
LD0.SEQRFUF1 Fuse Failure Protection
24
LD0.TPOSSLTC1 Tap Position
24
LD0.MAPGAPC1 Multipurpose Analog Protection Function (1)
24
LD0.MAPGAPC2 Multipurpose Analog Protection Function (2)
25
LD0.MAPGAPC3 Multipurpose Analog Protection Function (3)
25
LD0.MAPGAPC4 Multipurpose Analog Protection Function (4)
25
LD0.MAPGAPC5 Multipurpose Analog Protection Function (5)
25
LD0.MAPGAPC6 Multipurpose Analog Protection Function (6)
25
LD0.XRGGIO130 Alarm and Warning
26
LD0.PHPTOV3 Phase Overvoltage Protection - Stage 3
26
LD0.PHPTOV2 Phase Overvoltage Protection - Stage 2
26
LD0.PHPTOV1 Phase Overvoltage Protection - Stage 1
26
LD0.PHPTUV3 Phase Undervoltage Protection - Stage 3
27
LD0.PHPTUV2 Phase Undervoltage Protection - Stage 2
27
LD0.PHPTUV1 Phase Undervoltage Protection - Stage 1
27
LD0.ROVPTOV1 Residual Overvoltage Protection - Stage 1
27
LD0.ROVPTOV2 Residual Overvoltage Protection - Stage 2
28
LD0.ROVPTOV3 Residual Overvoltage Protection - Stage 3
28
LD0.XGGIO130 Physical Binary I/O Signals (Status Only)
28
LD0.XGGIO120 Physical Binary I/O Signals (Status Only)
28
LD0.XGGIO110 Physical Binary I/O Signals (Status Only)
29
LD0.XGGIO100 Physical Binary I/O Signals (Status Only)
29
LD0.MDSOPT1 Generic Operation Time Supervision
29
LD0.ARCSARC1 Fault Arc Protection - Stage 1
30
LD0.ARCSARC2 Fault Arc Protection - Stage 2
30
LD0.ARCSARC3 Fault Arc Protection - Stage 3
30
LD0.EFLPTOC1 Non-Directional Earth-Fault and Sensitive Earth-Fault Protection - Low Stage 1
30
LD0.EFLPTOC2 Non-Directional Earth-Fault and Sensitive Earth-Fault Protection - Low Stage 2
31
LD0.PHIPTOC2 Phase Overcurrent Protection
31
Instantaneous Stage 2
31
LD0.PHIPTOC1 Phase Overcurrent Protection - Instantaneous Stage 1
31
LD0.PHHPTOC2 Phase Overcurrent Protection - High Stage 2
31
LD0.PHHPTOC1 Phase Overcurrent Protection - High Stage 1
32
LD0.PHLPTOC1 Phase Overcurrent Protection - Low Stage 1
32
LD0.PHLPTOC2 Phase Overcurrent Protection - Low Stage 2
32
LD0.T2PTTR1 Thermal Overload Protection (2)
32
LD0.LREFPDIF1 Low-Impedance Restricted Earth-Fault Protection (1)
33
LD0.HREFPDIF1 High-Impedance Restricted Earth-Fault Protection (1)
33
LD0.TR2PDIF1 Transformer Differential Protection
33
LD0.CMMXU1 Phase Currents (1) Limit Supervision
33
LD0.RESCMMXU1 Residual Current (1) Limit Supervision
33
LD0.CMMXU2 Phase Currents (2) Limit Supervision
34
LD0.RESCMMXU2 Residual Current (2) Limit Supervision
34
Ctrl.cxxxxx1 Circuit Breaker (1) CB Object and Failure Protection
34
LD0.SSCBR1 Circuit Breaker (1) Condition Monitoring
35
CTRL.DCXSWI1 Disconnector (1) - Controllable Object
35
CTRL.DCXSWI2 Disconnector (2) - Controllable Object
36
CTRL.ESXSWI1 Earth Switch - Controllable Object
36
CTRL.DCSXSWI1 Disconnector (1) - Non-Controllable Object
36
CTRL.DCSXSWI2 Disconnector (2) - Non-Controllable Object
37
CTRL.DCSXSWI3 Disconnector (3) - Non-Controllable Object
37
CTRL.ESSXSWI1 Earth Switch (1) - Non-Controllable Object
37
CTRL.ESSXSWI2 Earth Switch (2) - Non-Controllable Object
37
LD0.LEDGGIO1 LHMI LED Indications
37
Class 2 Data Measurands
38
Class 2 Private Measurand Data (6 and 7) for RET615
39
Section 3 Interoperability Profile for 615 Series IEC 60870-5-103
43
Physical Layer
43
Electrical Interface
43
Optical Interface
43
Transmission Speed
43
Link Layer
43
Application Layer
44
Transmission Mode for Application Data
44
COMMON ADDRESS of ASDU
44
Selection of Standard Information Numbers in Monitor Direction
44
System Functions in Monitor Directions
44
Status Indications in Monitor Direction
44
Supervision Indications in Monitor Direction
45
Earth Fault Indications in Monitor Direction
45
Fault Indications in Monitor Direction
45
Auto-Reclosure Indications in Monitor Direction
46
Measurands in Monitor Direction
47
Generic Functions in Monitor Direction
47
Selection of Standard Information Numbers in Control Direction
47
System Functions in Control Direction
47
Basic Application Functions
48
Miscellaneous
48
Section 4 Glossary
49
Advertisement
ABB RET615 Product Manual (64 pages)
Transformer Protection and Control
Brand:
ABB
| Category:
Protection Device
| Size: 5.21 MB
Table of Contents
Table of Contents
2
Description
3
Standard Configurations
3
Protection Functions
14
Application
15
Supported ABB Solutions
18
Control
19
Measurements
20
Disturbance Recorder
20
Event Log
20
Recorded Data
20
Condition Monitoring
21
Trip-Circuit Supervision
21
Self-Supervision
21
Fuse Failure Supervision
22
Access Control
22
Inputs and Outputs
22
Station Communication
22
Technical Data
28
Local HMI
51
Mounting Methods
52
Relay Case and Plug-In Unit
52
Selection and Ordering Data
52
Accessories and Ordering Data
53
Tools
54
Cyber Security
55
Terminal Diagrams
56
Certificates
58
References
58
Functions, Codes and Symbols
59
Document Revision History
62
ABB RET615 Product Manual (68 pages)
Relion 615 series. Transformer Protection and Control
Brand:
ABB
| Category:
Protection Device
| Size: 6.7 MB
Table of Contents
Description
3
Protections Functions
7
Application
16
Supported ABB Solutions
18
Control
19
Measurement
20
Event Log
21
Station Communication
22
Technical Data
25
Local HMI
50
Mounting Methods
51
IED Case and IED Plug-In Unit
52
Accessories and Ordering Data
56
Tools
57
Terminal Diagrams
59
Certificates
61
Functions, Codes and Symbols
62
Document Revision History
64
ABB RET615 Product Manual (53 pages)
Relion 615 series. Transformer Protection and Control
Brand:
ABB
| Category:
Protection Device
| Size: 3.89 MB
Table of Contents
Description
3
Protections Functions
6
Application
9
Supported ABB Solutions
11
Control
13
Circuit-Breaker Monitoring
14
Communication
15
Technical Data
17
Display Options
38
Mounting Methods
39
Selection and Ordering Data
40
Accessories and Ordering Data
44
Terminal Diagrams
46
References
47
Functions, Codes and Symbols
48
Document Revision History
50
ABB RET615 Manual (40 pages)
Transformer Protection and Control
Brand:
ABB
| Category:
Relays
| Size: 1.66 MB
Table of Contents
Table of Contents
7
Section 1 Introduction
9
This Manual
9
Intended Audience
9
Product Documentation
10
Product Documentation Set
10
Document Revision History
11
Related Documentation
12
Symbols and Conventions
12
Safety Indication Symbols
12
Manual Conventions
12
Functions, Codes and Symbols
13
Section 2 DNP3 Data Mappings
17
Overview
17
Point List for RET615 Ver.3.0 TE01-08
18
Section 3 DNP3 Protocol Implementation
29
DNP3 Device Profile
29
DNP3 Implementation Table
31
Section 4 Glossary
35
ABB RET615 Manual (40 pages)
Transformer Protection and Control
Brand:
ABB
| Category:
Industrial Equipment
| Size: 1.67 MB
Table of Contents
Table of Contents
7
Section 1 Introduction
9
This Manual
9
Intended Audience
9
Product Documentation
10
Product Documentation Set
10
Document Revision History
11
Related Documentation
12
Symbols and Conventions
12
Safety Indication Symbols
12
Manual Conventions
12
Functions, Codes and Symbols
13
Section 2 DNP3 Data Mappings
17
Overview
17
Section 3 DNP3 Protocol Implementation
31
DNP3 Device Profile
31
DNP3 Implementation Table
33
Section 4 Glossary
37
Advertisement
Related Products
ABB RELION RET670
ABB RET650 2.1 IEC
ABB RET630
ABB RET650 2.2
ABB RET 670
ABB RET670 ANSI
ABB REJ601
ABB Relion REQ650
ABB REF611
ABB REG670 A20
ABB Categories
Industrial Equipment
Controller
Measuring Instruments
Battery Charger
DC Drives
More ABB Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL