User Manuals: ABB RET650 A05A 3W/1CB Protection Device
Manuals and User Guides for ABB RET650 A05A 3W/1CB Protection Device. We have
1
ABB RET650 A05A 3W/1CB Protection Device manual available for free PDF download: Commissioning Manual
ABB RET650 A05A 3W/1CB Commissioning Manual (112 pages)
Relion 650 SERIES Transformer protection
Brand:
ABB
| Category:
Control Unit
| Size: 3.15 MB
Table of Contents
Table of Contents
7
Introduction
13
Intended Audience
13
This Manual
13
Product Documentation
14
Product Documentation Set
14
Document Revision History
15
Related Documents
15
Document Conventions
16
Safety Information
19
Symbols
16
Symbols and Conventions
16
Symbols on the Product
19
Warnings
19
Caution Signs
20
Note Signs
21
Available Functions
23
Back-Up Protection Functions
23
Main Protection Functions
23
Control and Monitoring Functions
24
Station Communication
28
Basic IED Functions
30
Starting up
31
Commissioning Checklist
31
Factory and Site Acceptance Testing
31
Checking the IED Operation
32
Checking the Power Supply
32
Energizing the IED
32
IED Start-Up Sequence
32
Setting up Communication between PCM600 and the IED
33
Writing an Application Configuration to the IED
38
Checking CT Circuits
39
Checking VT Circuits
39
Using the RTXP Test Switch
40
Binary Input Circuits
41
Binary Output Circuits
41
Checking Binary Input and Output Circuits
41
Checking Optical Connections
41
Establishing Connection and Verifying the IEC 61850 Station Communication
43
Setting the Station Communication
43
Verifying the Station Communication
43
Testing IED Operation
45
Preparing the IED to Verify Settings
45
Activating the Test Mode
46
Connecting the Test Equipment to the IED
47
Preparing the Connection to the Test Equipment
47
Releasing the Function to be Tested
48
Verifying Analog Primary and Secondary Measurement
49
Testing the Protection Functionality
50
Testing Functionality
51
Disturbance Report Settings
51
Identifying the Function to Test in the Technical Reference Manual
51
Introduction
51
Testing Differential Protection Functions
51
Testing Disturbance Report
51
Transformer Differential Protection T2WPDIF (87T) and T3WPDIF (87T)(87T)
51
Completing the Test
52
Verifying the Settings
52
Completing the Test
53
Restricted Earth-Fault Protection, Low Impedance REFPDIF (87N)
53
Verifying the Settings
53
Completing the Test
54
High Impedance Differential Protection HZPDIF (87)
54
Verifying the Settings
54
Completing the Test
55
Instantaneous Phase Overcurrent Protection 3-Phase Output PHPIOC (50)
55
Measuring the Operate Limit of Set Values
55
Testing Current Protection Functions
55
Four Step Phase Overcurrent Protection 3-Phase Output OC4PTOC (51_67)
56
Verifying the Settings
56
Completing the Test
57
Four Step Residual Overcurrent Protection, Zero or Negative Sequence Direction EF4PTOC (51N/67N)
57
Instantaneous Residual Overcurrent Protection EFPIOC (50N)
57
Measuring the Operate Limit of Set Values
57
Completing the Test
58
Four Step Directional Residual Overcurrent Protection
58
Four Step Non-Directional Residual Overcurrent Protection
58
Thermal Overload Protection, Two Time Constants TRPTTR (49)
58
Checking Operate and Reset Values
59
Completing the Test
59
Breaker Failure Protection, Phase Segregated Activation and Output CCRBRF (50BF)
60
Checking the Phase Current Operate Value, Pickup_Ph
60
Checking the Residual (Ground Fault) Current Operate Value Pickup_N Set below
60
Pickup_Ph
60
Checking the Re-Trip and Back-Up Times
61
Verifying the Re-Trip Mode
61
Verifying the Back-Up Trip Mode
62
Verifying the Case Retripmode = Contact
62
Completing the Test
63
Verifying the Function Mode Current&Contact
63
Completing the Test
64
Directional Underpower Protection GUPPDUP (37)
64
Pole Discrepancy Protection CCRPLD (52PD)
64
Verifying the Settings
64
Completing the Test
66
Directional Overpower Protection GOPPDOP (32)
66
Verifying the Settings
66
Completing the Test
67
Testing Voltage Protection Functions
67
Two Step Undervoltage Protection UV2PTUV (27)
67
Verifying the Setting
67
Completing the Test
69
Two Step Overvoltage Protection OV2PTOV (59)
69
Verification of Single-Phase Voltage and Time Delay to Operate for Step 1
69
Completing the Test
70
Two Step Residual Overvoltage Protection ROV2PTOV (59N)
70
Verifying the Settings
70
Completing the Test
71
Overexcitation Protection OEXPVPH (24)
71
Verifying the Settings
71
Completing the Test
72
Testing Frequency Protection Functions
72
Underfrequency Protection SAPTUF (81)
72
Verifying the Settings
72
Completing the Test
74
Overfrequency Protection SAPTOF (81)
74
Verifying the Settings
74
Completing the Test
75
Rate-Of-Change Frequency Protection SAPFRC (81)
75
Verifying the Settings
75
Checking that the Binary Inputs and Outputs Operate as Expected
76
Completing the Test
76
Fuse Failure Supervision SDDRFUF
76
Testing Secondary System Supervision Functions
76
Measuring the Operate Value for the Negative Sequence Function
77
Measuring the Operate Value for the Zero-Sequence Function
78
Checking the Operation of the DV/Dt and DI/Dt Based Function
79
Completing the Test
79
Interlocking
79
Testing Control Functions
79
Apparatus Control APC
80
Voltage Control
80
Check the Activation of the Voltage Control Operation
82
Secondary Test
82
Check the Normal Voltage Regulation Function
83
Check the Overcurrent Block Function
83
Check the Undervoltage Block Function
83
Check the Upper and Lower Busbar Voltage Limit
83
Automatic Voltage Control for Tap Changer, Parallel Control TR8ATCC
84
Completing the Test
87
Testing Logic Functions
87
Testing Scheme Communication Functions
87
Tripping Logic, Common 3-Phase Output SMPPTRC (94)
87
Circuit Breaker Lockout
88
Completing the Test
88
Event Counter CNTGGIO
88
Testing Monitoring Functions
88
Three-Phase Operating Mode
88
Completing the Test
89
Establishing Connection and Verifying the IEC 61850 Communication
89
Limit Counter L4UFCNT
89
Overview
89
Pulse Counter PCGGIO
89
Testing Metering Functions
89
Testing Station Communication
89
Setting the Station Communication
90
Verifying the Station Communication
90
Exit Test Mode
91
Commissioning and Maintenance of the Fault Clearing System
93
Commissioning Tests
93
Periodic Maintenance Tests
93
Maintenance Tests
94
Troubleshooting
97
Visual Inspection
94
Checking the Communication Link Operation
97
Fault Tracing
97
Identifying Communication Errors
97
Identifying Hardware Errors
97
Identifying Runtime Errors
97
Checking the Time Synchronization
98
Indication Messages
98
Internal Faults
98
Running the Display Test
98
Warnings
99
Additional Indications
100
Changing and Setting the Password
100
Correction Procedures
100
Identifying IED Application Problems
100
Inspecting the Wiring
100
Glossary
105
Advertisement
Advertisement
Related Products
ABB RET650 A01A 2W/1CB
ABB RET650 A07A OLTC
ABB REC650 ANSI
ABB RELION REC650
ABB Relion 630 Series
ABB RELION Series
ABB RER 103
ABB RER103-BM
ABB RER103-MB
ABB RER 133
ABB Categories
Industrial Equipment
Controller
Measuring Instruments
Battery Charger
DC Drives
More ABB Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL