Sign In
Upload
Manuals
Brands
Hitachi Manuals
Storage
HUS151414VL3800
Hitachi HUS151414VL3800 Manuals
Manuals and User Guides for Hitachi HUS151414VL3800. We have
2
Hitachi HUS151414VL3800 manuals available for free PDF download: Specifications, Quick Installation Manual
Hitachi HUS151414VL3800 Specifications (321 pages)
3.5 inch SCSI Hard Disk Drive
Brand:
Hitachi
| Category:
Storage
| Size: 2.12 MB
Table of Contents
Table of Contents
5
List of Tables
13
1 General
19
Introduction
19
Glossary
19
Caution
19
2 Outline of the Drive
21
3 Fixed-Disk Subsystem Description
23
Control Electronics
23
Head Disk Assembly
23
Actuator
23
4 Drive Characteristics
25
Formatted Capacity
25
Data Sheet
25
Table 1. Formatted Capacity
25
Table 2. Data Sheet
25
Inquiry Information
26
Product ID
26
Table 3. Product ID in Inquiry Command
26
Worldwide ID - Block Assignment
27
Table 4. Block Assignment of Worldwide ID in INQUIRY Command
27
Cylinder Allocation
28
Performance Characteristics
28
Table 5. Cylinder Allocation
28
Mechanical Positioning
29
Table 6. Mechanical Positioning Performance
29
Appendix
30
Average Latency
30
Table 7. Full Stroke Seek Time
30
Table 8. Latency Time
30
Data Transfer Speed
31
Drive Ready Time
31
Spindle Stop Time
31
Table 10. Spindle Stop Time
31
Table 11. Data Transfer Speed (Sector Size 512 Byte Case)
31
Table 9. Drive Ready Time
31
Buffering Operation (Read Ahead/Write Cache)
32
Table 12. Simple Sequential Access Performance (Sector Size 512 Byte Case)
32
Throughput
32
Table 13. Random Access Performance (Sector Size 512 Byte Case)
33
5 Data Integrity
35
Equipment Status
35
Error Recovery Procedure
35
6 Physical Format
37
Shipped Format (Plist)
37
Reassigned Format (Glist)
37
7 Electrical Interface Specification
39
Power Connector
39
SCSI Bus Connector
40
SCSI Signal Connector (68-Pin Model)
40
Table 14. Table of Signals (68-Pin)
40
SCSI Signal Connector (80-Pin SCA-2 Model)
41
Table 15. Table of Signals (80-Pin)
41
SCSI Cable
42
SCSI Bus Terminator
42
Hot Plug/Unplug
42
SCSI Bus Electrical Characteristics
42
Auxiliary Connector on 68-Pin Model
43
Option Jumper Block
44
Jumper Signal Description on 80 Pin Jumper Block
45
Disable Auto Spin (Position 1-2)
45
Auto Spin Delay and Delay Spin 12 / 6 (Position 3-4)
45
Force Single Ended Mode (Position 7-8)
45
Reserved (Position 9-10)
45
Table 16. Auto Start Delay & Delay Start 6/12 Drive Behavior
45
LED Driver out (Position 11-12)
46
Positions #13-14
46
Jumper Signal Description on 68 Pin Jumper Block
47
LED Driver out (Position 1-2)
47
Enable Termination Power (Positions 3-4)
47
Force Single Ended Mode (Position 5-6)
47
Positions #7-8 to #13-14: Device ID
47
Table 17. SCSI Device ID
47
Jumper Signal Description on 68 Pin Jumper Block (J6)
48
Disable Auto Spin (Position 1-2)
48
Auto Spin Delay and Delay Spin 12 / 6 (Position 3-4 and 5-6)
48
Disable Parity (Position 7-8)
48
Disable Unit Attention (Position 11-12)
48
Reserved (Positions 9-10 and 13-14)
48
8 Environment
49
Temperature and Humidity
49
Table 18. Operating and Non-Operating Conditions
49
Storage Requirements
50
Packaging
50
Storage Time
50
Corrosion Test
50
Cooling Requirements
51
Table 19. Maximum Allowable Module Surface Temperatures
51
600 DC Power Requirements
53
Table 20. Input Voltage
53
Power Supply Current, Average, and Peak
54
Table 21. Model 147GB
54
Table 22. Model 147GB: 5V Current During Spinup
54
Table 23. Model 147GB: 12V Current During Spinup
55
Ripple Voltage
56
Table 24. Model 73GB
56
Table 25. Model 36GB
56
Table 26. Power Supply Generated Ripple at Drive Power Connector
56
Power Consumption Efficiency Index
57
Table 27. Power Consumption Efficiency Index
57
10 Reliability
59
Start/Stop Cycles
59
Data Reliability
59
Seek Errors
59
Failure Prediction (PFA/S.M.A.R.T)
59
Preventive Maintenance
59
Temperature Warning
59
11 Mechanical Specifications
61
Outline
61
Mechanical Dimensions
62
Table 28. Physical Dimensions
62
Interface Connector
63
And 80 Pin Connectors
63
Mounting Positions and Tappings
64
Drive Mounting
66
Heads Unload and Actuator Lock
66
Breather Hole
66
12 Vibration and Shock
67
Operating Vibration
67
Random Vibration
67
Swept Sine Vibration
67
Non-Operating Vibration
67
Operating Shock
67
Non-Operating Shock
68
Half Sinewave Shock Pulse
68
Rotational Shock
68
13 Acoustics
69
Sound Power Levels
69
Table 29. A-Weighted Sound Power Levels
69
14 Identification
71
Labels
71
15 Standards
73
UL and CSA Standard Conformity
73
European Standards Compliance
73
German Safety Mark
73
Flammability
73
Corporate Standards Compliance
73
16 Electromagnetic Compatibility
75
17 SCSI Command Set
77
Table 107. PRE-FETCH (34)
77
Table 109. READ (10) - (28)
77
Table 114. READ CAPACITY (25)
77
Table 116. READ DEFECT DATA (37)
77
Table 30. SCSI Commands Supported
77
Table 37. INQUIRY (12)
77
Table 47. Log Sense (4D)
77
Table 67. Mode Select (15)
77
Table 68. Mode Select (55)
77
Table 154. SYNCHRONIZE CACHE (35)
78
Table 165. WRITE same (41)
78
Table 166. Write same (16) - (93)
78
Abbreviations
79
Byte Ordering Conventions
79
SCSI Control Byte
79
Table 31. SCSI Control Byte
79
Format Unit (04)
80
Table 32. FORMAT UNIT (04)
80
Defect List
82
Table 33. Format of Defect List Header
82
Defect Descriptor
83
Table 34. Defect Descriptor - Block Format (for N + 1 Defects)
83
Table 35. Defect Descriptor - Bytes from Index Format (for N = 1 Defects)
84
Table 36. Defect Descriptor - Physical Sector Format (for N + 1 Defects)
85
Inquiry (12)
86
Table 38. Page Code Descriptions
86
Inquiry Data
87
Table 39. Inquiry Data Format - EVPD = 0, Page Code = 0
87
Table 40. Inquiry Data - EVPD = 1 (Page Code = 00H)
88
Table 41. Inquiry Data - EVPD = 1 (Page Code = 03H)
90
Table 42. Inquiry Data - EVPD = 1 (Page Code = 80H)
92
Table 43. Inquiry Data - EVPD = 1 (Page Code = 83H)
93
Table 44. Inquiry Data - EVPD = 1 (Page Code = D1H)
94
Table 45. Inquiry Data - EVPD = 1 (Page Code = D2H)
95
Log Select (4C)
96
Table 46. Log Select (4C)
96
Log Sense (4D)
99
Log
100
Log Sense
101
Log Sense
102
Table 49. Log Sense Page 2 (Part 1 of 2)
102
Table 50. Log Sense Page 2 (Part 2 of 2)
103
Log Sense
104
Table 51. Log Sense Page 3 (Part 1 of 2)
104
Table 52. Log Sense Page 3 (Part 2 of 2)
105
Log Sense
106
Table 53. Log Sense Page 5 (Part 1 of 2)
106
Table 54. Log Sense Page 5 (Part 2 of 2)
107
Log Sense
108
Log Sense
109
Log Sense
110
Log Sense
111
Table 59. Log Sense Page F, Application Client Log
111
Log Sense
112
Table 48. Log Sense
112
Table 55. Log Sense
112
Table 60. Log Sense
112
Table 61. Log Sense Page 10, Self-Test Results
112
Table 62. Log Sense Page 10, Self-Test Results
113
Table 63. Log Sense Page 10, Extended Segment Number
114
Log Sense Page 2F
115
Table 64. Log Sense Page 2F
115
Log Sense
116
Table 56. Log Sense
116
Table 65. Log Sense
116
Log Sense
119
Table 57. Log Sense
119
Table 58. Log Sense
119
Table 66. Log Sense
119
Mode Select (15)
121
Mode Select (55)
122
Mode Sense (1A)
123
Table 69. Mode Sense (1A)
123
Table 70. Page Code Usage
124
Mode Parameter List
125
Table 71. Mode Parameter Header (6)
125
Table 72. Mode Parameter Header (10)
125
Table 73. Mode Parameter Block Descriptor
127
Page Descriptor
128
Table 74: Mode Parameter Page Format
128
Table 75: Supported Page Codes
128
Mode Page 00 (Vendor Unique Parameters)
129
Table 76. Vendor Unique Parameters
129
Mode Page 01 (Read/Write Error Recovery Parameters)
132
Table 77. Mode Page 01 (Vendor Unique Parameters)
132
Mode Page 02 (Disconnect/Reconnect Parameters)
137
Table 78. Mode Page 02 (Disconnect/Reconnect Parameters)
137
Mode Page 03 (Format Device Parameters)
139
Table 79. Mode Page 03 (Format Device Parameters)
139
Mode Page 04 (Rigid Disk Drive Geometry Parameters)
141
Table 80. Mode Page 04 (Rigid Disk Drive Geometry Parameters)
141
Mode Page 07 (Verify Error Recovery Parameters)
142
Table 81. Mode Page 07 (Verify Error Recovery Parameters)
142
Mode Page 08 (Caching Parameters)
143
Table 82. Page 08 (Caching Parameters)
143
Mode Page 0A (Control Mode
146
Table 83. Page 0A (Control Mode
146
Mode Page 0C (Notch Parameters)
148
Table 84. Page 0C (Notch Parameters)
148
Mode Page 19 (Port Control Parameters)
150
Table 85. Short (Port Control Parameters) Short Format
150
Table 86. Page 19 (Port Control Parameters) Long Format
151
Table 87. Margin Control Subpage
152
Table 88. Saved Training Configuration Subpage
153
Table 89. Negotiated Settings Subpage
154
Table 90. Report Transfer Capabilities Subpage
155
Mode Page 1A (Power Control)
156
Table 91. Page 1A (Power Control)
156
Mode Page 1C (Informational Exceptions Control)
157
Table 92. Page 1C (Informational Exceptions Control)
157
Mode Sense (5A)
159
Table 93. Mode Sense (5A)
159
Persistent Reserve in (5E)
161
Service Action
161
Table 94. Persistent Reserve in (5E)
161
Table 95. PERSISTENT RESERVE IN, Service Action Codes
161
Parameter Data for Read Keys
162
Table 96. PERSISTENT RESERVE IN, Parameter Data for Read Keys
162
Parameter Data for Read Reservations
163
Table 97. PERSISTENT RESERVE IN, Parameter Data for Read Reservations
163
Table 98. PERSISTENT RESERVE IN, Read Reservation Descriptor
164
Persistent Reserve out (5F)
165
Table 99. PERSISTENT RESERVE out (5F)
165
Service Action
166
Table 100. PERSISTENT RESERVE OUT, Service Action Code
166
Scope
169
Table 101. PERSISTENT RESERVE OUT, Scope Code
169
Table 102. PERSISTENT RESERVE OUT, Type Code
169
Type
169
Table 103. Conflict between New and Existing Persistent Reserve
170
Parameter List
171
Summary
171
Table 104. PERSISTENT RESERVE OUT, Parameter List
171
Table 105. PERSISTENT RESERVE OUT, Service Action, Parameters and Generation Counter
171
Table 106. APTPL and Information Held by a Drive
172
Pre-Fetch (34)
173
Read (6) - (08)
174
Table 108. READ (6) - (08)
174
Read (10) - (28)
175
Read Buffer (3C)
176
Table 110. READ BUFFER (3C)
176
Combined Header and Data (Mode 00000B)
177
Read Data (Mode 00010B)
177
Table 111. Read Buffer Header
177
Descriptor (Mode 00011B)
178
Table 112. Read Buffer Description
178
Echo Buffer Descriptor (Mode 01011B)
179
Enable Expander Communications Protocol and Echo Buffer (Mode 11010B)
179
Read Data from Echo Buffer (Mode 01010B)
179
Table 113. Echo Buffer Descriptor
179
Read Capacity (25)
180
Returned Data Format
181
Table 115. Format of READ CAPACITY Command Reply
181
Read Defect Data (37)
182
Table 117. Defect List Format
183
Defect List Descriptor
184
Defect List Header
184
Table 118. Defect List Header
184
Table 119. Defect List Descriptor
184
Bytes from Index Format (100B)
185
Physical Sector Format (101B)
185
Table 120. Defect Descriptors of Bytes from Index Format
185
Table 121. Defect Descriptors of Physical Sector Format
185
Read Defect Data (B7)
186
Defect List Header
186
Table 122. READ DEFECT DATA (B7)
186
Table 123. Defect List Header
186
Defect List Descriptor
187
Bytes from Index Format (100B)
187
Physical Sector Format (101B)
187
Table 124. Defect List Descriptor
187
Table 125. Defect Descriptors of Bytes from Index Format
187
Table 126. Defect Descriptors of Physical Sector Format
187
Read Long (3E)
188
Table 127. READ LONG (3E)
188
Reassign Blocks (07)
189
Table 128. REASSIGN BLOCKS (07)
189
Table 129. Format of Reassign Blocks Data
190
Receive Diagnostics Results (1C)
191
Receive Diagnostic Results
191
Table 130. RECEIVE DIAGNOSTIC RESULTS (1C)
191
Table 131. Receive Diagnostic Results
191
Receive Diagnostic Results
192
Table 132. Receive Diagnostic Results
192
Table 133. Translated Address
192
Release (17)
193
Release (57)
194
Report Device Identifier (A3)
195
Table 136. REPORT DEVICE IDENTIFIER (A3)
195
Table 137. Report Device Identifier Parameter List
196
Report Luns (A0)
197
Table 138. REPORT LUNS (A0)
197
Table 139. LUN Reporting Parameter List Format
197
Request Sense (03)
198
Table 140. REQUEST SENSE (03)
198
Reserve (16)
199
Reserve (56)
200
Rezero Unit (01)
201
Seek (6) - (0B)
202
Table 144. SEEK (6) - (0B)
202
Seek (10) - (2B)
203
Table 145. SEEK (10) - (2B)
203
Send Diagnostic (1D)
204
Table 146. SEND DIAGNOSTIC (1D)
204
Table 147. SEND DIAGNOSTIC Function Code (1D)
205
Send Diagnostic
206
Table 148. Diagnostic
206
Table 149. Diagnostic
206
Table 150. Address to Translate
207
Set Device Identifier (A4)
208
Table 151. SET DEVICE IDENTIFIER (A4)
208
Table 152. SET DEVICE IDENTIFIER, Parameter List
208
Start Stop Unit (1B)
209
Table 153. START STOP UNIT (1B)
209
Synchronize Cache (35)
210
Table 155. TEST UNIT READY (00)
211
Test Unit Ready (00)
211
Table 156. VERIFY (2F)
212
Verify (2F)
212
Table 157. Write (16) - (8F)
213
Verify (16) - (8F)
213
Table 158. WRITE (6) - (0A)
214
Write (6) - (0A)
214
Table 159. WRITE (10) - (2A)
215
Write (10) - (2A)
215
Table 160. Write and Verify (8E)
216
Write and Verify (16) - (8E)
216
Table 161. WRITE and VERIFY (2E)
217
Write and Verify (2E)
217
Write Buffer (3B)
218
Table 162. WRITE BUFFER (3B)
218
Combined Header and Data (Mode 00000B)
219
Table 163. Write Buffer Header
219
Write Data (Mode 00010B)
219
Download Microcode (Mode 00100B)
220
Download Microcode and Save (Mode 00101B) -Single Binary File
220
Download Microprocessor Microcode and Save (Mode 00111B) - Multiple Binary Files
221
Enable Expander Communications Protocol (Mode 11010B)
221
Write Data to Echo Buffer (Mode 01010B)
221
Table 164. WRITE LONG (3F)
222
Write Long (3F)
222
Write same (41)
223
Write same (16) - (93)
224
18 SCSI Status Byte
225
Table 167. SCSI Status Byte. Format of the SCSI STATUS Byte
225
19 SCSI Message System
227
Supported Messages
228
Task Complete (00)
228
Synchronous Data Transfer Request (01, 03, 01H)
229
Table 168. Synchronous Data Transfer Request
229
Table 169. Initiator Request/Target Response (LVD Mode)
230
Table 170. Initiator Request/Target Response (SE Mode)
231
Table 171. Target Response to Initiator's Transfer Period (LVD Mode)
232
Wide Data Transfer Request (01, 02, 03H)
233
Table 172. Target Response to Initiator's Transfer Period (SE Mode)
233
Table 173. Wide Data Transfer Request
234
Table 174. Initiator Request/Target Response
234
Parallel Protocol Request (01, 06, 04H)
235
Table 175. Target Request to Initiator
235
Table 176. Parallel Protocol Request
235
Table 177. Initiator Request/Target Response (DT_REQ = 1, IU_REQ = 1)
236
Table 178. Initiator Request/Target Response (DT_REQ = 1, IU_REQ = 0)
236
Table 179. Initiator Request/Target Response (DT_REQ = 0, IU_REQ = 0)
236
Save Data Pointer (02)
237
Restore Pointers (03)
237
Table 180. Bit Position Table for Byte 7 of Parallel Protocol Request
237
Disconnect (04)
238
Initiator Detected Error (05)
238
Abort Task Set (06)
238
Message Reject (07)
238
No Operation (08)
238
Message Parity Error (09)
239
Linked Task Complete (0A)
239
Linked Task Complete with Flag (0B)
239
Target Reset (0C)
239
Abort Task (0D)
239
Clear Task Set (0E)
239
Logical Unit Reset (17)
239
Queue Tag Messages (20H, 21H, 22H)
240
Ignore Wide Residue
240
Table 181. Queue Tag Messages
240
Table 182. Ignore Wide Residue Message Format
240
Identify (80 - FF)
241
Supported Message Functions
242
Attention Condition
243
20 Additional Information
245
SCSI Protocol
245
Priority of SCSI Status Byte Reporting
245
Invalid LUN in Identify Message
245
Incorrect Initiator Connection
246
Command Processing During Execution of Active I/O Process
246
Unit Attention Condition
248
Command Processing During Startup and Format Operations
249
Internal Error Condition
249
Deferred Error Condition
249
Degraded Mode
250
Table 183. Spindle Motor Degraded Mode - Disable Auto Start
250
Table 184. Spindle Motor Degraded Mode - Auto Start Delay/Spinning up
252
Table 185. Spindle Motor Degraded Mode - Spindle Start Failure
253
Table 187. Self Configuration Failure Degraded Mode
255
Table 188. Format Command Failure Degraded Mode
256
Command Processing While Reserved
257
Priority Commands
257
Command Queuing
258
Queue Depth
258
Tagged Queuing
258
Untagged Queuing
258
Command Queuing Rule
258
Queue Full Status
258
Device Behavior on Command Queuing
258
Command Reordering
259
Concurrent I/O Process
259
Write Cache
259
Automatic Rewrite/Reallocate
260
Table 189. Sense Data Combinations with Auto/Recommend Rewrite/Reallocate
261
Segmented Caching
262
Overview
262
Read Ahead
262
Multiple Initiator Systems
262
Sense Data
262
Mode
262
Reselection Time-Out
262
Single Initiator Selection
262
Non-Arbitrating Systems
262
Selection Without ATN
263
Multiple Initiator Environment
263
Initiator Sense Data
263
Initiator Mode Select/Mode Sense Parameters
263
Initiator Data Transfer Mode Parameter
263
Contingent Allegiance Condition
263
Reset
263
Reset Sources
264
Reset Actions
264
Diagnostics
264
Power on Diagnostics
264
Self-Test Via SEND DIAGNOSTIC Command
265
Table 190. Short and Extended Self-Test Description
266
Idle Time Function
268
Command Time out Limits
268
Reassignment Time
268
Format Time
268
Start/Unit Stop Time
268
Medium Access Command Time
269
Time-Out Limits for Other Commands
269
Recommended Initiator ERP
270
Drive Service Strategy
270
Recommendations for System Error Log
271
Data Recovery Procedure
271
Table 191. Recommend Reassign Errors
272
Table 192. Log Only Errors
272
Data Error Logging
272
Nondata Error Recovery Procedure
273
Predictive Failure Analysis
278
21 SCSI Sense Data
279
SCSI Sense Data Format
279
Table 193. Format of Sense Data
279
Sense Data Description
280
Valid (Bit 7 of Byte 0)
280
Error Code (Bit 6 - 0 of Byte 0)
280
ILI: Incorrect Length Indicator (Bit 5 of Byte 2)
280
Sense Key (Bit 3 - 0 of Byte 2)
281
Information Bytes (Byte 3 through 6)
282
Additional Sense Length (Byte 7)
282
Command Specific Information (Byte 8 through 11)
282
Additional Sense Code/Qualifier (Byte 12 and 13)
283
RU: Field Replaceable Unit (Byte 14)
299
Sense Key Specific (Byte 15 through 17)
299
Table 194. Field Pointer Bytes
299
Table 195. Actual Retry Count
300
Reserved (Byte 18 through 19)
301
Vendor Unique Error Information (Byte 20 through 23)
301
Table 196. Progress Indication
301
Table 197. Unit Error Codes List
303
Advertisement
Hitachi HUS151414VL3800 Quick Installation Manual (5 pages)
Hitachi Ultrastar 15K147: Install Guide
Brand:
Hitachi
| Category:
Storage
| Size: 0.07 MB
Table of Contents
Handling Precautions
1
Installing the Drive
1
Address Jumper and Drive Option Blocks
2
Mounting Orientation
3
Special Notes
4
Advertisement
Related Products
Hitachi HUS151473VL3800 - Ultrastar 73.4 GB Hard Drive
Hitachi HUS151414VL3600
Hitachi HUS151473VL3600
Hitachi HUS151436VL3600
Hitachi HUS151436VL3800
Hitachi ULTRASTAR 15K450 HUS154530VLF400
Hitachi ULTRASTAR 15K450 HUS154545VLF400
Hitachi HUS157336EL3600
Hitachi HUS157373EL3600
Hitachi HUS157373EL3800
Hitachi Categories
Projector
Air Conditioner
Drill
Power Tool
TV
More Hitachi Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL