Sign In
Upload
Manuals
Brands
HP Manuals
Measuring Instruments
8510
User Manuals: HP 8510 Network Analyzer
Manuals and User Guides for HP 8510 Network Analyzer. We have
1
HP 8510 Network Analyzer manual available for free PDF download: User Manual
HP 8510 User Manual (73 pages)
Pulsed-RF Network Analyzer
Brand:
HP
| Category:
Measuring Instruments
| Size: 0.88 MB
Table of Contents
Table of Contents
6
Introduction
10
Organization of this Document
10
System Description
10
Principles of Pulsed-RF Network Measurements
10
Pulse Measurements Overview
10
Operating the HP 8510 for Pulsed-RF Measurements
10
Frequency Domain Point-In-Pulse Measurements
11
Pulse Pro Le Domain Measurements
11
General Timing Information
11
Using External Triggering and Pulse Modulation
11
High Power Measurements
11
Reference Data
11
HP 8510 Pulsed-RF Network Analyzer System
12
System Description
14
Who Should Make Pulsed-RF Measurements
14
Theory of Operation
15
Test Set Signal Flow
16
HP 85110A S-Parameter Test Set Signal Flow
17
Principles of Pulsed-RF Network Measurements
18
Pulse Repetition Period, PRP
18
Pulse Repetition Frequency, PRF
18
Duty Cycle
19
Pulse Width
19
Rise/Fall Time
19
Trigger Delay
19
Pulse Pro Le Measurement Resolution Period
20
Pulse Measurements Overview
22
Pulsed-RF S-Parameters Versus Frequency
22
Pulse Pro Le Domain
24
Operating the HP 8510 for Pulsed-RF Measurements
26
System Connections
26
System Cable Connections
27
Turn on System Power
28
Load Pulse Hardware State and Instrument State Files
28
Srce. on
29
Operator's Check
30
Pulse Pro Le Domain Check
30
Frequency Domain Check
32
External Triggering Check
34
Frequency Domain Point-In-Pulse Measurements
36
Measurement Calibration for Point-In-Pulse
36
Measurement
36
Set Pulse Polarity
36
Set Pulse Width
37
Set Duty Cycle Limit
37
Set Trigger Delay
37
Connect the Device under Test
37
Pulse Pro Le Domain Measurements
40
Measurement Calibration for Pulse Pro Le
40
Pulse Pro Le Domain
40
Frequency Domain Using Frequency List
41
Frequency List Display During Measurement Calibration
42
Measurement
43
Set Pulse Polarity
43
Set Pulse Width
44
Set Duty Cycle Limit
44
Set Measurement Time Span
44
Set Measurement Resolution Period
44
Connect the Device under Test
44
Minimum Time Span, Resolution Period = 100 Ns
45
Switching between Frequency Domain and Pulse Pro Le Domain
46
General Timing Information
48
Network Analyzer Measurement Cycle
48
Network Analyzer Measurement Cycle
49
Measurement Cycle Time
50
Sweep Time
50
Pulse Width
50
Duty Cycle Limit
50
Pulse Pro Le Domain Stop Time
50
Frequency Domain Trigger Delay
50
Pulse Repetition Period and Duty Cycle Considerations
51
External Trigger and Stop Sweep Signals
52
Using External Triggering and Pulse Modulation
54
Connect the Pulse Generator
54
External Control of PRP and Duty Cycle
55
Duty Cycle = 50%
56
High Power Measurements
58
Signal Level Characteristics
58
Connecting External Signal Conditioning
59
Example High Power Measurements
60
Measure a 30 Db Ampli er
60
Measure an Ampli er with High Input Levels
61
Using the Port 1 and Port 2 Attenuators
62
Controlling the Attenuators
62
Measure User Parameters and Set Attenuators
62
Changing Signal Path after Calibration
63
Set the Attenuators
63
Store Trace Memories
63
View the Normalized Parameters
64
Selecting the Appropriate Measurement Calibration
64
General Calibration and Measurement Sequence
66
General Calibration and Measurement Sequence Using Display Math
66
Reference Data
68
Creating Pulse Hardware State and Instrument State Files
68
Pulse Menus
69
Pulse con Guration Menu
69
Pulse Out: High
69
Pulse Out: Low
69
Trigger Delay
70
Trig Mode: Internal
70
Trig Mode: External
70
HP 8510 Option 008 Added Programming Codes
71
HP 8510 Option 008 Added Query Commands
71
Option 008 Domain, Stimulus, and System Menus
72
Advertisement
Advertisement
Related Products
HP 85106D
HP 85108A
HP 85108
HP 8510A
HP 8510B
HP 8510C
HP 8591C
HP 8509B
HP 8557A
HP 8558B
HP Categories
Desktop
Laptop
Server
Monitor
Switch
More HP Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL