• Please use approved power cord provided by Philips at all times. If your power cord is missing, please 1.1 Safety precautions and contact your local service center.
Page 4
1. Important • Do not knock or drop the monitor • Unplug the monitor if you are not during operation or transportation. going to use it for an extensive period of time. • The USB Type-C port could only be connected to specify equipment • Unplug the monitor if you need to with fire enclosure in compliance...
1. Important known as “after-imaging” or “ghost 1.2 Notational Descriptions imaging”, on your screen. The following subsections describe • “Burn-in”, “after-imaging”, or notational conventions used in this “ghost imaging” is a well-known document. phenomenon in LCD panel technology. In most cases, the Notes, Cautions and Warnings “burn-in”...
From the planning, design and production stages, Philips emphasizes the important of making products that can easily be recycled. At Philips, end- of-life management primarily entails participation in national take-back This marking on the product or on...
Top Victory Investments Ltd., and Top Victory Investments Ltd. is the warrantor in (2) Use your fingers to tighten the relation to this product. Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N.V. and are used under license.
Page 8
HDD, for example. The display must be powered ON at all times to be able to use this function. Some select Philips displays may not Power or Charge your device when it enters to “Sleep/Standby” mode (White...
2. Setting up the monitor please enter to OSD Menu and select 2.2 Operating the monitor “USB Standby Mode”, then, turn the function to “ON” mode (default=OFF). Description of the control buttons This will then keep the USB power and charging functions active even when the monitor is in sleep/standby mode.
Page 10
0, 1, 2, 3, 4 What is On-Screen Display (OSD)? LowBlue Mode 1, 2, 3, 4 On-Screen Display (OSD) is a feature in all Philips LCD monitors. It allows an Input end user to adjust screen performance HDMI 1.4 DisplayPort...
Page 11
2. Setting up the monitor Resolution notification Height adjustment This monitor is designed for optimal performance at its native resolution, 1920 x 1080 @ 60 Hz. When the monitor is powered on at a different resolution, an alert is displayed on screen: Use 1920 x 1080 for best results.
2. Setting up the monitor Note 2.3 Remove the Base Assembly This monitor accepts a 100mm x 100mm for VESA Mounting VESA-Compliant mounting interface. Before you start disassembling the VESA Mounting Screw M4. Always monitor base, please follow the contact manufacturer for wall-mount instructions below to avoid any possible installation.
How does it work? SmartImage is an exclusive, leading edge Philips technology that analyzes the content displayed on your screen. • EasyRead: Helps improve reading Based on a scenario you select, of text based application like PDF SmartImage dynamically enhances the ebooks.
Developed for wellbeing, Philips LowBlue Mode setting uses a smart software technology to reduce harmful shortwave blue light. • Off: No optimization by SmartImage.
5. PowerSensor™ detection signal for distances up to 5. PowerSensor™ 120 cm or 47 inches. (Setting 4) • Since some dark colored clothing How does it work? tends to absorb infrared signals even when the user is within 100 cm • PowerSensor works on principle or 40 inches of the display, step up of transmission and reception of...
Page 17
5. PowerSensor™ Note A manually selected PowerSensor mode will remain operational unless and until it is readjusted or the default mode is recalled. If you find that the PowerSensor is excessively sensitive to nearby motion for some reason, please adjust to a lower signal strength. Keep sensor lens clean, if the sensor lens is dirty, wipe it with alcohol to avoid reducing of distance detection .
6.Technical Specifications 6. Technical Specifications Picture/Display Monitor Panel Type IPS Technology Backlight W-LED Panel Size 27" W (68.6 cm) Aspect Ratio 16:9 Pixel Pitch 0.3114 (H) mm x 0.3114 (V) mm Contrast Ratio(typ.) 1000:1 Optimum Resolution 1920 x 1080 @ 60 Hz Viewing Angle 178°...
Page 19
6.Technical Specifications Other Convenience VESA mount (100 x 100 mm), Kensington Lock Plug & Play Compatibility DDC/CI, sRGB, Windows 10/8.1/8/7, Mac OS X Stand Tilt -5 / +30 degree Swivel -175 / +175 degree Height adjustment 150 mm Pivot -90 / +90 degree Power AC Input AC Input...
Page 20
500 to 1060hPa (Non-operation) Environmental and energy ROHS Packaging 100% recyclable Specific Substances 100% PVC BFR free housing Cabinet Color Black Finish Texture Note This data is subject to change without notice. Go to www.philips.com/support to download the latest version of leaflet.
7.Power Management 7. Power Management If you have VESA DPM compliance display card or software installed in your PC, the monitor can automatically reduce its power consumption when not in use. If an input from a keyboard, mouse or other input device is detected, the monitor will 'wake up' automatically.
Pixel Defect Policy single black pixel. Other combinations of lit and dark sub pixels appear as Philips strives to deliver the highest single pixels of other colors. quality products. We use some of the industry's most advanced...
Page 24
Black Dot Defects the warranty period, a TFT Monitor Black dot defects appear as pixels or panel in a Philips flat panel monitor sub pixels that are always dark or 'off'. must have pixel or sub pixel defects That is, a dark dot is a sub-pixel that...
Page 25
8.Customer care and warranty BRIGHT DOT DEFECTS ACCEPTABLE LEVEL 1 lit subpixel 2 adjacent lit subpixels 3 adjacent lit subpixels (one white pixel) Distance between two bright dot defects* >15mm Total bright dot defects of all types BLACK DOT DEFECTS ACCEPTABLE LEVEL 1 dark subpixel 5 or fewer...
Please contact our Philips Customer Service Representative or local contact center (by Consumer care number) for more details. Philips Customer Care Center number listed below.
“burn-in”, also Service contact information listed in known as “after-imaging “ or “ghost Important information manual and imaging”, on your screen. “burn-in”, contact Philips customer service “after-imaging”, or “ghost imaging” representative. is a well-known phenomenon in * Functionality different according to monitor panel technology.
Page 29
• Shut down your computer, subjected to excessive shocks disconnect your old monitor and and is protected from sharp or reconnect your Philips LCD monitor. blunt objects. When handling the • Turn on your monitor and then turn monitor, make sure that there is on your PC.
Page 30
PC, workstation or Mac? Failure to activate a screen saver, or a periodic screen refresh application Ans.: Yes. All Philips LCD monitors are may result in severe “burn-in” or “after- fully compatible with standard image” or “ghost image” symptoms PCs, Macs and workstations.
Page 31
Q14: Where can I find Important Information manual mentioned in EDFU? Ans.: Important Information manual can be download on the Philips website support page.
Page 32
This product has been manufactured by and is sold under the responsibility of Top Victory Investments Ltd., and Top Victory Investments Ltd. is the warrantor in relation to this product. Philips and the Philips Shield Emblem are regis- tered trademarks of Koninklijke Philips N.V. and are used under license.
Need help?
Do you have a question about the 273B9 and is the answer not in the manual?
Questions and answers