MN1-6127 Rev.3 Introduction This is the instruction manual for L44K probe. The probe is available by connecting to Hitachi’s ultrasound diagnostic instrument and can be mainly used for observation of human internal organs during surgery. Prior to use, read this manual as well as the separate instruction manual “Safety” in which information for safe use is provided.
MN1-6127 Rev.3 CONTENTS 1. General Information ...........................1 1-1. Intended use ...................................1 1-2. Classification of ME equipment ............................1 1-3. Standard components ..............................1 2. Specifications and Parts name ........................3 2-1. Specifications .................................3 2-2. Name of each parts ................................4 3. Preparations before use ..........................5 3-1.
• Operation mode ....................Continuous operation • Method of sterilization ..................Refer to the separate instruction manual “Cleaning, Disinfection and Sterilization” 1-3. Standard components The standard components of L44K probe are as follows. L44K Probe ··························································· 1 pc Storage case ··························································· 1 pc Instruction Manual •...
At the time of publication of this manual, the connectable diagnostic ultrasound instrument or instrument software version available with this probe is different for each country, please refer to the instrument instruction manual or contact your local Hitachi representative. Field of view: 42mm Frequency: 7.5 MHz...
MN1-6127 Rev.3 2-2. Name of each parts The name of each part is shown in Figure 2 and the explanation for each part is listed in Table 3. Cable Probe tip Front mark Transducer center mark Transducer position mark Connector Ultrasound radiation part Figure 2 Name of each parts Table 1 Name of each part and its explanation...
MN1-6127 Rev.3 3. Preparations before use This chapter describes preparations needed to use the probe safely. Please prepare the probe prior to each use by following the instructions below. 3-1. Visual check Visually check the probe tip, ultrasonic radiation part, cable, and connector. If any holes, indentations, abrasion, cracks, deformation, looseness, discoloration, or other abnormalities are found, do not use the probe.
MN1-6127 Rev.3 4. Operation This chapter describes the operation of the probe. 4-1. Operation Place the ultrasonic radiation part of the probe onto the organ surface during surgery. An image of the region of interest is displayed on the monitor of the ultrasound diagnostic instrument. For details on displaying and adjusting the image, refer to the documentation supplied with the ultrasound diagnostic instrument.
Page 12
+81-3-6284-3668 http://www.hitachi.com/businesses/healthcare/index.html Overseas Offices: Hitachi Medical Systems GmbH Otto-von-Guericke-Ring 3 D-65205 Wiesbaden, Germany EU Importer: Hitachi Medical Systems Europe Holding AG Address: Sumpfstrasse 13 CH-6300 Zug, Switzerland US Importer: Hitachi Healthcare Americas Corporation Address: 1959 Summit Commerce Park, Twinsburg, Ohio 44087 Distributor MN1-6127 Rev.